Reflective Mapping Sensor
E3C-L11M
CSM_E3C-L11M_DS_E_2_1
Ideal for Mapping Liquid Crystal
Glass Plates on Cassette Trays
Be sure to read
Safety Precautions
on page 3.
Features
Detects glass plates without being
influenced by the processing condition of its
edges.
Stably detects on-tray glass plates even if
the glass plates are offset.
±10
mm
Rounded
edge
Warp
Chamfered
edge
±10°
The stable detection of glass plates is possible without being
influenced by the processing condition of its glass edges (e.g.,
rounded or chamfered edges) or warps due to the weight of
the glass plates.
Note: Be sure to confirm operation before use.
The E3C-L11M ensures stable detection in a sensing range of
±10
mm or
±10°
from the center distance of glass substrates
set in cassettes or trays.
1
E3C-L11M
Ordering Information
Sensor
Sensing method
Reflective
Appearance
Sensing distance
Infrared light
Model
E3C-L11M
20±10 mm
Amplifier
Appearance
Power supply
12 to 24 VDC
Functions
Model
E3C-JC4P
Self-diagnosis
Ratings and Specifications
Sensor
Sensing method
Item
Sensing distance
Standard sensing object
Differential travel
*1
Light source (wavelength)
Angle of sensing object
*2
Ambient illumination (receiver
side)
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance (destruction)
Shock resistance (destruction)
Degree of protection
Connection method
Weight (packed state)
Material
Accessories
Standard
sensing object
Sensor
Reflective
E3C-L11M
20±10 mm
Cut edge of transparent glass (t = 0.7 mm)
0.5 mm max. (at a sensing distance of 20 mm)
Infrared LED (860 nm)
±10° max. (at a sensing distance of 20 mm)
Incandescent lamp: 1,500 lx
Operating: 0 to 40°C, Storage:
−40
to 70°C (with no icing or condensation)
Operating/Storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC (50/60 Hz) for 1 min
10 to 150 Hz, 0.75-mm double amplitude or 100 m/s
2
for 2 hrs each in X, Y, and Z directions
300 m/s
2
for 3 times each in X, Y, and Z directions
IEC IP50
Pre-wired cable (standard length: 2 m)
Approx. 50 g
Model
Distance between sensing objects
10 mm max. (at a sensing distance of 20 mm)
Case
Lens
ABS
PVC
Phillips screw M4
×
18, Spring washers, Flat washers, Instruction sheet
*1. The differential travel is the hysteresis of the Sensor with the standard sensing object moving perpendicular to the Sensor.
Vertical direction
*2.
Standard
sensing object
Sensor
Indication
Amplifier Unit
For details, refer to E3C Series.
2
E3C-L11M
Engineering Data (Typical)
Operating Range
Distance Y (mm)
6
Sensing object: 0.7-mm-thick transparent
glass with 4% reflection ratio
Size: 360
×
460 mm
Sensing Angle
Operating angle (θ)
30
Sensing object: 0.7-mm-thick transparent
glass with 4% reflection ratio
Size: 360
×
460 mm
Sensing object
Sensor
4
20
2
Y
Sensing object
X
Sensor
10
X
θ
0
10
20
30
0
10
20
30
Distance X (mm)
−2
−10
Distance X (mm)
−4
−6
−20
−30
I/O Circuit Diagrams
NPN Output
Model
Operation
mode
Timing charts
Incident light
No incident light
Light indicator ON
(orange)
OFF
ON
Output
OFF
transistor
Load (e.g., relay) ON
OFF
Incident light
No incident light
Light indicator ON
(orange)
OFF
ON
Output
OFF
transistor
Load (e.g., relay) ON
OFF
Output circuit
Light-ON
12 to
Brown 24 VDC
40 ms
Light
indicator
(red)
Stability
indicator
(green)
Photo-
electric
Sensor
main
circuit
E3C-L11M +
E3C-JC4P
Z
0
Black
Output
Blue
100 mA
Load max.
0V
Z
1
Pink
Self-diagnostic
output (50 mA max.)
Dark-ON
40 ms
Connection
E3C-L11M
Sensor
Shield
White
Shield
Red
1
2
3
4
E3C-JC4P
Amplifier
Brown
Black
Blue
Pink
12 to 24 VDC
Control output
0V
Self-diagnostic output
Safety Precautions
WARNING
This product is not designed or rated for
ensuring safety of persons. Do not use it for
such purpose.
Precautions for Correct Use
Do not use the product in atmospheres or environments that
exceed product ratings.
●
Mounting
The torque required to tighten each screw must be 0.71 N·m
maximum. Excessive tightening torque may damage the
Sensor and Amplifier.
●
Wiring
A maximum of 24 VDC±10% can be imposed on the E3C-
L11M. Check that the voltage of the power supply is within the
permissible range before turning on the E3C-L11M.
3
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
•
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
•
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
•
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.9
In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/
OMRON Corporation
(c)Copyright OMRON Corporation 2008 All Right Reserved.