Inner Shield Trade Name Type Inner Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
24
Inner Shield Drain Wire Stranding:
Inner Shield Drain Wire Conductor Material:
7x32
TC - Tinned Copper
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material
1
2
Beldfoil®
Braid TC - Tinned Copper
Coverage (%)
65
Tape Aluminum Foil-Polyester Tape 100
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.048
Overall Cable
Overall Nominal Diameter:
0.343 in.
Pair
Pair Color Code Chart:
Number Color
1
2
Black & Red
Black & White
Mechanical Characteristics (Overall)
Operating Temperature Range:
Non-UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-40°C To +60°C
60°C (UL AWM Style 2493)
53 lbs/1000 ft.
63 lbs.
3.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
CM
CM
Page 1 of 3
09-11-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8162 Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 & Digital
CEC/C(UL) Specification:
AWM Specification:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CM
UL Style 2493 (300 V 60°C)
Yes
Yes
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
UL1581 Vertical Tray
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
100
Nom. Inductance:
Inductance (µH/ft)
.228
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
12.5
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
22
Nominal Velocity of Propagation:
VP (%)
78
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
24.0
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
4.3
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C:
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
1.8 Amps per conductor @ 25°C
18 Ohm/1000 ft
Notes (Overall)
Notes:
Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush
resistance and light weight.
Put Ups and Colors:
Item #
8162 060100
8162 0601000
8162 060500
Notes:
C = CRATE REEL PUT-UP.
Putup
100 FT
1,000 FT
500 FT
Ship Weight
6.200 LB
57.000 LB
30.000 LB
Color
CHROME
CHROME
CHROME
C
C
Notes
Item Desc
2 FS PR #24 FHDPE SH PVC
2 FS PR #24 FHDPE SH PVC
2 FS PR #24 FHDPE SH PVC
Page 2 of 3
09-11-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8162 Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 & Digital
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).