• The 30R Series radial leaded device is designed to
provide overcurrent protection for low voltage (≤30V)
applications where space is not a concern and resettable
protection is preferred.
Features
• Cured, flame retardant
epoxy polymer insulating
material meets UL 94V-0
requirements
Agency Approvals
AGENCY
AGENCY FILE NUMBER
E183209
R50119318
• Fast time–to-trip
• RoHS compliant, Lead-
Free and Halogen-Free*
Applications
• USB hubs, ports
and peripherals
• Computers & peripherals
• Motor protection
• General electronics
• Automotive applications
Electrical Characteristics
Maximum Time
To Trip
Current
(A)
4.50
5.50
6.75
8.00
9.25
12.50
15.00
20.00
25.00
30.00
35.00
40.00
40.00
Time
(Sec.)
5.90
6.60
7
.30
8.00
8.70
10.30
10.80
12.70
14.50
16.00
17
.50
18.80
20.00
Resistance
R
min
(Ω)
0.070
0.050
0.040
0.030
0.030
0.020
0.020
0.010
0.010
0.005
0.005
0.005
0.005
R
1max
(Ω)
0.220
0.170
0.130
0.110
0.090
0.070
0.080
0.050
0.050
0.040
0.030
0.020
0.020
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Part Number
I
hold
(A)
0.90
1.10
1.35
1.60
1.85
2.50
3.00
4.00
5.00
6.00
7
.00
8.00
9.00
I
trip
(A)
1.80
2.20
2.70
3.20
3.70
5.00
6.00
8.00
10.00
12.00
14.00
16.00
18.00
V
max
(Vdc)
30
30
30
30
30
30
30
30
30
30
30
30
30
I
max
(A)
40
40
40
40
40
40
40
40
40
40
40
40
40
P
d
max.
(W)
0.6
0.7
0.8
0.9
1.0
1.2
2.0
2.5
3.0
3.5
3.8
4.0
4.2
Agency
Approvals
30R090
30R110
30R135
30R160
30R185
30R250
30R300
30R400
30R500
30R600
30R700
30R800
30R900
I
hold
= Hold current: maximum current device will pass without tripping in 23°C still air.
I
trip
= Trip current: minimum current at which the device will trip in 23°C still air.
V
max
= Maximum voltage device can withstand without damage at rated current (I
max
)
I
max
= Maximum fault current device can withstand without damage at rated voltage (V
max
)
P
d
= Power dissipated from device when in the tripped state at 23°C still air.
R
min
= Minimum resistance of device in initial (un-soldered) state.
R
1max
= Maximum resistance of device at 23°C measured one hour after tripping.
Caution:
Operation beyond the specified rating may result in damage and possible arcing
and flame.
* Effective January 1, 2010, all 30R PTC products will be manufactured Halogen Free (HF). Existing Non-Halogen Free 30R PTC products may continue to be sold, until supplies are depleted.
1. Introduction
Electronic scales are gradually replacing traditional measuring tools like springs and balances in everyday life, such as electronic price computing scales and electronic weigh...[详细]