KEH SERIES
Three Phase Superior Performance EMI Filter – Dual Stage DELTA Configuration
DATASHEET
High attenuation and superior performance when used in applications with low Impedance load
controlling pulsed, continuous and intermittent interference noise and where high levels of mains
borne interference are present.
Approvals & Compliance
UL Recognised *
CSA Certified **
*31
st
July 2020
**31
st
August 2020
Features
Typical Circuit Diagram
•
•
•
•
•
Dual Stage Filter
Good Attenuation
Chassis mounting
Low Leakage current
Superior Performance
Applications
Specifications
Electrical Characteristics
Maximum Continuous Operating Voltage
Current Ratings
Operating Frequency
High Potential Test Voltage -440VAC
High Potential Test Voltage -520VAC
Overload Capability
Functional Characteristics
Operating Temperature Range
Climatic Category
Termination ( Depends on Current Rating )
Flammability corresponding to
Reference Standards
Design Corresponding to
•
•
•
•
Computer Server
Robotics and Automation
Elevators
SMPS
440/520VAC
10A to 250A @40°C
50/60Hz
Line to Ground 2632VDC for 1 Minute
Line to Line 1892VDC for 1 Minute
Line to Ground 2856VDC for 1 Minute
Line to Line 2236VDC for 1 Minute
135% of Rated current for 15 minutes
-25°C to +85ºC
25/85/21
Shock Proof (6-100A), Nut & Bolt (150-250A)
UL 94 V-0
UL 60939-3 and CSA 22.2 No.8-13
2376467-1
Rev A
Date: 1-Jul-2020
Dimensions in
millimetres
Dimensions Shown for
reference purposes only.
Specifications subject to
change
For Email, phone or live chat,
go to: www.te.com/help
KEH SERIES
Insertion Loss (Typical) – Measured in Closed 50Ω System
Common Mode 50Ω / 50Ω
Frequency in MHz
0.15
0.5
1
3
75
86
81
63
75
80
81
64
55
72
67
58
72
75
77
66
41
78
72
70
37
75
65
57
35
77
68
57
54
58
53
44
52
56
54
42
50
55
51
42
10A
15A
20A
40A
60A
80A
100A
150A
200A
250A
0.01
70
65
41
11
27
10
3
18
19
18
0.05
71
65
44
20
26
8
8
24
22
24
5
54
55
51
62
65
50
51
40
40
38
10
40
40
38
51
43
44
42
35
35
33
30
38
36
21
32
24
28
28
32
32
32
Current Rating
10A
15A
20A
40A
60A
80A
100A
150A
200A
250A
0.01
51
50
48
29
17
28
28
38
38
38
0.05
53
51
46
36
20
29
29
41
41
41
Differential Mode 50Ω / 50Ω
Frequency in MHz
0.15
0.5
1
3
64
82
84
63
65
82
85
68
60
79
79
59
76
78
79
64
24
50
61
60
32
72
66
46
32
75
66
46
55
51
47
40
55
50
45
40
55
52
45
39
5
48
50
45
48
50
36
37
37
35
35
10
19
20
20
23
46
27
27
30
30
29
30
22
23
26
26
72
22
25
25
22
27
Common Mode Insertion Loss (Typical in dB – refer to Table above)
10A
15A
Current Rating
2376467-1
Rev A
Date: 1-Jul-2020
Dimensions in
millimetres
Dimensions Shown for
reference purposes only.
Specifications subject to
change
For Email, phone or live chat,
go to: www.te.com/help
KEH SERIES
Case Dimensions
10A to 60A Shock Proof Types
80A to 100A Shock Proof Types
150A Nut & Bolt Type
200A to 250A Nut & Bolt Types
All dimensions in mm; Tolerances according: ISO2768-m
2376467-1
Rev A
Date: 1-Jul-2020
Dimensions in
millimetres
Dimensions Shown for
reference purposes only.
Specifications subject to
change
For Email, phone or live chat,
go to: www.te.com/help