ILC-0805
Vishay Dale
Surface Mount, Multi Layer High Frequency
Ceramic Inductor
FEATURES
•
•
•
•
High reliability
Surface mountable
Reflow or wave solderable
Tape and reel packaging per EIA specifications:
4000 pieces on 7" reel
•
100 % lead (Pb)-free and RoHS compliant
RoHS
COM PLIANT
MECHANICAL SPECIFICATIONS
Solderability:
90 % coverage after 5 second dip in 235 °C
solder following 60 seconds preheat at 120 °C and type R
flux dip
Resistance to Solder Heat:
10 seconds in 260 °C solder,
after preheat and flux above.
Termination:
100 % tin
Terminal Strength:
0.6 kg (1.32 pounds) for 30 seconds
Beam Strength:
1.0 kg (2.20 pounds)
Flex:
0.0788" [2.0 mm] minimum mounted on 0.063"
[1.6 mm] thick PC board
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature:
- 55 °C to + 125 °C
Thermal Shock:
100 cycles, - 40 °C to + 85 °C
Humidity:
+ 40 °C, 85 % RH, 1000 hours at full rated current
Load Life:
85 °C for 1000 hours full rated current
STANDARD ELECTRICAL SPECIFICATIONS
INDUCTANCE
(nH)
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
TOL.
± 0.3 nH
± 0.3 nH
± 0.3 nH
± 0.3 nH
± 0.3 nH
± 0.3 nH
± 0.3 nH
± 0.3 nH
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
± 10 %, 5 %
TEST
Q (TYPICAL)
Q
FREQUENCY
(MIN.) L + Q (MHz) 100 MHz 300 MHz 500 MHz 800 MHz 1000 MHz 1800 MHz
10
10
10
12
12
12
12
15
15
15
15
15
15
15
18
18
18
18
18
18
18
18
18
13
13
13
12
12
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
50
50
50
50
50
21
18
18
19
16
18
18
20
20
21
20
21
22
24
23
23
24
23
23
23
25
24
23
22
22
23
20
20
39
35
33
36
29
33
34
38
39
40
38
39
42
44
43
42
43
41
41
42
42
41
37
33
34
34
23
19
57
49
46
50
40
46
46
51
52
54
51
52
55
57
55
53
54
50
49
48
45
41
37
29
26
20
-
-
61
55
53
56
47
54
55
60
63
63
60
60
63
63
60
58
55
47
43
39
30
-
-
-
-
-
-
-
68
59
58
60
51
60
60
66
69
70
67
67
72
72
69
68
60
47
41
38
-
-
-
-
-
-
-
-
50
50
60
70
50
50
56
48
26
45
36
37
23
14
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SRF (MHz)
MIN
4000
4000
4000
4000
4000
4000
3500
3200
2800
2400
2100
1900
1600
1500
1400
1300
1200
1000
900
800
700
600
600
500
500
400
350
300
TYP
6000
6000
6000
6000
6000
6000
6000
5400
4200
3700
3100
3000
2600
2300
2100
1800
1700
1400
1200
1100
900
800
800
700
700
600
550
480
DCR
MAX.
(OHMS)
0.10
0.10
0.10
0.10
0.13
0.15
0.20
0.23
0.25
0.28
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.90
0.90
0.95
1.0
1.1
1.2
1.3
RATED
CURRENT
(mA)
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
DIMENSIONS
in inches [millimeters]
Ceramic
Body
0.035 ± 0.008
[0.90 ± 0.2]
0.020 ± 0.001
[0.50 ± 0.3]
0.079 ± 0.008
[2.0 ± 0.2]
0.049 ± 0.008
[1.25 ± 0.2]
DESCRIPTION
ILC-0805
MODEL
10 nH
INDUCTANCE
VALUE
± 10 %
INDUCTANCE
TOLERANCE
ER
PACKAGE
CODE
e3
JEDEC LEAD (Pb)-FREE
STANDARD
GLOBAL PART NUMBER
I
L
C
0
8
SIZE
0
5
E
R
1
0
N
K
TOL.
PRODUCT FAMILY
PACKAGE
CODE
INDUCTANCE
VALUE
www.vishay.com
92
For technical questions, contact: magnetics@vishay.com
Document Number: 34162
Revision: 14-Mar-06
Legal Disclaimer Notice
Vishay
Notice
Specifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc.,
or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's
terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express
or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness
for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify Vishay for any damages resulting from such improper use or sale.
Document Number: 91000
Revision: 08-Apr-05
www.vishay.com
1