Type 2 surge protection device - VAL-MS 230/FM - 2839130
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in
the user's documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
Surge voltage arrester consisting of base element with remote indicator contact and ground
connector with high-capacity varistor, for mounting on NS 35/7.5, nominal voltage: 230 V AC, 1-
channel
Why buy this product
Single-channel, DIN-rail mountable protective devices
Base element with/without floating remote indication contact
Mechanical keying of all slots
Optical, mechanical status indication for the individual arresters
Consists of base element and plug
Disconnect device on each individual plug
Key commercial data
Packing unit
Minimum order quantity
Catalog page
GTIN
Custom tariff number
Country of origin
85363030
GERMANY
1
1
Page 38 (TT-2011)
Technical data
Standards
Housing material
Inflammability class according to UL 94
Color
Standards for air and creepage distances
Standards for air and creepage distances
Degree of protection
Mounting type
Design
Number of positions
Ambient temperature (operation)
PA
V0
black
DIN VDE 0110-1
IEC 664-1
IP20
DIN rail: 35 mm
DIN rail module, two-section, divisible
1
-40 °C ... 80 °C
04.10.2012 Page 1 / 12
https://www.phoenixcontact.com/us/produkte/2839130
Type 2 surge protection device - VAL-MS 230/FM - 2839130
Technical data
Standards
Message: Surge protection fault
Direction of action
Width
Height
Depth
Pitch unit
Optical, remote indicator contact
1L-N/PE
17.7 mm
96.8 mm
65.5 mm
1 Div.
Protective circuit
IEC category
IEC category
EN type
Nominal voltage UN
Arrester rated voltage UC
Arrester rated voltage UC (L-N)
Arrester rated voltage UC (L-PEN)
Nominal frequency fN
Ground conductor current IPE
Operating effective current IC at UN
Max. discharge surge current Imax (8/20) µs
Max. discharge surge current Imax (8/20) µs maximum (L-N)
Max. discharge surge current Imax (8/20) µs maximum (L-PEN)
Nominal discharge surge current In (8/20) µs
Nominal discharge surge current In (8/20) µs (L-N)
Nominal discharge surge current In (8/20) µs (L-PEN)
Lightning test current (10/350) µs, peak value limp
Max. energy absorption (2 ms)
Protection level Up
Protection level UP (L-N)
Protection level UP (L-PEN)
Residual voltage
Residual voltage (L-N)
Residual voltage (L-PEN)
Response time
Response time (L-N)
Response time (L-N)
Max. required backup fuse with branch wiring
Short-circuit resistance IP with max. backup fuse (effective)
II
T2
T2
230 V AC
275 V AC
275 V AC
275 V AC
50 Hz (60 Hz)
≤ 300 µA (at UN)
≤ 300 µA
40 kA
40 kA
40 kA
20 kA
20 kA
20 kA
3 kA
550 J
≤ 1.35 kV
≤ 1.35 kV
≤ 1.35 kV
≤ 1 kV (at 5 kA)
≤ 1 kV (at 5 kA)
≤ 1 kV (at 5 kA)
≤ 25 ns
≤ 25 ns
≤ 25 ns
125 A (gL)
25 kA
Connection, protective circuit
Connection method
Connection type IN
Connection type OUT
Screw thread
Tightening torque
Screw connection
Biconnect screw terminal block
Biconnect screw terminal block
M5
4.5 Nm
04.10.2012 Page 2 / 12
https://www.phoenixcontact.com/us/produkte/2839130
Type 2 surge protection device - VAL-MS 230/FM - 2839130
Technical data
Connection, protective circuit
Tightening torque
Stripping length
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
AWG conductor cross section
30 lb in (UL)
14.5 mm
0.5 mm²
25 mm²
0.5 mm²
35 mm²
20
2
10 ... 2 (UL)
Remote indicator contact
Connection name
Switching function
Connection method
Screw thread
Tightening torque
Tightening torque
Stripping length
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
AWG conductor cross section
Maximum operating voltage Umax. AC
Maximum operating voltage Umax DC
Max. operating current Imax
Max. operating current Imax
Max. operating current Imax
Max. operating current Imax
Min. permissible switching capacity
Remote fault indicator contact
PDT contact
Screw connection
M2
0.25 Nm
4 lb in (UL)
7 mm
0.14 mm²
1.5 mm²
0.14 mm²
1.5 mm²
28
16
30 ... 14 (UL)
250 V AC
125 V DC
1 A AC (inductive)
1 A AC (ohmic)
30 mA DC (inductive)
200 mA DC (ohmic)
0.12 VA (12 V, 10 mA)
Standards
Standards/regulations
Standards/regulations
Standards/regulations
Standards/regulations
IEC 61643-1 2005
EN 61643-11/A11 2007
NF C61-740 1995
UL 1449
Classifications
eclass
eCl@ss 4.0
eCl@ss 4.1
27140201
27130801
04.10.2012 Page 3 / 12
https://www.phoenixcontact.com/us/produkte/2839130
Type 2 surge protection device - VAL-MS 230/FM - 2839130
Classifications
eclass
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
27130801
27130801
27130805
27130805
etim
ETIM 2.0
ETIM 3.0
ETIM 4.0
EC000941
EC000941
EC000941
unspsc
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
30212010
39121610
39121610
39121610
39121620
Approvals
Approvals
Approvals
IECEE CB Scheme / UL Recognized / KEMA-KEUR / ÖVE / cUL Recognized / GOST / GL / CCA / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
IECEE CB Scheme
UL Recognized
KEMA-KEUR
04.10.2012 Page 4 / 12
https://www.phoenixcontact.com/us/produkte/2839130
Type 2 surge protection device - VAL-MS 230/FM - 2839130
Approvals
ÖVE
cUL Recognized
GOST
GL
CCA
cULus Recognized
Accessories
Accessories
Bridges
Wiring bridge - MPB 18/1- 2 - 2809209
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 2-pos.
Wiring bridge - MPB 18/1- 3 - 2809212
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 3-pos.