Multifunction Timer
Analog Set Multifunction Timers
In Slim 22.5 mm Design
For Track Mounting
H
Wide AC/DC power supply range
(24 to 230 VAC/DC) minimizes inventory
H3DE
H
12 VDC available in H3DE-M model
H
Programmable contacts (available in
-M2 and -S2 models) can enable and
disable a self-holding relay circuit
H
Eight operating modes in the H3DE-M
(four in the H3DE-S) offer wide
application flexibility
H
Time setting range 0.10 sec to 120 hrs
H
Finger protection terminal block
Ordering Information
J
TIMER
Description
Contact output
DPDT (time-limit output SPDT);
and switchable SPDT
(time-limit
←→
instantaneous)
Supply voltage
12 VDC
24 to 230
VAC/DC
Part number
Multifunctional
H3DE-M2 DC12
H3DE-M2 AC/DC24-230
H3DE-M1 AC/DC24-230
Standard
—
H3DE-S2 AC/DC24-230
H3DE-S1 AC/DC24-230
SPDT (time-limit output SPDT)
J
MODEL NUMBER LEGEND
H3DE-j-j-j
1
2 3
1. M: Multifunction type
S: Standard type
2. 1: SPDT
2: DPDT
3. Supply voltage
J
ACCESSORIES (ORDER SEPARATELY)
Item
Mounting track
Description
50 cm (l) x 7.3 mm (t)
1 m (l) x 7.3 mm (t)
1 m (l) x 16 mm (t)
End plate
Spacer
Part number
PFP-50N
PFP-100N
PFP-100N2
PFP-M
PFP-S
1
H3DE
H3DE
Specifications
J
GENERAL
Item
Operating mode
H3DE-M2
H3DE-M1
H3DE-S2
H3DE-S1
A: ON-delay (Signal or Power)
B: Repeat-cycle OFF start (Signal or Power)
B2: Repeat-cycle ON start (Signal or Power)
C: Signal ON-/OFF-delay
D: Signal OFF-delay
E: Interval (Signal or Power)
G: Signal ON-/OFF-delay
J: One-shot (Signal or Power)
0.98 N
S
m max. {approx. 10 kgf
S
cm max.}
Voltage input
Relay: DPDT
Nameplate
UL508, CSA 22.2 No.14
Conforms to EN61812-1, IEC60664-1 (VDE0110) 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)
Relay: SPDT
DIN track mounting (See Note.)
---
Relay: DPDT
Relay: SPDT
A: ON-delay
B2: Repeat-cycle ON start
E: Interval
J: One-shot
Terminal block
Terminal screw tightening
torque
Input type
Output type
Mounting method
Attachment
Approved standards
Clamps two 2.5 mm
2
max. bar terminals without sleeves.
Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.
J
TIME RANGES
Time scale display
x 0.1
x1
Time unit display
seconds
0.1 to 1.2 s
1 to 12 s
min
0.1 to 1.2 min
1 to 12 min
hrs
0.1 to 1.2 h
1 to 12 h
10 h
1 to 12 h
10 to 120 h
Note: When the main dial is set to “0” for all settings, the output will operate instantaneously.
J
RATINGS
Rated supply voltage
(See Notes 1 and 2.)
Operating voltage range
Power reset
Reset voltage
Power
consumption
p
(See N t 3 )
(S Note 3.)
H3DE-M1
H3DE-M2
H3DE-S1
H3DE-S2
Voltage input
24 to 230 VAC/DC (50/60 Hz)
12 VDC (H3DE-M2 model only)
85% to 110% of rated supply voltage
Minimum power-off time: 0.1 s
2.4 VAC/DC max.
AC: approx. 4.3 VA (2.2 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 4.8 VA (2.4 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
AC: approx. 2.7 VA (1.6 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 3.2 VA (1.9 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
Max. permissible capacitance between input lines (terminals B1 and A2) : 2000 pF
Load connectable in parallel with inputs (terminals B1 and A2)
H-level: 20.4 to 253 VAC/DC
L-level: 0 to 2.4 VAC/DC
Contact output: 5 A at 250 VAC with resistive load (cosφ = 1); 5 A at 30 VDC with resistive
load (cosφ = 1)
Operating: -
-10°C to 55°C (14 to 131°F) with no icing
Storage: -
-25°C to 65°C (-
-13°F to 149°F) with no icing
Operating: 35% to 85%
Control output
Ambient temperature
Ambient humidity
Note: 1. DC ripple rate: 20% max.
2. Since an inrush current of 0.25 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning
on or off the power supply to the Timer with a solid-state output such as a sensor.
3. The power consumption is for mode A (ON-delay) after the Timer counts the time-up time and for the AC input at 50 Hz. The
power consumption of the H3DE-Mj includes the input circuit with the B1 and A1 terminals short-circuited.
2
H3DE
J
CHARACTERISTICS
Accuracy of operating time
Setting error
Signal input time
Voltage influence
Temperature influence
Insulation resistance
Dielectric strength
±1%
max. of FS (±1%
±10
ms max. at 1.2-s range) (See Note 1.)
±10% ±50
ms max. of FS (See Note 1.)
50 ms min. (See Note 1.)
±0.5%
max. of FS (±0.5%
±10
ms max. at 1.2-s range)
±2%
max. of FS (±2%
±10
ms max. at 1.2-s range)
100 MΩ min. at 500 VDC
H3DE
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min.
Between control output terminals and operating circuit: 2,000 VAC for 1 min.
Between contacts of different polarities: 2,000 VAC for 1 min.
Between contacts not located next to each other: 1,000 VAC for 1 min.
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Malfunction: 100 m/s
2
(approximately 10G)
Destruction: 1,000 m/s
2
(approximately 100G)
AgNi+gold plating (Use the G6RN-1 at 12 VDC.)
3 kV (between power terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Square-wave noise generated by noise simulator (pulse width: 100 ns/1
µs,
1-ns rise)
±1.5
kV
Malfunction: 4 kV
Destruction: 8 kV
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
(See Note 2.)
EMI
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
Harmonic Current: EN61000-3-2
Voltage Fluctuation and Flickering EN61000-3-3
EMS
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3);
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3);
1 kV control port with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3);
1 kV differential mode (level 3)
Vibration resistance
Shock resistance
Contact material
Impulse withstand voltage
Noise immunity
Static immunity
Life expectancy
EMC
Enclosure rating
Weight
IP30 (Terminal block: IP20)
120 g
Note: 1. With the H3DE-Mj, if the voltage exceeds 26.4 VAC/DC, the following hold at signal OFF for C, D, and G modes:
Accuracy of operating time:
±1% ±50
ms max. at 1.2-s range
Setting error:
±10%
+100/-
-50 ms max.
Signal input time: 100 ms min.
2. For reference : A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
3
H3DE
H3DE
Nomenclature
J
H3DE-F
Front View
Time scale indicator
Time scale selector
(select 0.1 or 1)
Output indicator (orange)
(Lit while Timer gives output.)
Operating mode selector
(select a mode from A, B, C,
B2, D, E, J, and G for the
H3DE-M1/-M2, from A, E, J,
and B2 for the H3DE-S1/S2)
Power-on indicator (green)
(Lit while the power is on.)
Nameplate (20 x 5.4 mm white panel)
Time unit display window
Time unit selector (select one from
sec, min, hrs, and 10 h)
Main dial (for setting a time value)
Operating mode display window
Bottom View
Output Type Selector Switch Settings
Setting
Output type
Time-limit output (terminal numbers 25, 26 and
28) (default setting)
Output type selector switch for
H3DE-M2/-S2 (default setting
is time-limit output)
Instantaneous output
(terminal numbers 21, 22 and 24)
4
H3DE
H3DE
Operation
J
BLOCK DIAGRAM
H3DE-M1/-M2
Zero setting
detection
circuit
AC (DC) input
Time range/
unit selectors
Operating
mode selector
Power supply
circuit
Oscillation
circuit
Counting
circuit
Output circuit
Start input
Input circuit
Indicator
circuit
Power-ON Output
indicator
indicator
H3DE-S1/-S2
Zero setting
detection
circuit
AC (DC) input
Time range/
unit selectors
Operating
mode selector
Power supply
circuit
Oscillation
circuit
Counting
circuit
Output circuit
Indicator
circuit
Power-ON Output
indicator
indicator
J
I/O FUNCTIONS
Item
Input
Output
Start
Control output
H3DE-M1/-M2
Starts operation.
H3DE-S1/-S2
No input is available.
Outputs are turned ON according to designated output mode when preset value is reached. (See Note.)
Note: When the output type selector switch on the bottom of the Timer is set to the instantaneous side, the relay R2 (terminal numbers
21/25, 22/26, and 24/28) becomes an instantaneous contact and turns ON/OFF in synchronization with the changes in the power
supply.
5