SERIES:
VSCP-1K5
│
DESCRIPTION:
AC-DC POWER SUPPLY
FEATURES
• up to 1,500 W continuous power
• universal input (90~260 Vac / 130~370 Vdc)
•
•
•
•
•
•
•
•
•
single output from 9~60 V
programmable output voltage
power factor correction (98%)
current sharing capable
power good, remote sense, remote on/off control
built-in DC fan
over load, over voltage, over temperature, and short circuit protections
UL and TUV safety approvals
efficiency up to 90%
RoHS
N
TI
(Vdc)
max
(A)
max
(W)
MODEL
VSCP-1K5-09
VSCP-1K5-12
VSCP-1K5-15
VSCP-1K5-18
VSCP-1K5-24
VSCP-1K5-36
VSCP-1K5-48
VSCP-1K5-60
Notes:
output
voltage
1
output
current
2
N
U
output
power
ripple
and noise
3
max
(mVp-p)
9
88 / 166
66 / 125
1,500
1,500
12
15
53 / 100
33 / 62
1,500
18
44 / 83.3
1,500
24
1,500
36
22 / 41.6
16 / 31
13 / 25
1,500
48
1,500
O
60
1,500
1. output voltage is measured at output power connector
2. maximum current is measured at 100 ~ 120 V input / 200 ~ 240 V input
3. ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1
μF
ceramic capacitor and a 22
μF
electrolytic capacitor in parallel
IS
C
PART NUMBER KEY
VSCP-1K5 -
XX
Base Number
Output Voltage
D
cui.com
ED
efficiency
typ
(%)
90
120
150
150
150
150
150
150
83
84
85
85
88
88
89
90
For more information, please visit the product page.
CUI Inc
│
SERIES:
VSCP-1K5
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
08/28/2012
│
page
2 of 6
INPUT
parameter
voltage
frequency
current
inrush current
power factor correction
at 230 Vac
peak measured at 230 Vac, cold start
at 230 Vac, full load
conditions/description
min
90
130
47
9
typ
max
260
370
63
units
Vac
Vdc
Hz
A
A
OUTPUT
parameter
temperature coefficient
hold-up time
adjustability
programming
conditions/description
0 ~ 50°C
230 Vac at full load
adjustable with built-in trim pot
min
N
U
-12
25
min
110
typ
min
typ
min
0
-20
20
10
10
typ
output voltage programmable through external
1 ~ 5 V control voltage on VCI. Control voltage
can also be obtained from VCO via a 470 KΩ pot.
see application diagrams
remote sense
remote inhibit
current sharing
Designated as (VS+) and (VS-). Total voltage compensation from cable losses with respect to the main
output.
Designated as (INH), requires a low signal to inhibit the output.
Designated as (PAR), use in parallel for forced current sharing function.
PROTECTION
parameter
over voltage protection
over current protection
1
Notes:
conditions/description
N
TI
cui.com
current limiting 3 times with auto recovery before
shutdown
1. Protection mode sends a pulse, waits 1.5 seconds, sends second pulse, waits 3 seconds, sends third pulse, waits 5 seconds. If overload is still present, the unit will
shutdown.
SAFETY & COMPLIANCE
parameter
safety approvals
EMI/EMC
leakage current
O
conditions/description
TUV EN 60950, UL/cUL 1950
IS
C
EN 55022, EN 61000-4-(2,3,4,5,6,8,11), EN 61000-3-(2,3), ENV50204
at 240 Vac
7.0
mA
yes
RoHS compliant
ENVIRONMENTAL
parameter
operating temperature
operating humidity
storage humidity
vibration
storage temperature
conditions/description
D
for 60 minutes, each axis
ED
120
0.98
typ
max
12
+3
100
units
%/°C
ms
%
%
±0.04
max
135
units
%
max
units
max
50
85
90
95
200
units
°C
°C
%
%
Hz
For more information, please visit the product page.
CUI Inc
│
SERIES:
VSCP-1K5
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
08/28/2012
│
page
3 of 6
DERATING CURVES
100
Load (%)
80
60
50
40
20
-25
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
D
IS
C
cui.com
O
N
TI
N
U
≈
ED
≈
For more information, please visit the product page.
CUI Inc
│
SERIES:
VSCP-1K5
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
08/28/2012
│
page
4 of 6
MECHANICAL
parameter
weight
dimensions
11.42 x 4.72 x 5.22 (290 x 120 x 132.5 mm)
conditions/description
min
typ
4.5
max
units
Kg
inch
MECHANICAL DRAWING
units: mm[inch]
tolerance: ±1.0mm unless otherwise specified
132.50 5.217
290.00 11.417
N
U
200.00 7.874
200.00 7.874
251.00 9.882
120.00 4.724
103.00 4.055
M3(NUT)X3H
(4 PLCS)
IS
C
O
M3(NUT)X3H
(4 PLCS)
89.00 3.504
D
N
TI
LOGIC CONNECTOR
output voltage remote sense+
output voltage remote sense-
command input voltage for output programming
5~10 Vdc reference for output programming
power failure detected
power good signal
current sharing / parallel function
return / output ground
inhibit / remote on-off
cui.com
VS-
VCI
FAL
PG
PAR
GND
INH
1
2
3
4
5
6
7
8
9
VS+
VCO
#6-32
(4 PLCS)
ED
26.50 1.043