Embedded Power for
Business-Critical Continuity
Output Current
Output
Voltage
+5 V (IA)
+12 V (IB)
–12 V
+5 V (IA)
+15 V (IB)
–15 V
+5 V
+24 V
+12 V
+5 V (IA)
+24 V (IB)
+5 V (IA)
+12 V (IB)
+5 V
+12 V
+15 V
+24 V
Max (1)
7.5 A
2.5 A
0.65 A
7.5 A
2.2 A
0.65 A
7.0 A
1.5 A
0.7 A
7 A
2 A
7 A
2.5 A
10 A
5.4 A
4.4 A
2.7 A
Peak (3)
9.1 A
3.3 A
0.81 A
9.1 A
2.9 A
0.85 A
9.1 A
2.6 A
1.0 A
9.1 A
2.6 A
9.1 A
3.3 A
13 A
7 A
5.7 A
3.5 A
Fan (10)
8 A
3 A
0.8 A
8 A
2.5 A
0.8 A
8.0 A
2.0 A
1.0 A
8 A
2 A
8 A
3 A
12 A
6.5 A
5.3 A
3.5 A
Ripple (4)
50 mV
150 mV
120 mV
50 mV
150 mV
150 mV
50 mV
240 mV
120 mV
50 mV
240 mV
50 mV
150 mV
50 mV
120 mV
150 mV
240 mV
Total
Non-harmonic
Harmonic
Regulation (6)
Corrected
Corrected
±2.0%
NLP65-7608J
NLP65-9608J
±5.0%
±5.0%
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±2.0%
±5.0%
±2.0%
±2.0%
±2.0%
±2.0%
NLP65-7605J
NLP65-7612J
NLP65-7615J
NLP65-7624J
NLP65-9605J
NLP65-9612J
NLP65-9615J
NLP65-9624J
NLP65-X605GJ
NLP65-X612GJ
NLP65-X615GJ
NLP65-X624GJ
NLP65-7629J
NLP65-9629J
NLP65-X629GJ
NLP65-7620J
NLP65-9620J
NLP65-X620GJ
NLP65-3322J
(15)
NLP65-7610J
NLP65-9610J
NLP65-X610GJ
Ground
Pin (12, 14, 17)
NLP65-X608GJ
Rev.11.06.08_102
NLP65 Series
of 4
Notes
1
Natural convection cooling. Models NLP65-X629J, NLP65-X608J, NLP65-
X610J must not exceed 62.5 Watts continuous output power with natural
convection. Model NLP65-X620J not to exceed 65 Watts continuous output
power with natural convection. Model NLP65-3322J must not exceed 60 Watts
continuous output power with natural convection.
2
When the input voltage is less than 90 Vac the operating temperature range is
0
°
C to +40
°
C. The ripple and regulation specifications may not be met.
3
Peak output current lasting less than 60 seconds with duty cycle less than 5%.
During peak loading, output voltage may exceed total regulation limits.
4
Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6 inch twisted
pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic
capacitor.
5
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5
Hz to 500 Hz.
6
A minimum load on the main output is required for proper start up. For
multiple outputs and single +5V output, the minimum load on the +5 V is
0.2 A. For single outputs greater than +5 V the minimum load is 0.1 A. To
maintain stated regulation then:
for single output units
I ≥ 0.2 A
for multiple output units
0.25 ≤ I(A)/I(B) ≤ 5, for I(A) ≥ 0.2 A.
7
For optimum reliability, no part of the heatsink should exceed 120
o
C, and no
semiconductor case temperature should exceed 130
o
C.
8
CAUTION: Allow a minimum of 1 second after disconnecting line power when
making thermal measurements.
9
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
10
Maximum continuous output power for all multiple output models must not
exceed 75 Watts (70 watts for NLP65-3322J)with 20 CFM forced air cooling.
11
Conducted emissions testing were performed using the standard EN55022 set-
up with a stand alone NLP65 unit placed on a grounded metal plate with a line
choke on the AC input and ground wires (i.e. the wires are looped through an
EMI suppression toroid).
For system compliance it is usually necessary to install an ‘off-the-shelf’ AC
inlet with an integral line filter in the system chassis or to install a line choke
on the input wires as close as possible to AC entry point of the system chasssis.
Please contact the applications group for assistance with EMI compliance.
12
The NLP65 units with the suffix ‘G’ is the ground pin and ground choke option.
J2, L6 and JP10 are included. J2 is a safety agency approved grounding pin, L6
is a ground choke and JP10 is a jumper. This option is intended for use in non-
metallic chassis applications where grounding is not possible via the mounting
screws. The ground choke is provided to assist system EMC compliance. When
performing conducted emissions testing on stand alone units, the ‘G’ option
is required to meet level B. To order simply add the suffix ‘G’ to the standard
model number, e.g. NLP65-7608GJ, NLP65-9608GJ. This option is available for
both the PFC and non-PFC versions.
13
All models require a minimum mounting stand-off of 0.25 inches (6.35 mm) in
the end use product.
14
The NLP65-9608J is available with an enclosure. To order an enclosed version,
see model numbering options below.
15
No PFC version, EN61000-3-2 is not applicable to this model.
16
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
17
NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.powerconversion.com.
Model Numbering Options
1
The enclosure version includes: IEC connector, on/off switch, wire harness
output connector and fitted cover. To order, please add the suffix ‘E’ the model
number, e.g. NLP65-9608EJ. See NLP65 enclosure for details.
2
A Safety earth ground pin and ground choke are available as an option.
To order, please add the suffix ‘G’ the model number, e.g. NLP65-X608GJ.
3
To order an enclosure kit (unfitted), order the part number LPX80.
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
5.00
(127.00)
4.550
(115.57)
0.225
(5.715)
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Rev.11.06.08_102
NLP65 Series
4 of 4
Europe (UK)
J1
3
1
N
L
2.550
(64.770)
J3
1
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
3.00
(76.20)
J2
C19
T1
6
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
Mounting
Hole Diameter
0.156 (4.00)
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
TOLERANCE: .xxx
.xx
ALL DIMENSIONS IN INCHES (mm)
0.005"
0.02"
www.powerconversion.com
techsupport.embeddedpower@
emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
INPUT
PIN CONNECTIONS
J1
Pin 1
Pin 2
Pin 3
Pin 1
AC Line
No Pin
AC Neutral
Safety Ground
Emerson Network Power.
The global leader in enabling
business-critical continuity.
Input and output connectors Mating connectors
AC (J1) connector type
Molex 26-60-4030 type.
DC (J3) connector type
Molex 26-60-4060 type.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals.
DC (J3) mating connector type
Molex 09-50-3061 with Molex 2478 phosphor
bronze crimp terminals or equivalent.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
J2 (ON ‘G’ SUFFIX ONLY)
Note: The input and output connectors are the same as those used on NFS40,
NFN40, NAL40, NAN40 and NLP40.
J3
OUTPUT PIN CONNECTIONS
SINGLE
DUAL
V (A)
V (A)
V (A)
Return
Return
Return
V (B)
V (A)
V (A)
Return
Return
N/C
TRIPLE
V (B)
V (A)
V (A)
Return
Return
V (C)
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2008
Emerson Electric Co.