Logic elements
FILE No. C.PN.HOM.00007.FR
INERIS No. 18408/05
Equipment intended for use in potentially
explosive atmospheres conforming to
Directive 94/9/EC
Functions
Version
OR
AND
YES
NO
81 521 508
-
-
-
On Sub-base page
36-37
81 540 015
-
-
-
Plug-in
Ø4
81 540 017
-
-
-
Plug-in
Ø6
81 522 505
-
-
On Sub-base page
36-37
Classification
II 2 G D c IIB 65°C(T6) X
Symbol
Characteristics
Push-in connection for semi-rigid
tubing (NFE 49100)
Colour
Operating pressure
Orifice diameter
Flow at 6 bars
Pressure indicator
Switching time
Operating temperature
Mechanical life
Weight
Pilot/pressure curves
Male/Female/Female
Female/Female/Female
bar
mm
Nl/min
ms
°C
operations
g
Blue
2•8
2.7
170
-
-5 +50
>
10
7
25
-
-
Ø 4 mm
-
Blue
2•8
2.7
170
-
-
-5 +50
>
10
7
12
-
Ø 6 mm
Blue
2•8
4
200
-
-
-5 +50
>
10
7
25
-
-
Green
2•8
2.7
170
-
-5 +50
>
10
7
25
P.p : Pilot pressure
P.a : Supply pressure
Principle of operation
Cellule OR
The output signal "S" is present when a signal at
"a" OR "b" is present:
S = a OR b
S=a+b
Cellule AND
The output signal "S" is present only when signals
"a" AND "b" are present simultaneously:
S = a AND b
S=a.b
Dimensions
81 521 508 - 81 522 505
81 540 017 - 81 541 017
81 540 015 - 81 541 015
Other information
See page 36-37 for mounting plan for logic elements.
To order an
product, you must complete the form on page 53.
28
-
81 541 0015
-
-
Plug-in
Ø4
-
81 541 017
-
-
Plug-in
Ø6
-
-
81 501 031
-
On sub-base
page 36-37
-
-
81 503 028
-
Threshold
On sub-base page
36-37
-
-
-
81 504 035
Threshold
On sub-base page
36-37
-
-
-
81 506 027
Threshold
On sub-base page
36-37
II 2 G D c IIB 65°C(T6) X
Ø 4 mm
-
Green
2•8
2.7
150
-
-
-5 +50
>
10
7
13
-
Ø 6 mm
Green
2•8
4
200
-
-5 +50
>
10
7
25
-
-
Yellow
2•8
2.7
170
<4
-5 +50
>
10
7
30
P.p (bars)
-
-
Orange
2•8
2.7
170
<4
-5 +50
>
10
7
30
P.p (bars)
-
-
Light grey
2•8
2.7
170
<4
-5 +50
>
10
7
30
P.p (bars)
-
-
Dark grey
2•8
2.7
170
<4
-5 +50
>
10
7
30
P.p (bars)
P.a (bars)
P.a (bars)
P.a (bars)
P.a (bars)
YES element
The output signal "S" is only present when the
pilot is present "a" is present:
S = a YES b
S=a
NOT element
The output signal "s" is present only if the input signal
"a" is NOT present. The output signal is therefore the
inverse of the pilot signal:
S= NOT a
S=a
If the supply port is connected to a 2nd input "b", the
function obtained is called inhibition:
S = NOT a AND b
S=a.b
81 501 031 - 81 503 028
81 504 035 - 81 506 027
To order an
product, you must complete the form on page 53.
29