First Sensor PIN PD Data Sheet
Part Description X100-7 SMD
International / US Order # 501401 / 01-163
Version 26-11-13
Features
• 100 mm² PIN detector
• Light blocking encapsulant
• Low dark current
• Low capacitance
• High shunt resistance
• High sensitivity
Description
Square active area PIN photodiode
with 100 mm² active area. Ceramic
carrier type LCC10 package with
light blocking black epoxy
encapsulant. Reflow solderable. Non-
hermetic.
Application
• Ionizing radiation detector
• Medical equipment
• Personal dosimeter
RoHS
2002/95/EC
Absolute maximum ratings
Symbol
T
STG
T
OP
V
max
I
PEAK
Parameter
Storage temp
Operating temp
Max reverse voltage
Peak DC current
Min
-40
-20
Max
100
70
50
10
Unit
°C
°C
V
mA
Absorption of gamma radiation (23 °C)
100,0%
Absorption probability (%)
10,0%
Schematic
Lead 3
1,0%
0,1%
1
10
100
1000
Lead 8
Gamma energy (keV)
Electro-optical characteristics @ 23 °C
Symbol
Characteristic
Active area
Active area
Energy range of
detectable radiation
Dark current
Temperature coefficient
Capacitance
Rise time
Shunt Resistance
Noise current
Breakdown voltage
Test Condition
Min
Typ
10 x 10
100
Max
Unit
mm
mm²
keV
nA
%/K
pF
pF
ns
MΩ
A/√Hz
V
Gamma radiation
V
R
= 12 V
V
R
= 12 V; change of dark current
V
R
= 0 V; f = 10 kHz
V
R
= 12 V; f = 10 kHz
V
R
= 12 V; E = 10 keV; R
L
= 50 Ω
V
R
= 10 mV
V
R
= 12 V
I
R
= 2 µA
5
1.5
13
500
80
40
6.1 E-14
80
1000
3
I
D
T
K
(I
D
)
C
t
R
500
V
BR
50
European, International Sales:
First Sensor AG
Peter-Behrens-Strasse 15
12459 Berlin
Germany
T +49 30 6399 2399
F +49 30 639923-752
sales.opto@first-sensor.com
USA:
First Sensor Inc.
5700 Corsa Avenue #105
Westlake Village
CA 91362 USA
T +1 818 706 3400
F +1 818 889 7053
sales.us@first-sensor.com
First Sensor PIN PD Data Sheet
Part Description X100-7 SMD
International / US Order # 501401 / 01-163
Version 26-11-13
Dark current (23 °C)
1,0E-07
Capacitance as fct of reverse bias (23 °C)
500
450
400
Dark current (A)
Capacitance (pF)
1,0E-08
350
300
250
200
150
100
50
1,0E-09
1,0E-10
0
10
20
30
0
0
10
20
30
40
50
Reverse bias (V)
Reverse bias (V)
Package dimension:
Small quantities: Foam pad, boxed (12 cm x 16.5 cm)
Handling:
Please refer to document "Instructions for handling and processing"
Disclaimer:
Due to our strive for continuous improvement, specifications are subject to change within our PCN policy according to JESD46C.
First Sensor AG
Peter-Behrens-Strasse 15
12459 Berlin
Germany
T +49 30 6399 2399
F +49 30 639923-752
sales.opto@first-sensor.com
European, International Sales:
USA:
First Sensor Inc.
5700 Corsa Avenue #105
Westlake Village
CA 91362 USA
T +1 818 706 3400
F +1 818 889 7053
sales.us@first-sensor.com