GenSPEED
®
10,000 Category 6a Cable
Features And Benefits
■
Extensive design development
conducted to find the perfect blend of
product performance and consistent
manufacturability
■
Innovative T-Top cross-web provides
superior internal electrical characteristics
by locking the pairs into a systematic
orientation within the cable
■
Superior flame and smoke characteristics
achieved through innovative design
and careful selection of materials with
certified suppliers
■
TRU-Mark
®
print legend contains footage
markings from 1000’ to 0’
■
AirEs jacket provides superior flexibility
and maximum separation of pairs from
cable to cable for consistent PSANEXT
and PSAACRF performance
■
Made in U.S.A.
Applications
■
IEEE 802.3: 10G BASE-T, 100 BASE-T
■
100 BASE-TX, 10 BASE-T, 1000 BASE-TX
■
ANSI/TIA/EIA-854: 1000 BASE-TX
■
155 Mb/s ATM
■
ANSI X3.263: 100 Mb/s
■
IEEE 802.3af for PoE
■
IEEE 802.3at for PoE Plus
Standard Compliances
■
ANSI/TIA 568-C.2
■
NEC/CEC Type CMR (UL 1666)
for Non-Plenum
■
NEC/CEC Type CMP (NFPA 262)
for Plenum
■
RoHS Compliant Directive 2002/95/EC
■
UL 444
CONSTRUCTION
Conductors
• 23 AWG solid bare annealed copper
Insulation
• Non-Plenum: Polyolefin
• Plenum: Fluoropolymer
Color Code
• Pair 1: Blue-White
• Pair 2: Orange-White
• Pair 3: Green-White
• Pair 4: Brown-White
Separator
• T-Top cross-web
Jacket
• Non-Plenum: Flame-Retardant PVC
• Plenum: Low-Smoke, Flame-Retardant
PVC
PHYSICAL DATA
CMR (Non-Plenum)
Nominal Cable Diameter (in)
Nominal Cable Weight (lbs/1000 ft)
Minimum Bend Radius (in)
Maximum Pulling Force (lbs)
Temperature Rating (˚C)
Installation:
Operation:
0 to +60
-20 to +75
0 to +60
-20 to +75
0.330
42
1.5
40
CMP (Plenum)
0.320
45
1.5
40
PART NUMBERS
Standard packaging: 1000' Spool
Spool
Jacket Color
Blue
White
Yellow
Gray
CMR (Non-Plenum)
7133819
7133820
7133822
7133821
7133824
7133826
7133823
7133828
7133827
7133825
CMP (Plenum)
7131819
7131820
7131822
7131821
7131824
7131826
7131823
7131828
7131827
7131825
TIA 568-C.2
Red
Orange
Green
Black
Pink
Purple
Note: Non-stock items may be subject to minimum order quantities.
Data subject to change without notice.
18
Signal Strength and Power
ELECTRICAL PERFORMANCE
Frequency PSACR*
MHz
(min)
1
4
8
10
16
20
25
31.25
62.5
100
200
250
300
400
500
70.2
59.5
53.5
51.4
46.7
44.4
41.9
39.4
30.4
23.2
10.2
5.2
0.8
—
—
ACR*
(min)
72.2
61.5
55.5
53.4
48.7
46.4
43.9
41.4
32.4
25.2
12.2
7.2
2.8
—
—
Insertion
Loss
(max)
2.1
3.8
5.3
5.9
7.5
8.4
9.4
10.5
15.0
19.1
27.6
31.1
34.3
40.1
45.3
PSNEXT
(min)
72.3
63.3
58.8
57.3
54.2
52.8
51.3
49.9
45.4
42.3
37.8
36.3
35.1
33.3
31.8
NEXT
(min)
74.3
65.3
60.8
59.3
56.2
54.8
53.3
51.9
47.4
44.3
39.8
38.3
37.1
35.3
33.8
PSACRF
(min)
64.8
52.8
46.7
44.8
40.7
38.8
36.8
34.9
28.9
24.8
18.8
16.8
15.3
12.8
10.8
ACRF
(min)
67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
21.8
19.8
18.3
15.8
13.8
Return Loss
(min)
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.0
17.3
16.8
15.9
15.2
TCL PSANEXT PSAACRF
(min)
(min)
(min)
40.0
40.0
40.0
40.0
38.0
37.0
36.0
35.1
32.0
30.0
27.0
26.0
25.2
24.0
23.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
67.0
65.6
62.5
58.0
56.5
55.3
53.5
52.0
67.0
66.2
60.1
58.2
54.1
52.2
50.2
48.3
42.3
38.2
32.2
30.2
28.7
26.2
24.2
Note: Values are expressed in dB per 100 m (328 ft.) length @ 20˚C.
*PSACR & ACR not specified in ANSI/TIA 568-C.2
GenSPEED
®
10,000 CATEGORY 6a CROSS-SECTION
ELECTRICAL CHARACTERISTICS
DC Resistance (max)
Ohms/100 m (328 ft) @ 20˚C
DC Resistance Unbalance (max)
Individual Pair %
8.9
4.0
35
70
Ohms
100 ± 15
AirEs
JACKET
T-TOP
SEPARATOR
INSULATION
23 AWG
CONDUCTOR
Delay Skew (max)
ns/100 m
Nom. Velocity of Propagation
% Speed of Light
Characteristic Impedance
Frequency (f):
1-500 MHz
19