Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8765 Multi-Conductor - Audio, Control and Instrumentation Cable
For more Information
please call
1-800-Belden1
Description:
22 AWG solid conductors, PVC insulation, tinned copper, twisted pairs, individually shielded w/Beldfoil®
(100% coverage), 22 AWG solid TC drain wire, overall PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
11
22
Solid
TC - Tinned Copper
Insulation
Insulation Material:
Insulation Material
Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.3302
Insulation Resistance:
200 megaohms/1000 ft. @ 500V DC
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material
Beldfoil® (Z-Fold®)
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
22
Inner Shield Drain Wire Stranding:
Inner Shield Drain Wire Conductor Material:
Solid
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 1.016
Overall Cable
Overall Nominal Diameter:
11.938 mm
Pair
Pair Color Code Chart:
Number Color
1
2
3
4
5
6
7
8
9
10
11
Black & Red
Black & White
Black & Green
Black & Blue
Black & Yellow
Black & Brown
Black & Orange
Red & White
Red & Green
Red & Blue
Red & Yellow
Pair Lay Length & Direction:
Page 1 of 3
02-01-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8765 Multi-Conductor - Audio, Control and Instrumentation Cable
Lay Length (mm) Twists/ft. (twist/m)
44.449825
22.639
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-20°C To +80°C
80°C (UL AWM Style 2464)
192.275 Kg/Km
1423.420 N
238.760 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
AWM Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
UL Style 2464 (300 V 80°C)
Yes
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
Flame Test
C(UL) Flame Test:
FT4
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.62339
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
131.24
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/m)
252.637
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
54.7927
Ind. Pair Nominal Shield DC Resistance @ 20
Deg. C:
Max. Operating Voltage - UL:
Voltage
300 V RMS (UL AWM Style 2464)
39.372 Ohm/km
Max. Recommended Current:
Current
1.5 Amps per conductor @ 25°C
Related Documents:
Page 2 of 3
02-01-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8765 Multi-Conductor - Audio, Control and Instrumentation Cable
No related documents are available for this product
Put Ups and Colors:
Item #
Putup
Ship Weight
Color
Notes
Item Desc
Revision Number: 1
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 04-17-2008
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
02-01-2012