Fiber
Optics
Duplex flat cable
Application
▪
▪
▪
Patchcord cable
Indoor/point-to-point
Internal wiring
General
This specification covers a figure 8 construction with 2 tight buffer single fiber
units.
Shipping information
Recommended Spool Length 2000 m. Other lengths available upon request.
Construction Data
Tight buffer fiber Diameter
Core reinforce
Subunit color code
Outer jacket material
500 ± 50 µm
Aramid yarn
1. Blue
PVC
2. Orange
1
Laser Components GmbH
Germany
Werner-von-Siemens-Str. 15
82140 Olching
Tel: +49 8142 2864 – 0
Fax: +49 8142 2864 – 11
info@lasercomponents.com
www.lasercomponents.com
Fiber
Optics
Duplex flat cable
Technical Data Physical
Cable diameter (mm)
Cable weight (kg/km)
Subunit diameter (mm)
Temperature rating
Operation
Storage
5.4 x 3.2
16.5
2.2
-20°C ~ +60°C
-20°C ~ +60°C
Technical Data Mechanical
Max. loading (IEC794-1)
Installation
Operation
Min bend radius (IEC794-1)
With load (mm)
Without load (mm)
Crush resistance (IEC794-1)
200N
100N
20xH (Cable axis)
10xH (Cable axis)
500N/100 mm
Technical Data-Transmission
Fiber type
Attenuation (@850 nm)
Bandwidth (@850 nm)
12/12 / V3/ HW / divers-lwl/optische-kabel/si200_duplex-flat_indoor_2_2mm.indd
200/230/500
<8
dB/km
>20
MHz/km
200 ± 4
230 ± 10
500 ± 50
<12
0.37
Core diameter (µm)
Cladding diameter (µm)
Buffer coating diameter (µm)
Cladding/Coating Offset (µm)
Numerical Aperture
LC Part Number: 3003785
2
Laser Components GmbH
Germany
Werner-von-Siemens-Str. 15
82140 Olching
Tel: +49 8142 2864 – 0
Fax: +49 8142 2864 – 11
info@lasercomponents.com
www.lasercomponents.com