General Purpose Relays
SCHRACK
Safety Relay SR6 D/M
n
n
n
n
4 pole safety relay with either
2 NO+2 NC or 3 NO+1 NC contacts
Forcibly guided contacts according to EN 50205
Rated current 8 A
High insulation distances for safe separation of
electrical circuits
Applications
Emergency shut-off, press control, machine control, elevator
and escalator control, safety modules
F0206-ED
Approvals
V
REG.-Nr. 128935,
Z
E214024,
T
968/EL 350.04/09
Technical data of approved types on request
Contact data
3 NO contacts and 1 NC contact
or
2 NO contacts and 2 NC contacts
Contact set
single contact, forcibly guided
type A according to EN 50205
Type of interruption
micro disconnection
Rated voltage / max. switching voltage AC
250 / 400 VAC
Rated current
8A
Maximum breaking capacity AC
2000 VA
Contact material
AgSnO
2
Minimum contact load
10 mA / 5 V
Contact resistance
w
100 mOhm / 1 A / 24 VDC
w
20 Ohm / 10 mA / 5 VDC
Rated frequency of operation with / without load
6 min
-1
/ 150 min
-1
Contact ratings
Type Contact Load*)
EN60947-5-1
SR6
1 NO
SR6
1 NO
*) load on one pole
Contact configuration
Ambient
temp. [°C]
23°C
23°C
Cycles
6,050
6,050
IEC 947-5-1 (AC15) utilization category 250 VAC / 5 A
IEC 947-5-1 (DC13) utilization category 24 VDC / 6 A
Coil data
Rated coil voltage range DC coil
Operative range to IEC 61810
5...110 VDC
2
Coil versions, DC-coil
Coil
Rated
Operate
Release / Reset
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
005
5
3.8
0.5
21+10%
1190
006
6
4.5
0.6
30+10%
1200
009
9
6.8
0.9
68+10%
1191
012
12
9.0
1.2
120+10%
1200
018
18
13.5
1.8
270+10%
1200
021
21
15.8
2.1
368+10%
1198
024
24
18.0
2.4
480+10%
1200
036
36
27.0
3.6
1080+10%
1200
040
40
30.0
4.0
1333+10%
1200
048
48
36.0
4.8
1920+10%
1200
060
60
45.0
6.0
3000+12%
1200
110
110
82.5
11.0
10080+12%
1200
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
SCHRACK
Safety Relay SR6 D/M
(Continued)
Insulation
Dielectric strength coil-contact circuit
3000 V
rms
open contact circuit
1500 V
rms
adjacent contact circuits 3000 / 4000 V
rms
(in longitudinal direction)
Clearance / creepage coil-contact circuit
W
5.5 / 5.5 mm
adjacent contact circuits
W
5.5 / 5.5 mm
W
15 / 15 mm (in longitudinal direction)
Material group of insulation parts
IIIa
Tracking index of relay base
PTI 250
Insulation to IEC 61810-1
Type of insulation coil-contact circuit
basic
open contact circuit
micro disconnection
adjacent contact circuits reinforced (in longitudinal dir)
Rated insulation voltage
250 V
Pollution degree
2
Rated voltage system
230 / 400 V
Overvoltage category
III
Insulation to EN 50178
Type of insulation coil-contact circuit
reinforced
adjacent contact circuits
reinforced
PCB layout / terminal assignment
Bottom view on solder pins
2 NO+2 NC versions
S0368-CI
S0368-CJ
Other data
Mechanical endurance
10x10
6
cycles
Material
RoHS - Directive 2002/95/EC
compliant as per product date code 0407
Environment
Ambient temperature range
-25...+70°C
Vibration resistance (function) NO / NC contact > 8 / 2.5 g, 10....200 Hz
Shock resistance (function) NO / NC contact > 10 / 2.5 g, 16 ms half sine
Category of protection
RT III
1)
Processing
Resistance to soldering heat
260°C / 5 s
Relay weight
30 g
Packaging unit
10 pcs
1
)
3 NO + 1 NC version
S0368-CK
please contact technical support for washing parameters
Accessories
PCB socket and hold down clip
contact technical support
S0368-CL
Dimensions
S0367-DB
2
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
SCHRACK
Safety Relay SR6 D/M
(Continued)
Product key
Type
SR6
Safety Relay SR6 D/M
Contact configuration
D
2 NO + 2 NC contacts (2 form A + 2 form B)
M
3 NO + 1 NC contacts (3 form A + 1 form B)
Contact material
4
AgSnO
2
Coil
Coil code = rated coil voltage (e.g. 024=24 VDC)
Other types on request
Typical product key
SR6
D
4
012
Product key
SR6D4012
SR6D4018
SR6D4021
SR6D4024
SR6D4040
SR6D4110
SR6M4006
SR6M4012
SR6M4018
SR6M4021
SR6M4024
SR6M4110
Type
4-pole
safety relay
Contact configuration
2 NO + 2 NC
contacts
Contact material
AgSnO
2
3 NO + 1 NC
contacts
Coil
12 VDC
18 VDC
21 VDC
24 VDC
40 VDC
110 VDC
6 VDC
12 VDC
18 VDC
21 VDC
24 VDC
110 VDC
Part number
1415078-1
7-1415354-1
8-1415353-1
6-1415027-1
9-1415366-1
1415062-1
6-1415053-1
7-1415353-1
1415354-1
6-1415353-1
3-1415353-1
1-1415354-1
3
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.