SUHNER
â
TEST+MEASUREMENT
TEST LEADS
Agilent Technologies VNAs
48
Type
50
9
SF104PB/HP3.5m/PC3.5m/570
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
22644091
SF 104PB
HP3.5-PC3.5(m)
570 mm
50
W
26.5 GHz
1.33 dB
1)
£
1.25
ü
(B)
This range of test leads has been specially devel-
oped for applications involving network analyzers
from Agilent Technologies. All test leads are pro-
vided at one end with the unit-specific, sturdy 3.5
mm or 2.4 mm connector. The
HP3.5
and
HP2.4
interfaces have a more massive thread than the
standard PC3.5 mm and PC2.4 mm interfaces.
This allows an optimal and dependable connec-
tion to be established to the measurement unit.
The
SUCOFLEX
SF 104P
and
SF 101P
test leads are
distinguished by their outstanding phase stability
and stable electrical characteristics. The test leads
are designed for frequency ranges from
26.5 GHz to 50 GHz, as a function of the connec-
tors used.
The comparatively high availability of the test
leads is ensured on the one hand by the high-preci-
sion steel connectors, and on the other hand by an
additional ruggedization of the test leads. The
ruggedization consists of a flexible stainless steel
hose in the case of the SF 104PB and of a steel
spiral with PUR jacket in the case of the SF
101PEA. It provides protection against additional
stresses such as tension and compression without
significantly affecting the ease of cable handling.
49
Type
SF104PB/HP3.5m/PC3.5m/1000
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005140
SF 104PB
HP3.5-PC3.5(m)
1000 mm
50
W
26.5 GHz
2.18 dB
1)
£
1.25
ü
(B)
50
Type
SF104PB/HP3.5m/PC3.5f/570
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
22644092
SF 104PB
HP3.5-PC3.5(f)
570 mm
50
W
26.5 GHz
1.33 dB
1)
£
1.25
ü
(B)
1)
Attenuation
values specified refer to typical values at
+25°C ambient temperature and maximum operating fre-
quency
SUHNER
®
Test+Measurement
21
SUHNER
â
TEST+MEASUREMENT
TEST LEADS
Agilent Technologies VNAs
(Cont.)
51
Type
50
9
SF104PB/HP3.5m/PC3.5f/1000
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005141
SF 104PB
HP3.5-PC3.5(f)
1000 mm
50
W
26.5 GHz
2.18 dB
1)
£
1.25
ü
(B)
54
Type
SF101PEA/HP2.4m/SKm/570
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005075
SF 101PEA
HP2.4-SK(m)
570 mm
50
W
46 GHz
4)
3.23 dB
1)
£
1.44
ü
(A, blue)
52
Type
SF101PEA/HP2.4m/PC2.4m/570
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005073
SF 101PEA
HP2.4-PC2.4(m)
570 mm
50
W
50 GHz
3.41 dB
1)
£
1.44
ü
(A, blue)
55
Type
SF101PEA/HP2.4m/SKm/570
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005076
SF101PEA
HP2.4-SK(m)
570 mm
50
W
46 GHz
4)
3.23 dB
1)
£
1.44
ü
(A, blue)
53
Type
SF101PEA/HP2.4m/PC2.4f/570
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005074
SF 101PEA
HP2.4-PC2.4(f)
570 mm
50
W
50 GHz
3.41 dB
1)
£
1.44
ü
(A, blue)
Test lead with ruggedization (armour)
The additional ruggedization offers excellent
protection against mechanical wear and tear and
environmental influences.
S
Rugged design
S
Flexible construction
S
Ideal for test laboratories and outdoor
applications
For technical information on ruggedizations of
types A and B, see page 148.
1)
Attenuation
4)
Reduced
values specified refer to typical values at +25°C ambient temperature and maximum operating frequency
frequency range due to specification of connector interface
22
SUHNER
®
Test+Measurement
SUHNER
â
TEST+MEASUREMENT
TEST LEADS
Anritsu SiteMaster
56
Type
50
9
SF104PEA/Nm/Nm/1500
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005080
SF 104PEA
2x N(m)
1500 mm
50
W
18 GHz
2.51 dB
1)
£
1.25
ü
(A, blue)
This range of test leads has been specially de-
signed for adverse outdoor applications using the
SiteMaster measurement unit series from Anritsu.
The waterproof test leads are all provided with a
ruggedization consisting of a steel spiral and a
resistant PUR jacket, which protects the coaxial
cable against mechanical stresses such as com-
pression and tension. Despite this ruggedization,
the cable remains astonishingly flexible, offering
users agreeable ease of handling.
The high electrical stability of the
SUCOFLEX
SF 104PE
and the low attenuation even with long
cable lengths are characteristics substantially sup-
porting the performance of reliable measurements
by means of the SiteMaster.
57
Type
SF104PEA/Nm/Nm/2500
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005081
SF 104PEA
2x N(m)
2500 mm
50
W
18 GHz
4.06 dB
1)
£
1.25
ü
(A, blue)
58
Type
SF104PEA/Nm/Nm/5000
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005082
SF 104PEA
2x N(m)
5000 mm
50
W
18 GHz
7.96 dB
1)
£
1.25
ü
(A, blue)
1)
Attenuation
values specified refer to typical values at
+25°C ambient temperature and maximum operating fre-
quency
SUHNER
®
Test+Measurement
23
SUHNER
â
TEST+MEASUREMENT
TEST LEADS
Anritsu SiteMaster
(Cont.)
59
Type
50
9
SF104PEA/Nm/Nf/1500
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005077
SF 104PEA
N(m) - N(f)
1500 mm
50
W
18 GHz
2.51 dB
1)
£
1.25
ü
(A, blue)
62
Type
SF104PEA/Nm/716m/1500
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
223005083
SF 104PEA
N(m) - 716(m)
1500 mm
50
W
7.5 GHz
1.51 dB
1)
£
1.25
ü
(A, blue)
60
Type
SF104PEA/Nm/Nf/2500
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005078
SF 104PEA
N(m) - N(f)
2500 mm
50
W
18 GHz
4.06 dB
1)
£
1.25
ü
(A, blue)
63
Type
SF104PEA/Nm/716f/1500
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005084
SF 104PEA
N(m) - 716(f)
1500 mm
50
W
7.5 GHz
1.51 dB
1)
£
1.25
ü
(A, blue)
61
Type
SF104PEA/Nm/Nf/5000
Item
Cable
Connector
Length
Impedance
Max. freq.
Loss
VSWR
Armour
23005079
SF 104PEA
N(m) - N(f)
5000 mm
50
W
18 GHz
7.96 dB
1)
£
1.25
ü
(A, blue)
Test lead with ruggedization (armour)
The additional ruggedization offers excellent
protection against mechanical wear and tear and
environmental influences.
S
Rugged design
S
Flexible construction
S
Ideal for test laboratories and outdoor
applications
For technical information on ruggedizations, see
page 148.
1)
Attenuation
values specified refer to typical values at +25°C ambient temperature and maximum operating frequency
24
SUHNER
®
Test+Measurement