MD100MHI
Series
Miniature, 1W SIP
Medical Approved
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
1W Output Power
•
3 kVAC rms Isolation
•
Reinforced Insulation
•
Miniature SIP Case
•
Single & Dual Outputs
•
12 Standard Models
•
2.0 MH MTBF
•
Industry Standard Pin-Out
•
EN 60950 Approved
•
EN 60601 Approved
Input
Parameter
Input Voltage Range
Input Filter
Reverse Polarity Input Current
Conditions
Min.
5 VDC Input
4.5
12 VDC Input 10.8
LC Filter
Typ.
5.0
12.0
Max.
5.5
13.2
0.3
Typ.
±1.0
Dual Output , Balanced Loads
±0.1
For Vin Change of 1%
±1.2
See Model Selection Guide
100
Over Line, Load & Temp.
±0.01
Momentary (0.5 Sec.)
Conditions
Min.
60 Seconds 3,000
Flash Tested for 1 Sec 4,500
500 VDC
10
100 kHz, 1V
50
Min.
-25
Typ.
Conditions
Min.
Max.
±3.0
±1.0
±1.5
150
200
15
±0.02
Units
VDC
A
Units
%
%
%
mV P - P
mV P - P
mV rms
%/°C
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz), See Note 2
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Max.
Units
VAC rms
VPk
G
pF
kHz
Units
°C
°C
°C
%
15
80
Typ.
20
100
Max.
+85
+90
+125
95
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
-50
Free Air Convection
RH, Non-condensing
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
0.87 x 0.30 x 0.49 Inches (22.0 x 7.5 x 12.5 mm)
Non-Conductive Black Plastic (UL94-V0)
0.13 Oz (3.9g)
Conditions
Min.
Typ.
Max.
MIL HDBK 217F, 25°C, Gnd Benign
2.0
UL 60601, UL 60950, EN 60601, EN 60950
Conditions
5 VDC Input
12 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
Typ.
Max.
9.0
29.0
260
650
Units
MHours
Reliability Specifications
Parameter
MTBF
Safety Approvals
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Units
VDC
°C
mW
Caution:
Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MD105MS-05HI
MD105MS-12HI
MD105MS-15HI
MD105MD-05HI
MD105MD-12HI
MD105MD-15HI
MD112MS-05HI
MD112MS-12HI
MD112MS-15HI
MD112MD-05HI
MD112MD-12HI
MD112MD-15HI
Voltage
(VDC)
Nominal
5
5
5
5
5
5
12
12
12
12
12
12
Range
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
Current
(mA)
Full-Load No-Load
303
291
295
303
267
287
126
121
123
126
108
117
55
55
55
55
55
55
30
30
30
30
30
30
Voltage
(VDC)
www.micropowerdirect.com
Output
Current
(mA, Max)
Current
(mA, Min)
Load
Regulation Efficiency
(%, Typ)
(%, Max)
10
8
8
10
8
8
10
8
8
10
8
8
66
66
66
66
72
73
66
66
66
66
74
75
Fuse Rating
Slow-Blow
(mA)
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0
12.0
15.0
±5.0
±12.0
±15.0
200.0
80.0
65.0
±100.0
±40.0
±35.0
200.0
80.0
65.0
±100.0
±40.0
±35.0
4.0
2.0
1.0
±2.0
±1.0
±1.0
4.0
2.0
1.0
±2.0
±1.0
±1.0
500
500
500
500
500
500
200
200
200
200
200
200
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
2. When measuring output ripple, it is recomended that an external 0.33
µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin for single
output units and from each output to common for dual output units.
3. Operation at no-load will not damage these units. However, they may not meet
all specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC
output. To do this, connect the load across the positive (+Vout) and negative
(-Vout) outputs and float the output common.
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
1
2
5
6
7
Single
+Vin
-Vin
-Vout
No Pin
+Vout
Dual
+Vin
-Vin
-Vout
Common
+Vout
NC: No Connection
Capacitive Load
Single Output
µF Max
Dual Output
µF Max
680
±220
Mechanical Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com