EMC Filters
Series/Type:
B84299K0061
The following products presented in this data sheet are being withdrawn.
Ordering Code
B84299K00670000
B84299K00660000
Substitute Product
B84113H*,
B84115E*,
B84143B*R*
B84113H*,
B84115E*,
B84143B*R*
Date of
Withdrawal
2012-02-10
Deadline Last
Orders
2012-09-28
Last Shipments
2012-12-31
2012-02-10
2012-09-28
2012-12-31
B84299K00650000
B84299K00660000, 2012-01-13
B84142B0016R000
2012-06-30
2012-09-30
Ordering Code
B84299K0064C000
Substitute Product
B84113H*,
B84115E*,
B84143B*R*
B84113H*,
B84115E*,
B84143B*R*
B84113H*,
B84115E*,
B84143B*R*
B84113H*,
B84115E*,
B84143B*R*
Date of
Withdrawal
2012-02-10
Deadline Last
Orders
2012-09-28
Last Shipments
2012-12-31
B84299K0063C000
B84299K0062C000
2012-02-10
2012-09-28
2012-12-31
2012-02-10
2012-09-28
2012-12-31
B84299K0061C000
2012-02-10
2012-09-28
2012-12-31
For further information please contact your nearest EPCOS sales office, which will also support
you in selecting a suitable substitute. The addresses of our worldwide sales network are
presented at www.epcos.com/sales.
2-line filters
for installations and systems
Technical data and measuring conditions
Rated voltage V
R
Rated current I
R
Test voltage V
test
Overload capability (thermal)
Leakage current l
leak
Climatic category (IEC 60068-1)
250 V DC/AC, 50/60 Hz
B84299K0061 … K0067
Referred to 40
°C
ambient temperature
1414 V DC, 2 s (line/line)
2830 V DC, 2 s (lines/case)
1.5 · I
R
for 3 min per hour or
2.5 · I
R
for 30 s per hour
At 230 V AC, 50 Hz
For K0061 and K0062:
25/100/21 (–25
°C/+100 °C/21
days damp heat test)
For K0063 ... K0067:
25/085/21 (–25
°C/+85 °C/21
days damp heat test)
EN 133200, UL 1283
Approvals
Characteristics and ordering codes
V
R
AC/DC
V
250
I
R
A
2
4
6
10
16
25
36
Terminal
cross section
AWG
mm
2
1.0
1.0
1.0
1.5
2.5
4.0
6.0
18
18
18
16
14
12
10
l
leak
mA
<
3.5
<
3.5
<
3.5
<
3.5
<
3.5
<
3.5
<
10
R
typ
mΩ
530
150
100
45
35
25
10
Approx. Ordering code
weight
kg
0.35
0.37
0.82
1.0
1.8
2.9
2.9
B84299K0061C000
B84299K0062C000
B84299K0063
B84299K0064C000
B84299K0065
B84299K0066
B84299K0067
Approvals
×
×
—
—
—
—
—
—
—
×
×
—
—
—
×
= approval granted
Please read
Cautions and warnings
and
Important notes
at the end of this document.
3
01/06
2-line filters
for installations and systems
Dimensional drawings
B84299K0061C000, B84299K0062C000 (2 and 4 A)
M4 x 6
B84299K0061 … K0067
30±0.4
3 x litz wires AWG 18
(BU, BK, GNYE)
2 x litz wires
AWG 18 (BU, BK)
51
7
300±15
Load
Line
350±15
7
45
Type
Marking
Length
65 mm
75 mm
B84299K0061C000
B84299K0062C000
SSB2097-8-E
B84299K0063 (6 A)
64±0.4
M4 x 6
46±0.4
3 x litz wires AWG 18
(BU, BK, GNYE)
2 x litz wires
AWG 18 (BU, BK)
7
350±15
300±15
7.5
Load
Line
7
Marking
50
25.9
84.5
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Ground terminal M4 x 6
for shielding braid
or fixing stud
for cable clamp
SSB2098-G-E
4
01/06
67
2-line filters
for installations and systems
B84299K0064C000 (10 A)
80±0.4
M4 x 8
B84299K0061 … K0067
47±0.4
28
2 x litz wires
AWG 16 (BU, BK)
7
350±15
8
Load
Line
Marking
ø10
68.5
100.5
1
55
3 x litz wires AWG 16
(BU, BK, GNYE)
300±15
Ground terminal M4 x 8
for shielding braid
or fixing stud
for cable clamp
7
SSB2099-P-E
Please read
Cautions and warnings
and
Important notes
at the end of this document.
5
01/06
67