Fixed Inductors
固定インダクタ
C2LB
Inductance Range:
1.0~1800µH
DIMENSIONS/外½寸法図
FEATURES/特 長
•
Ideal as a choke coil for noise filtering
and DC-DC Convertor application.
•
RoHS compliant.
•
ノイズフィルタやDC-DCコンバータに
φ0.5
(Unit: mm)
φ6.5
Max.
5.1 Max.
4.0
10°
4.0
最適です
•
RoHS指令対応
SELECTION GUIDE FOR STANDARD COILS
TYPE C2LB
東光品番
インダクタンス
(1)
許容差
直流抵抗
(3)
最大許容電流
(2)
TOKO
Part
Number
#C2LB-1R0M
#C2LB-1R2M
#C2LB-1R8M
#C2LB-2R2M
#C2LB-2R7M
#C2LB-3R3M
#C2LB-3R9M
#C2LB-4R7M
#C2LB-5R6M
#C2LB-6R8M
#C2LB-8R2M
#C2LB-100K
#C2LB-120K
#C2LB-150K
#C2LB-180K
#C2LB-220K
#C2LB-270K
#C2LB-330K
#C2LB-390K
#C2LB-470K
#C2LB-560K
#C2LB-680K
#C2LB-820K
#C2LB-101K
#C2LB-121K
#C2LB-151K
#C2LB-181K
#C2LB-221K
#C2LB-271K
#C2LB-331K
#C2LB-391K
#C2LB-471K
#C2LB-561K
#C2LB-681K
#C2LB-821K
#C2LB-102K
#C2LB-122K
#C2LB-152K
#C2LB-182K
Inductance
(1)
(µH)
1.0
1.2
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
82.0
100.0
120.0
150.0
180.0
220.0
270.0
330.0
390.0
470.0
560.0
680.0
820.0
1000.0
1200.0
1500.0
1800.0
Tolerance
(%)
±20
±20
±20
±20
±20
±20
±20
±20
±20
±20
±20
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
DC
Resistance
(3)
(mΩ) Max.
15.6
18.2
26.0
31.2
39.0
45.5
49.5
52.0
71.5
84.5
90.0
105
130
140
180
200
250
350
440
500
580
690
880
1100
1250
1.56Ω
1.92Ω
2.20Ω
2.90Ω
3.60Ω
4.40Ω
5.40Ω
6.00Ω
8.40Ω
9.60Ω
13.5Ω
14.5Ω
21.5Ω
24.0Ω
Rated DC
Current
(2)
(A) Max.
4.0
3.7
3.3
2.9
2.4
2.3
2.2
2.1
1.8
1.7
1.6
1.5
1.4
1.3
1.1
1.0
0.90
0.80
0.74
0.68
0.63
0.50
0.46
0.44
0.38
0.36
0.30
0.28
0.24
0.21
0.19
0.18
0.17
0.14
0.13
0.12
0.11
0.10
0.08
(1) Inductance is measured with a LCR meter 4284A (Agilent Technologies)
or equivalent. Test frequency at 100kHz (1.0 to 8.2µH), at 1.0kHz (10 to 1800µH).
(2) Maximum allowable DC current is that which causes a 10% inductance
reduction from the initial value, or coil temperature to rise by 40°C,
whichever is smaller. (Reference ambient temperature 25°C)
(3) DC resistance is measured with a digital multimeter TR6871 (Advantest)
or equivalent.
(1) インダクタンスはLCRメータ4284A(Agilent Technologies)または同等品により測定
する。
測定周波数は1.0∼8.2μH(100kHz)
、10∼1800μH(1.0kHz)です。
(2) 最大許容電流は、直流重畳電流を流した時インダクタンスの値が初期値より10%減
少する直流電流値、または直流電流により、コイルの温度が40℃上昇の½れか小さ
い値です。(周囲温度25℃を基準とする。)
(3) 直流抵抗はデジタルマルチメータTR6871(Advantest)または同等品により測定する。