Thermal condition monitoring device
K6PM-TH
Continuously monitor and analyze the
temperature of critical components
using thermal imaging technology
•
DIN-rail mount controller with built-in temperature display and
alarms
•
Reduce setup and analysis time with built-in temperature
algorithms
•
Connect controller to a PC and monitor thermal conditions with
included Thermal Condition Monitoring Software
For the most recent information on models that have been certified
for safety standards, refer to your Omron website.
System Configuration
With the software tool, a maximum of five K6PM-THMD devices can be connected via an Ethernet cable, and settings and monitoring can be
performed.
Software tool
Industrial switching hub (e.g., W4S1)
Constantly connect
with PC or PLC to
enable the monitoring
of temperature status.
Ethernet
Ethernet
Ethernet
K6PM-THMD
RS-485
31 Units
max.
5 Units max.
RS-485
31 Units
max.
K6PM-THS
Note:
Only when setting the IP address, connect the PC and the K6PM-THMD device one to one with an Ethernet cable as shown below.
Software tool
Ethernet
One-to-one
connection
K6PM-THMD
1
K6PM-TH
Model Number Structure
Model Number Legend
Main Unit
K6PM- TH MD - EIP
(1)
No.
(2)
(3)
Symbol
Meaning
Classification
(1)
(2)
(3)
Product classification
Product classification
Communications method
TH
MD
EIP
Thermal condition monitoring device
Main Unit
Supports EtherNet/IP and Modbus TCP communications
Thermal Imaging Sensor
K6PM- TH S 3232
(1) (2)
No.
(3)
Symbol
Meaning
Classification
(1)
(2)
(3)
Product classification
Product classification
Model classification
TH
S
3232
Thermal condition monitoring device
Infrared thermal sensor (Special thermal imaging sensor)
Number of K6PM sensor pixels: 32 × 32
2
K6PM-TH
Ordering Information
Main Unit
Power supply voltage
24 VCD
Model
K6PM-THMD-EIP
Thermal Imaging Sensor
Resolution
32 × 32
Model
K6PM-THS3232
EtherNet/IP communications cable recommended parts
Use a Category 5 or higher STP cable (shielded twisted pair cable).
Cable with Connectors
Item
Cable with Connectors on Both Ends
(RJ45/RJ45)
Standard RJ45 plug type
*1
Cable color: Yellow
*3
Recommended
manufacturer
Cable length (m)
0.3
0.5
OMRON
1
2
3
5
Cable with Connectors on Both Ends
(RJ45/RJ45)
Rugged RJ45 plug type
*1
Cable color: Light blue
0.3
0.5
OMRON
1
2
5
10
Model
XS6W-6LSZH8SS30CM-Y
XS6W-6LSZH8SS50CM-Y
XS6W-6LSZH8SS100CM-Y
XS6W-6LSZH8SS200CM-Y
XS6W-6LSZH8SS300CM-Y
XS6W-6LSZH8SS500CM-Y
XS5W-T421-AMD-K
XS5W-T421-BMD-K
XS5W-T421-CMD-K
XS5W-T421-DMD-K
XS5W-T421-GMD-K
XS5W-T421-JMD-K
Wire Gauge and Number of Pairs:
AWG26, 4-pair Cable
Cable Sheath material: LSZH
*2
Wire Gauge and Number of Pairs:
AWG22, 2-pair Cable
*1.
Cables with standard RJ45 plugs are available in the following lengths: 0.2 m, 0.3 m, 0.5 m, 1 m, 1.5 m, 2 m, 3 m, 5 m, 7.5 m, 10 m, 15 m, 20 m.
Cables with rugged RJ45 plugs are available in the following lengths: 0.3 m, 0.5 m, 1 m, 2 m, 3 m, 5 m, 10 m, 15 m.
For details, refer to the
Industrial Ethernet Connectors Catalog
(Cat. No. G019).
*2.
The lineup features Low Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use.
*3.
Cable colors are available in yellow, green, and blue. The last character of the model changes to "-G" or "-B".
Cable/Connector
Part name
Cable
RJ45 connector
Manufacturer
Hitachi Metals, Ltd.
Panduit Corporation
MPS588-C
*
Model
NETSTAR-C5E SA 0.5 × 4P
*
*
It is recommended to use the cable and connector in combination described above.
Industrial switching hub (recommended parts)
Specifications
Recommended manufacturer
Appearance
Function
No. of ports
Failure
detection
function
Model
OMRON
Packet priority control (QoS): EtherNet/IP control
data priority
Failure detection: Broadcast storm,
LSI failure detection
10/100BASE-TX, Auto-Negotiation
3
Not possible
W4S1-03B
5
5
Not possible
Possible
W4S1-05B
W4S1-05C
Cisco Systems, Inc
Contec USA, Inc.
Phoenix Contact USA
Consult the manufacturer.
https://www.cisco.com/
Consult the manufacturer.
https://www.contec.com/us/
Consult the manufacturer.
https://www.phoenixcontact.com/online/portal/pc
3
K6PM-TH
Ratings and Characteristics
Main Unit Specifications
Ratings
Item
Power supply voltage
Power supply
Allowable operating voltage range
Power supply frequency range
Power consumption
Input
Compatible sensor
Number of connected K6PM sensors
Output form
Output
Number of outputs
Rated voltage
Maximum current
Ambient operating temperature
Ambient storage temperature
Ambient operating humidity
Storage humidity
Exterior color
Case material
Altitude
Applicable wires
Applicable wire size
Wire insertion force
Screwdriver insertion force
Wire stripping length
Recommended Flat-blade Screwdriver
Current capacity
Number of insertions
Weight
Mounting
*2
Dimensions
Setting method
Other functions
Accessories
Model
24 VDC
85% to 110% of the power supply voltage
---
1.6 W max.
K6PM-THS3232
31 units
Transistor output
3 points:
24 VDC
50 mA
-10 to +55 °C (with no condensation or freezing)
-20 to +65 °C (with no condensation or freezing)
25% to 85% (with no condensation)
25% to 85% (with no condensation)
Black
PC UL94-V0
2,000 m max.
Stranded wires, solid wires, or ferrules
0.25 to 1.5 mm
2
(AWG24 to AWG16)
8 N max. for AWG20 wire
15 N max.
8 mm
*1,
10 mm, 12 mm
XW4Z-00B
10 A (per pole)
50 times
Approx. 200 g
DIN Track mounting
Screw Mounting
45 (W) × 90 (H) × 90 (D) mm
Communications settings from software tool
Display value selection, Main Unit error and K6PM sensor error output, setting parameters
initialization, running time
Instruction manual, Software Tool (thermal condition monitoring tool) license number
K6PM-THMD-EIP
*1.
Without ferrules
*2.
For details on mounting on a DIN track and screw attachment, refer to
K6PM Thermal Condition Monitoring Device User's Manual
(H231).
4
K6PM-TH
Characteristics
Item
Temperature measurement range
Measurement temperature accuracy
Sampling cycle for the sensor
External trigger
External contact input specifications
Short circuit current
Measurement parameters
Expression method
Alarm
Number of variables
Threshold setting range
Hysteresis
Resetting method
LCD display
Display resolution
Approved standards
Applicable standards
Recommended fuse
Insulation resistance
Conforming standards
EMC
Model
K6PM-THMD-EIP
The temperature measurement range is described in the thermal sensor
(K6PM-THS3232) performance.
The measurement temperature accuracy is described in the thermal sensor (K6PM-
THS3232) performance.
Approx. 1 second/Unit
Short circuit: Residual voltage 1.5 V or less
Open: Leakage current 0.1 mA or less
Approx. 7 mA
Current temperature, differential temperature, sensor internal temperature
Transistor output, alarm bar display
Two threshold values per segment (Threshold 1 and Threshold 2)
0.0 to 999.9°C (0.0 to 999.9°F)
3.0°C width (5.4°F width)
Manual resetting
*
or automatic resetting (switching)
7-segment digital displays and individual indicators
0.1°C
UL61010-1 (Listing) installation location: Pollution level 2, South Korean Radio Law
RCM
EN61326-1 (EMI: Class A EMS: Industrial Location)
T2A, time lag, high shut-off capacity
20 M min.
Between all external terminals and the case
Between all power supply terminals and all other terminals
Between all RS-485 communications terminals, and all external trigger input terminals,
all transistor output terminals and all Ethernet ports
2,000 VAC for 1 minute
Between all external terminals and the case
Between all power supply terminals and all other terminals
Between all RS-485 communications terminals, and all external trigger input terminals,
all transistor output terminals and all Ethernet ports
Frequency: 10 to 55 Hz, 0.35-mm single amplitude in X, Y, and Z directions (10 sweeps
of 5 min each)
150 m/s
2
, 3 times each in X, Y, and Z axes, 6 directions
IP20
1 year
Alarm bar
MS and NS
Supported services
Physical layer
Transmission
specifications
Transmission speed
Transmission medium
Transmission distance
Class1
Connection resource
Ethernet
Communi
caitons
Tag data link
Packet interval (RPI)
Timeout value
Connection type
Class 3
Explicit
message
Modbus TCP
Factory
default values
UCMM
Number of clients that can communicate
at one time with UCMM
Number of clients that can be connected
simultaneously
IP address.
Subnet mask.
The default gateway.
IP address setting method
Red, yellow, and green
Red and green
EtherNet/IP (tag data link or CIP message communications)
BOOTP client
Modbus TCP
100 Base-TX
100 Mbps
Twisted pair cable (with shield: STP): Category 5 or higher
100 m max. (distance between hub and node)
Supported.
4
1,000 to 10,000 ms
Multiples of RPI (4 times, 8 times, 16 times, 32 times, 64 times, 128 times, 256 times,
512 times)
Point To Point Connection (fixed)
Supported.
Supported.
2
2
192.168.250.30
255.255.255.0
0.0.0.0
Static IP address
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Warranty period
Indicators
*
Manual resetting method: Press and hold the SEG/ALM RST Button
5