Part Number:
8618
Audio/Control/Instrumentation, (3) 16 AWG (19X29) TC, PE/PVC, Foil Shld
Product Description
Three 16 AWG stranded (19x29) tinned copper conductors, conductors cabled, polyethylene insulation, overall Beldfoil® shield (100% coverage), PVC jacket.
Technical Specifications
Physical Characteristics (Overall)
Conductor
AWG Stranding
16
19x29
Material
No. of Conductors
TC - Tinned Copper 3
3
16 AWG
Conductor Count:
Conductor Size:
Insulation
Material
Nominal Wall Thickness
PE - Polyethylene 0.0315 in
Color Chart
Number Color
1
2
3
Black
Red
Clear
Outer Shield Material
Type
Material
Material Trade Name Coverage [%] Drainwire Material
Beldfoil® (Z-Fold®)
100 %
Drainwire AWG Drainwire Construction n x D
16x30 mm
Tape Aluminum Foil-Polyester
Tape
Outer Jacket Material
Material
TC - Tinned Copper 18
Nominal Diameter Nominal Wall Thickness
0.031 in
PVC - Polyvinyl Chloride 0.327 in
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR
4.8 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
26 pF/ft
Shielding:
Current
Max. Recommended Current [A]
7 Amps per conductor @ 25°C
Voltage
UL Description
UL Voltage Rating
50 pF/ft
Foil(s) or Copper Tape(s)
AWM Style 2107 600V RMS
CL3
300 V RMS
Temperature Range
UL Temp Rating:
Operating Temp Range:
80°C (UL AWM Style 20253)
-20°C To +80°C
Mechanical Characteristics
Bulk Cable Weight:
Max Recommended Pulling Tension:
Min Bend Radius/Minor Axis:
60 lbs/1000ft
110 lbs
3.5 in
Standards
NEC Articles:
NEC/(UL) Specification:
UL AWM Style:
CPR Euroclass:
800
CL3
UL Style 20253 (600 V 80°C)
Eca
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV):
EU Directive 2003/96/EC (BFR):
EU Directive 2011/65/EU (ROHS II):
EU Directive 2012/19/EU (WEEE):
EU Directive 2015/863/EU:
EU Directive Compliance:
EU CE Mark:
EU RoHS Compliance Date (yyyy-mm-dd):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
Yes
Yes
Yes
EU Directive 2003/11/EC (BFR)
Yes
2004-01-01
Yes
Yes
Flammability, LS0H, Toxicity Testing
UL Flammability:
UL Voltage Rating:
UL1685 UL Loading
600 V RMS
Plenum/Non-Plenum
Plenum (Y/N):
No
Part Number
Variants
Item #
Color
Footnote
8618 0601000 CHROME C
8618 060500
CHROME C
8618 0605000 CHROME
8618 060U500 CHROME
Footnote:
C - CRATE REEL PUT-UP.
© 2018 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.