The SY10/100E154 offer five 2:1 multiplexers followed
by latches with differential outputs, designed for use in
new, high-performance ECL systems. The two external
Latch-Enable signals (LEN
1
, LEN
2
) are gated through a
logical OR operation before use as control for the five
latches. When both LEN
1
and LEN
2
are at a logic LOW, the
latches are transparent, thus presenting the data from the
multiplexers at the output pins. If either LEN
1
or LEN
2
(or
both) are at a logic HIGH, the outputs are latched.
The multiplexer operation is controlled by the SEL(Select)
signal which selects one of the two bits of input data at each
mux to be passed through.
The MR (Master Reset) signal operates asynchronously
to make all Q outputs go to a logic LOW.
s
Dual latch-enables
s
Fully compatible with industry standard 10KH,
100K ECL levels
s
Internal 75K
Ω
input pulldown resistors
s
Fully compatible with Motorola MC10E/100E154
s
Available in 28-pin PLCC package
BLOCK DIAGRAM
PIN NAMES
Pin
Function
Input Data a
Input Data b
Data Select Input
Latch Enables
Master Reset
True Outputs
Inverted Outputs
V
CC
to Output
D
0a
MUX
D
0b
D
1a
MUX
D
1b
D
2a
MUX
D
2b
D
3a
MUX
D
3b
D
4a
MUX
D
4b
SEL
LEN
1
LEN
2
MR
SEL
SEL
SEL
SEL
SEL
D
Q
Q
0
Q
0
D
0a
–D
4a
D
0b
–D
4b
SEL
E Q
NR
D
Q
Q
1
Q
1
LEN
1
, LEN
2
MR
Q
0
–Q
4
Q
0
–Q
4
E Q
NR
D
Q
Q
2
Q
2
V
CCO
E Q
NR
D
Q
Q
3
Q
3
E Q
NR
D
Q
Q
4
Q
4
E Q
N R
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
Rev.: E
Amendment: /0
1
Issue Date: March 2006
Micrell, Inc.
SY10E154
SY100E154
PACKAGE/ORDERING INFORMATION
V
CCO
Ordering Information
(1)
Q
4
Q
4
D
4b
D
4a
D
3b
D
3a
25 24 23 22 21 20 19
Part Number
18
17
Package
Type
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
Operating
Range
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Package
Marking
SY10E154JC
SY10E154JC
SY100E154JC
SY100E154JC
SY10E154JZ with
Pb-Free bar-line indicator
SY10E154JZ with
Pb-Free bar-line indicator
SY100E154JZ with
Pb-Free bar-line indicator
SY100E154JZ with
Pb-Free bar-line indicator
Lead
Finish
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Matte-Sn
Matte-Sn
Matte-Sn
Matte-Sn
SEL
LEN
1
LEN
2
V
EE
MR
D
0a
D
0b
26
27
28
1
2
3
4
5
6
7
8
9
10 11
Q
3
Q
3
V
CC
Q
2
Q
2
Q
1
Q
1
SY10E154JC
SY10E154JCTR
(2)
SY100E154JC
SY100E154JCTR
(2)
SY10E154JZ
(3)
SY10E154JZTR
(2, 3)
SY100E154JZ
(3)
SY100E154JZTR
(2, 3)
Notes:
PLCC
TOP VIEW
J28-1
16
15
14
13
12
D
1a
D
1b
V
CCO
Q
0
D
2a
D
2b
28-Pin PLCC (J28-1)
Q
0
1. Contact factory for die availability. Dice are guaranteed at T
A
= 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
2
Micrel, Inc.
SY10E154
SY100E154
TRUTH TABLES
SEL
H
L
Data
a
b
LEN
1
L
H
X
LEN
2
L
X
H
Latch
Transparent
Latched
Latched
DC ELECTRICAL CHARACTERISTICS
V
EE
= V
EE
(Min.) to V
EE
(Max.); V
CC
= V
CCO
= GND
T
A
= 0
°
C
Symbol
I
IH
I
EE
Parameter
Input HIGH Current
Power Supply Current
10E
100E
—
—
76
76
91
91
—
—
76
76
91
91
—
—
76
87
91
105
—
—
150
T
A
= +25
°
C
—
—
150
T
A
= +85
°
C
Max.
150
Unit
µA
mA
Condition
—
—
—
—
Min. Typ. Max. Min. Typ.
Max. Min. Typ.
AC ELECTRICAL CHARACTERISTICS
V
EE
= V
EE
(Min.) to V
EE
(Max.); V
CC
= V
CCO
= GND
T
A
= 0
°
C
Symbol
t
PD
Parameter
Propagation Delay to Output
D
SEL
LEN
MR
Set-up Time
D
SEL
Hold Time
D
SEL
Reset Recovery Time
Minimum Pulse Width, MR
Within-Device Skew
Rise/Fall Time
20% to 80%
T
A
= +25
°
C
T
A
= +85
°
C
Max.
700
925
750
800
ps
300
500
300
200
800
400
—
300
100
250
–100
–250
600
—
50
475
—
—
—
—
—
—
—
800
300
500
300
200
800
400
—
300
100
250
–100
–250
600
—
50
475
—
—
—
—
—
—
—
800
300
500
300
200
800
400
—
300
100
250
–100
–250
600
—
50
475
—
—
ps
—
—
—
—
—
800
ps
ps
ps
ps
—
—
1
—
—
—
Unit
ps
325
475
350
450
500
650
500
600
700
925
750
800
325
475
350
450
500
650
500
600
700
925
750
800
325
475
350
450
500
650
500
600
Condition
—
Min. Typ. Max. Min. Typ.
Max. Min. Typ.
t
S
t
H
t
RR
t
PW
t
skew
t
r
t
f
Note:
1. Within-device skew is defined as identical transitions on similar paths through a device.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
3
Micrell, Inc.
SY10E154
SY100E154
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
USA
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.