20-002-182BPTLHT

产品描述Interconnection Device
产品类别连接器    连接器   
文件大小227KB,共3页
制造商Aries Electronics
下载文档 详细参数 全文预览

20-002-182BPTLHT概述

Interconnection Device

20-002-182BPTLHT规格参数

参数名称属性值
Reach Compliance Codecompli
连接器类型INTERCONNECTION DEVICE
Base Number Matches1

文档预览

下载PDF文档
Series 181 Thru 183
90° Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors
embedded between layers of tough, flexible, flame-retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See Data Sheet
11005
for Flat Pin Staked Flex Jumpers
• For RoHS applications for Lead-Free Soldering use HT Cable
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant Polyester
(Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide (Kapton) insulation
with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equivalent to that
of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min. Nickel per
ASTM-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over 50μ”
[1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps
• Cable voltage rating=300 Volts
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp)
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp)
•Conductor/Contact Resistance (avg.) = 20mOhms initial (max. 20mOhm increase)
based on a 2”cable @20°C.
•Operating temperature=67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square,
.150 [3.81] long minimum.
MOUNTING CONSIDERATIONS:
• Suggested PCB hole size=.032+ .002 .81 + .05] dia.
No. of Conductors:
(4 – 40)
Note: Aries specializes in custom design and production. In addition to
the standard products shown on this page, special materials, platings,
sizes, and configurations can be furnished, depending on quantities.
Aries reserves the right to change product specifications without notice.
A
LL DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances
+ .005 [.13] unless otherwise specified
Kapton is a registered trademark for DuPont
**Aries reserves the right to ship with
or without a polarization stripe unless
otherwise specified by customer
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
ORDERING INFORMATION
XX-XXXX-18X X X XX XX
Optional Suffix:
“HT”=High temperature cable insulation
Optional Suffix:
“TL” = Tin/Lead Plating
Optional Suffix:
“P”=Polarization stripe included
Cable Length: “L” in inches
Min. Cable Length = 2.00” (-002)
2” = -002-
2.5” = -002.5-
2.25” = -002.25-
2.125” = -002.125-
Jumper Series:
181: Male both ends
182: Male/Female (tin)
183: Female (tin) both ends
Bend Options:
“A” = Both ends bent 90°, same direction
“B” = One male end bent 90°
“C” = Both ends bent 90°, opposite direction
“D” = One female end bent 90°
XX-XXXX-182B
XX-XXXX-182BP
XX-XXXX -182BTL
XX-XXXX-182BHT
XX-XXXX-182BPTL
XX-XXXX-182BPHT
XX-XXXX-182BPTLHY
XX-XXXX-182C
XX-XXXX-182CP
XX-XXXX-182CTL
XX-XXXX-182CHT
XX-XXXX-182CPTL
XX-XXXX-182CPHT
XX-XXXX-182CPTLHT
XX-XXXX -182D
XX-XXXX-182DP
XX-XXXX-182DTL
XX-XXXX-182DHT
XX-XXXX-182DPTL
XX-XXXX-182DPHT
XX-XXXX-182DPTLHT
XX-XXXX-183A
XX-XXXX-183AP
XX-XXXX-183ATL
XX-XXXX-183AHT
XX-XXXX-183APTL
XX-XXXX-183APHT
XX-XXXX-183APTLHT
XX-XXXX-183C
XX-XXXX-183CP
XX-XXXX-183CTL
XX-XXXX-183CHT
XX-XXXX-183CPTL
XX-XXXX-183CPHT
XX-XXXX-183CPTLHT
XX-XXXX-183D
XX-XXXX-183DP
XX-XXXX-183DTL
XX-XXXX-183DHT
XX-XXXX-183DPTL
XX-XXXX-183DPHT
XX-XXXX-183DPTLHT
XX-XXXX-181A
XX-XXXX-181AP
XX-XXXX-181ATL
XX-XXXX-181AHT
XX-XXXX-181APTL
XX-XXXX-181APHT
XX-XXXX-181APTLHT
XX-XXXX-181B
XX-XXXX-181BP
XX-XXXX-181BTL
XX-XXXX-181BHT
XX-XXXX-181BPTL
XX-XXXX-181BPHT
XX-XXXX-181BPTLHT
XX-XXXX-181C
XX-XXXX-181CP
XX-XXXX-181CTL
XX-XXXX-181CHT
XX-XXXX-181CPTL
XX-XXXX-181CPHT
XX-XXXX-181CPTLHT
XX-XXXX-182A
XX-XXXX-182AP
XX-XXXX-182ATL
XX-XXXX-182AHT
XX-XXXX-182APTL
XX-XXXX-182APHT
XX-XXXX-182APTLHT
http://www.arieselec.com • info@arieselec.com
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
Bristol, PA
USA
TEL:
(215) 781-9956
FAX:
(215) 781-9845
abc
11019
REV.K
Page
1 of 3
【干货三剑客】A2B技术&AD9361之FM调频广播&电力方案齐发
剑客一:A2B精品视频——涵盖解决方案、技术资料...助您彻底了解A2B技术!{:1_113:} 奋战在汽车音频设计一线的攻城狮们,还在为汽车音频设计成本而苦恼?!还在为汽车音频性能不达标而暴走?! ......
EEWORLD社区 ADI 工业技术
BeagleBone Black设计: ZigBee模块通讯测试,活动倒数第二帖
本帖最后由 anananjjj 于 2014-6-25 13:40 编辑 眼看着活动的期限就到了!我感觉我能在结束前将我设想的基本功能实现,今天将BBB扩展版的串口1调通,并将其用于了ZigBee模块通讯上,Qt上位机 ......
anananjjj DSP 与 ARM 处理器
vxwork下手机开发,大家推荐好书好方法
c有点基础~~ windows下编程也过得去~~ 刚刚进入vxwork, 老大们推荐点好书, 不光是vxwork,实时系统, 大家觉得有用的多推荐~~...
liaozc 嵌入式系统
Allegro光绘问题
allegro在光绘文件add新的底片的时候会包含进所有的class,如何设置让新添加的底片和原有的底片里包含的class相同 ...
elivis PCB设计
转一遍感触很深的文章“程师之路”希望能引起大家的共鸣
来源:百度文库贡献者:ssf621 程师之路 恭喜,你选择开发工程师做为自已的职业 悲哀,你选择开发工程师做为自已的职业   本文所指的开发工程师,仅指程序开发人员和以数字电路开发为主的电 ......
tangguanglun 聊聊、笑笑、闹闹
一种新型高压大功率小信号放大电路
摘要:简要分析了UC3637双PWM控制器和IR2110的特点,工作原理。由UC3637和IR2110共同构建一种高压大功率小信号放大电路,并通过实验验证了其可行性。 关键词:小信号放大器;双脉宽调制;悬浮驱 ......
zbz0529 电源技术

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1158  935  1276  842  243  19  30  11  47  39 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved