CM109
CM110
CL200
Capacitance and
Capacitance/Inductance Meter
CM110
Capacitance Meter
Zero adjust for compensating stray
capacitance
Large easy to read 3-1/2 digits,
2000 count LCD
0.5% measurement accuracy
Fused input
9 measurement ranges
Three measurement frequencies
Includes holster
CL200
3-1/2 Digit 2000
Count L/C Meter
Six capacitance ranges and four
inductance ranges
High accuracy measurement
Automatic zeroing
Low battery indicator
Fuse protected input
Includes holster
CM109
Capacitance Meter
Measures capacitance to 20mF
Zero adjust
Fused input
Large LCD display
Rugged case design
Inputs for clip leads and lead
insertion
CM109
CM110
CL200
SPECIFICATIONS
[ CM109 ]
Capacitance
Range:
200pF, 2nF, 20nF, 200nF 2µF, 20µF, 200µF, 2000µF,
20mF
Best Resolution:
0.1pF
Accuracy:
±0.5% Rdg + 1D: 200pF to 200µF Ranges
±1% Rdg + 1D: 2000µF Range
±2% Rdg + 1D: 20mF Range
Test Frequencies:
200pF to 2µF Ranges: 200Hz
20µF Range: 80Hz
200µF to 20mF Ranges: 8Hz
Zero Adjustment Range:
± 20pF
Overload Protection:
0.25A/250V fuse
General Specifications
Power:
9V battery
Operating Temperature:
0 to 40°C
with a relative humidity of less than 70%
Size:
5.3” H × 2.8” W × 1.3” D
Weight:
7.5 oz.
Supplied Accessories:
Manual, Test leads, Battery, Spare
fuses
[ CM110 ]
Measurement Condition:
Specifications are measured within a
Measurement Condition:
Specifications are measured within a
temperature range of 18°C to 28°C (64°F to 82°F)
temperature Range of 18 to 28°C (64 to 82°F)
Capacitance
Ranges:
200pF, 2nF, 20nF, 200nF, 2µF, 20µF, 200µF,
2000µF, 20000µF
Best Resolution:
0.1pF
Accuracy:
±0.5% + 1D: 200pF to 200µ ranges
±1% + 1D: 2000F range
±2% + 1D: 20mF range
Test Frequencies:
200pF to 2µF ranges: 800Hz
20µF range: 80Hz
200µF to 20,000µF ranges: 8Hz
Zero Adjustment Range:
±20pF
Overload Protection:
0.25A/250V fuse
General Specifications
Power:
9V Battery
Calibration Interval:
1 year
Operating Temperature:
0 to 40°C with a relative humidity of
less than 70%
Size:
5.3” H x 2.8” W x 1.3” D
Weight:
7.5 oz
Supplied Accessories:
Manual, Test leads, Holster, Battery
Capacitance
Ranges:
2nF, 20nF, 200nF, 2µF, 20µF, 200µF
Best Resolution:
1pF
Accuracy:
±1% + 1D: 2nF to 200nF ranges
±2% + 1D: 2µ to 200µF ranges
Test Frequencies:
2nF to 2µF ranges: 900Hz
20 µF and 200µF ranges: 80Hz
Inductance
Ranges:
2mH, 20mH, 200mH, 2H
Best Resolution:
1µH
Accuracy:
± 2% +1D, 2mH to 200mH range
± 5% +1D, 2H range
Test Frequency:
900Hz
General Specifications
Power:
9V NEDA Battery
Calibration Interval:
1 year
Operating Temperature:
0 to 40°C with a relative humidity of
less than 70%
Size:
7.4” H x 3.7” W x 1.3” D
Supplied Accessories:
Manual, Test leads, Holster, Battery
[ CL200 ]
32
Protek Test & Measurement
40 Boroline Road, Allendale, NJ 07401 Tel: 201-760-9898 Fax: 201-760-9888