SPECIFICATION
TACT SWITCH
1.Temperature range:
1.1 Storage Temperature range -30℃ to 80℃
1.2 OperatingTemperature range -20℃ to 70℃
1.3 Test Conditions
1.3.1Tests and measurements shall be made in the following standard clnditions
unless otherwise specified:
Normal temperature (temperature 5 to 35℃)
Normal humidity (relative humidity 45 to 85%)
Normal pressure (pressure 860 to 1060 mbars)
PAGE
1/5
1.3.2 In case any question arises from the judgement made, tests shall be conducted
in the following conditions:
Temperature
Relative humidity
Pressure
(20±2℃)
(65±5%)
(860 to 1060 mbars)
2. Appearance、 Structure and Dimension:
2.1 Appearance : There shall be no defects that affect the serviceability of the product.
2.2 Structure and Dimension : Shall conform to the assembly drawings.
3. Rating : DC 12V 50㎃ Max
4. Electrical Performance
PROPERTY
Contact
4.1
Resistance
TEST CONDITIONS
PERFORMANCE
Applying astatic load twice the actuating force to the
center of the stem,measurements shall be made with a 100 mΩ max
1 kHz small-current contact resistance meter.
Measurements shall be made following application of
DC100V potintial across terminals and across terminals 100 MΩ min
and frame for one minute.
Insulation
4.2
resistance
Dielectric
4.3 witstanding
voltage
AC250V(50Hz or60Hz) shall be applied across
terminals and across terminals and frame for one
minute.
There shall be no
breakdown
APPD
CHKD
DSGN
TITLE
JT-1140 SERIES
JT0010-01
DOCUMENT NO.
ZONE SYMB DATE APPD CHKD DSGD
SPECIFICATION
TACT SWITCH
PAGE
2/5
PROPERTY
TEST CONDITIONS
Lightly striking the center of the stem at a rate
encountered in normal use (3 to 4 operations per
sec.),
Bounce shall be tested at “ON”and “OFF”.
Sw tch
i
switch
PERFORMANCE
4.4 Bounce
5v
5k
ohm
5 m sec max.
"OFF"
"O
FF"
"ON"
"O "
N
5. Mechanical Performance
PROPERTY
TEST CONDITIONS
PERFORMANCE
160 ± 50 gf
260 ± 50 gf
Placing the switch such that the direction of switch
operation is vertical and then gradually increasing the
5.1 Actuating Force load applied to the center of the stem, the maximum
load required for the stem to come to a stop shall be
measured.
Placing the switch such that the direction of switch
operation is vertical and then applying a static load
twice the actuating force to the center of the stem,the
travel distance for the stem to come to a stop shall be
measured.
The sample switch is installed such that the direction
of switch operation is vertical and,upon depression of
the stem in its center the whole travel distance ,the
force of the stem to return to its free position shall be
measured.
Placing the switch such that the direction of switch
operation is vertical, the maximum force to withstand a
pull applied oppsite to the direction of stem operation
shall be measured.
5.2 Travel
0.25±0.1mm
5.3 Return Force
45 gf min
5.4 Stem Strength
3 kgf
APPD
CHKD
DSGN
TITLE
JT-1140 SERIES
JT0010-01
DOCUMENT NO.
ZONE SYMB DATE APPD CHKD DSGD
SPECIFICATION
TACT SWITCH
6. Environmental Performance
PROPERTY
TEST CONDITIONS
Following the test set forth below the sample shall be
left in normal temperature and humidity conditions for
one hour before measurements are made:
(1) Temperature: -30±2℃
(2)
Time: 96 hours
(3) Water drops shall be removed.
Following the test set forth below the sample shall be
left in normal temperature and humidity conditions for
one hour before measurements are made:
(1)Temperature: 80±2℃
(2)
Time: 96 hours
Following the test set forth below the sample shall be
left in normal temperature and humidity conditions for
one hour before measurements are made:
(1)
Temperature: 60±2℃
(2) Relative humidity: 90 to 95%
(3)
Time: 96 hours
(4) Water drops shall be removed.
PAGE
3/5
PERFORMANCE
Resistance to
6.1
Low
Temperatures
Item 4.1、4.2、4.3、4.4
Item 5.1
Item 5.2
Heat
6.2 Resistance
Item 4.1、4.2、4.3、4.4
Item 5.1
Item 5.2
Contact resistance:500mΩ
max
Insulation resistance:
100 MΩ min.
Item 4.3
Item 5.1
Item 5.2
6.3
Moisture
Resistance
7. Endurance Performance
PROPERTY
TEST CONDITIONS
Measurements shall be made following the test set
forth below:
(1)DC 5V 5mA resistive load. DC 5V 5mA
(2)Rate of operation:2 to 3 operations per second
(3)Depression: 160 / 250 gf
(4)Cycles of operation:
As per individual manufactured drawing.
PERFORMANCE
Contact resistance: 1Ω max.
Insulation resistance :
100MΩ min.
Actuating force:
+ 30 %or- 30%of initial
force.
Item 4.3 Item 5.2
7.1 Operating Life
7.2
Vibration
Resistance
Measurements shall be made following the test set
forth below:
(1)Range of oscillation:10 to 55Hz
(2)Amplitude,pk-to-pk:1.5 mm
(3)Cycle of sweep: 10-55-10Hz in one minute,approx.
Item 4.1、4.2、4.3、4.4
(4)Mode of sweep :Logarithmically sweep or uniform
Item 5.1
sweep.
Item 5.2
(5) Direction of oscillation:
Three mutually perpendicular directions,including the
directionof stem travel.
(6) Duration of testing:
2 hours each ,for a total of 6hours.
APPD
CHKD
DSGN
TITLE
JT-1140 SERIES
JT0010-01
DOCUMENT NO.
ZONE SYMB DATE APPD CHKD DSGD
SPECIFICATION
TACT SWITCH
PAGE
4/5
PROPERTY
TEST CONDITIONS
Measurements shall be made following the test set
forth below:
(1)Acceleration:80g
(2)Cycles of test :3 cycles each in 6directions, for a
total of 18cycles
PERFORMANCE
Impact Shock
7.3
Resistance
Item 4.1、4.2、4.3、4.4
Item 5.1
Item 5.2
8. Environmental Endurance
PROPERTY
TEST CONDITIONS
Foeeowing ten cycles of high temperature test .Saupee
shall be Place in Normae temperature and humidity
Conditious for one hour before measurements are
made. During this test, water drops shall be removed.
(1) Temperature:-30℃~80℃
(2) Cycling:10 cycles
High
8.1 Temperature
Cycling
+
℃
80
PERFORMANCE
1 Cycl e
Item 4.1、4.2、4.3、4.4
Item 5.1
Item 5.2
-30
℃
2H
1H
2H
1H
APPD
CHKD
DSGN
TITLE
JT-1140 SERIES
JT0010-01
DOCUMENT NO.
ZONE SYMB DATE APPD CHKD DSGD