25 WATT
DC-DC
CONVERTER
SVA-SC series
Single Channel
Features
1. Very small (one of the smallest in
Japan)
2. No derating when mounted on a
horizontal surface
3. Low impedance capacitors
4. Over voltage protection
5. EMI: Complies with FCC/A
The SV-series has been developed to follow ETA’s
philosophy of “Miniaturization and high efficiency” of
power supplies. The small size and high efficiency are
suitable for many applications, especially small equipment.
SVA-SC12 Input Specifications
Specifications
Input Characteristic
25WATTS/1 OUTPUT
SVA**SC12
SVA05SC12 SVA12SC12
SVA15SC12 SVA24SC12
Model
SVA48SC12
Input Voltage
Input Range
Inrush Current
Efficiency [%] (typical) *1
78
80
DC12V
DC9.2-16V
Not specified
81
83
83
E T A -U S A
Sub.ETA ELECTRIC IND., CO. LTD.
16170 Vineyard Blvd. #180
Morgan Hill, CA 95037
Phone: (408) 778-2793 Fax: (408) 779-2753
www.eta-usa.com
SVA-SC24 Input Specifications
Specifications
SVA05SC24 SVA12SC24
SVA**SC24
25WATTS/1 OUTPUT
Input Characteristic
Input Voltage
Input Range
Inrush Current
Efficiency [%] (typical) *1
Model
SVA15SC24
SVA24SC24
SVA48SC24
79
81
DC24V
DC19-32V
Not specified
83
85
86
SVA-SC48 Input Specifications
Specifications
SVA**SC48
25WATTS/1 OUTPUT
Model
SVA05SC48
SVA12SC48
SVA15SC48
SVA24SC48
SVA48SC48
Input Characteristic
Input Voltage
Input Range
Inrush Current
Efficiency [%] (typical) *1
DC48V
DC38-63V
Not specified
85
81
84
87
88
ETA-USA
Sub.ETA ELECTRIC IND., CO. LTD.
16170 Vineyard Blvd. #180
Morgan Hill, CA 95037
Phone: (408) 778-2793 Fax: (408) 779-2753
www.eta-usa.com
SVA-SC12 Output Specifications
Specifications
SVA**SC12
(25WATTS/1 OUTPUT)
Output Characteristic
Output Voltage [V]
Output Current [A]
Voltage Adjust Range
Ripple and Noise [mVp-p](maximum) *2
Regulation
Statistic Line Regulation [mV](maximum)
Statistic Load Regulation [mV](maximum)
Temperature Coefficient *4
Drift[mV](maximum) *5
Dynamic Load Regulation [mV](typical) *6
Model
SVA05SC12
5
5.0
150
40
45
40
150
SVA12SC12
12
SVA15SC12
15
SVA24SC12
24
SVA48SC12
48
0.5
580
384
432
255
1440
2.1
1.7
1.1
+/-10% of Rated Output Voltage(at no load within input range)
220
96
108
75
360
250
120
135
0.03%/°C
90
450
2.0mS(typical)
100mS(maximum) at 25°C and rated input/output
Not specified
Current Limiting with automatic recovery
340
192
216
135
720
Recovery Time *5
Rise up time
Hold up time
Functions
Over current Protection
≥110%
of Rated Output
Over voltage Protection
≥110%
of Rated Output
Remote Sense
Remote On/Off
Reverse Voltage Protection
[A]
[V]
5.50
5.50
2.31
13.2
1.87
16.5
not available
not available
by internal fuse
1.21
26.4
0.55
52.8
Output shutdown(to reset, leave 1minute after shutdown)
Environmental
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
0 to +50°C
85%RH(non-condensing)
-20 to +85°C
85%RH(non-condensing)
Primary-Secondary AC2,000Vfor 1minute
Primary-Frame Ground AC2,000V for 1minute
Isolation Resistance
Vibration
Shock
Cooling
□
Line Conduction Noise
□
Safety
Weight (typical)
Dimensions (mm)
□
MTBF [H]
□
Switching Frequency[kHz](typical)
100 Fix.
100 Fix.
Secondary-Frame Ground AC500V for 1minute
Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
2
,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
294m/s
2
Convection
Not specified
-
210g
73W x 95L x 24H
640,000
90 Fix.
90 Fix.
90 Fix.
ETA-USA
Sub.ETA ELECTRIC IND., CO. LTD.
16170 Vineyard Blvd. #180
Morgan Hill, CA 95037
Phone: (408) 778-2793 Fax: (408) 779-2753
www.eta-usa.com
SVA-SC24 Output Specifications
Specifications
Output Characteristic
Output Voltage [V]
Output Current [A]
Voltage Adjust Range
Ripple and Noise [mVp-p](maximum) *2
Model
SVA12SC24
SVA15SC24
SVA24SC24
SVA48SC24
SVA**SC24
(25WATTS/1
OUTPUT)
SVA05SC24
5
5.0
150
40
45
40
150
12
15
24
2.1
1.7
1.1
+/-10% of Rated Output Voltage(at no load within input range)
220
250
340
120
192
135
216
0.03%/°C
75
90
135
360
450
720
0.3mS(typical)
100mS(maximum) at 25°C and rated input/output
Not specified
96
108
48
0.5
580
384
432
255
1440
Regulation
Statistic Line Regulation [mV](maximum)
Statistic Load Regulation [mV](maximum)
Temperature Coefficient *4
Drift[mV](maximum) *5
Dynamic Load Regulation [mV](typical) *6
Recovery Time *5
Rise up time
Hold up time
Functions
Over current Protection
≥110%
of Rated Output [A]
Over voltage Protection
≥110%
of Rated Output [V]
Remote Sense
Remote On/Off
Reverse Voltage Protection
5.50
5.50
Current Limiting with automatic recovery
2.31
1.87
1.21
Output shutdown(to reset, leave 1minute after shutdown)
13.2
16.5
26.4
not available
not available
by internal fuse
0.55
52.8
Environmental
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
0 to +50°C
85%RH(non-condensing)
-20 to +85°C
85%RH(non-condensing)
Primary-Secondary AC2,000Vfor 1minute
Primary-Frame Ground AC2,000V for 1minute
Secondary-Frame Ground AC500V for 1minute
Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
2
,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
Isolation Resistance
Vibration
Shock
Cooling
□
Line Conduction Noise
□
Safety
Weight (typical)
Dimensions (mm)
□
MTBF [H]
□
Switching Frequency[kHz](typical)
90 Fix.
ETA-USA
Sub.ETA ELECTRIC IND., CO. LTD.
16170 Vineyard Blvd. #180
Morgan Hill, CA 95037
Phone: (408) 778-2793 Fax: (408) 779-2753
www.eta-usa.com
90 Fix.
294m/s
2
Convection
Not specified
-
210g
73W x 95L x 24H
740,000
90 Fix.
90 Fix.
90 Fix.
SVA-SC48 Output Specifications
Specifications
SVA**SC48
(25WATTS/1 OUTPUT)
Input Characteristic
Input Voltage
Input Range
Inrush Current
Efficiency [%] (typical) *1
Output Characteristic
Output Voltage [V]
Output Current [A]
Voltage Adjust Range
Ripple and Noise [mVp-p](maximum) *2
Regulation
Statistic Line Regulation [mV](maximum)
Statistic Load Regulation [mV](maximum)
Temperature Coefficient *3
Drift[mV](maximum) *4
Dynamic Load Regulation [mV](typical) *5
Recovery Time *5
Rise up time
Hold up time
Functions
Over current Protection
≥110%
of Rated Output [A]
Over voltage Protection
≥110%
of Rated Output [V]
Remote Sense
Remote On/Off
Reverse Voltage Protection
Environmental
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
SVA05SC48
SVA12SC48
Model
SVA15SC48
DC48V
DC38-63V
Not specified
85
SVA24SC48
SVA48SC48
81
5
5.0
150
40
45
40
150
84
87
88
12
15
24
48
2.1
1.7
1.1
0.5
+/-10% of Rated Output Voltage(at no load within input range)
220
250
340
580
120
192
135
216
0.03%/°C
75
90
135
360
450
720
0.3mS(typical)
500mS(maximum) at 25°C and rated input/output
Not specified
Current Limiting with automatic recovery
2.31
1.87
1.21
Output shutdown(to reset, leave 1minute after shutdown)
13.2
16.5
26.4
not available
not available
by internal fuse
96
108
384
432
255
1440
5.50
5.50
0.55
52.8
Isolation Resistance
Vibration
Shock
Cooling
□
Line Conduction Noise
□
Safety
Weight (typical)
Dimensions (mm)
□
MTBF [H]
□
Switching Frequency[kHz](typical)
0 to +50°C
85%RH(non-condensing)
-20 to +85°C
85%RH(non-condensing)
Primary-Secondary AC2,000Vfor 1minute
Primary-Frame Ground AC2,000V for 1minute
Secondary-Frame Ground AC500V for 1minute
Primary-Secondary-Frame Ground 50MΩ(minimum) by DC500V insulation tester
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s
2
,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
294m/s
2
Convection
Not specified
-
210g
73W x 95L x 24H
90 Fix.
90 Fix.
740,000
90 Fix.
90 Fix.
90 Fix.
ETA-USA
Sub.ETA ELECTRIC IND., CO. LTD.
16170 Vineyard Blvd. #180
Morgan Hill, CA 95037
Phone: (408) 778-2793 Fax: (408) 779-2753
www.eta-usa.com