FVA100 — ICCNexergy
Page 1 of 3
FVA100 Series
100 W ITE Open Frame Power
Supply
• High Efficiency: Level V
• Up to 120W with Forced Air
• High Power Density 8.7/in3
• Hold-up Time >60ms at full load
• EISA and CEC Compliant
• Power Factor Correction
• Grounded Output
• Safety Approval - EN60950-1
• CEC Compliant
• Grounded Output
• Safety Approval - EN60950-1
Elpac Part
Number
FVA100012A
FVA100015A
FVA100018A
FVA100024A
Output
Voltage
12.0V
15.0V
18.0V
24.0V
Output
Current
8.3A
6.7A
5.6A
4.2A
Peak
Current
10.0A
8.0A
6.7A
5.0A
Total
Regulation
±5%
±5%
±5%
±5%
Typical
Efficiency
88%
88%
89%
89%
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Zero Load Power Consumption
Touch Leakage Current
85 - 264VAC 100 - 240VAC Nominal
47 - 63Hz
<2A rms
<37A at 230VAC cold start
>0.96
<0.5W
<125µA @ 132VAC @ 60Hz
<175µA @ 264VAC @ 60Hz
http://iccnexergy.com/elpac/ite-power-supplies/open-frame/fva100/
5/27/2011
FVA100 — ICCNexergy
Page 2 of 3
Output
Output Voltage
Total Regulation
Minimum Load
Start-Up Delay
Hold-Up Time
Ripple & Noise
Over Voltage Protection
Over Temperature Protection
Over Current Protetion
Short Circuit Protection
See Table
+/-5%
No minimum load required
<750ms
>60ms at any input voltage
<1% pk-pk **
110-135%
Active - Recoverable; plus Passive - Non Recoverable
120 - 180%
shutdown, auto-restart (hiccup mode)
General
Efficiency
MTBF
Size
Weight
Power Density
Avg Efficiency 88.6% @ 115VAC; 89.5% @ 230VAC
min. 200,000 hours demonstrated
4.50
0.66 lbs (.30 kg)
8.7W/in3 (at 120W)
Environmental
Operating Temperature 0 – 70°C (Full load to 50°C, derate linearly to 50% load at 70°C)
Storage Temperature
Relative Humidity
Cooling
Vibration
-40°C to +85°C
5-95%, non-condensing
Natural Convection (100W) or Forced Air (120W)
All units production tested to 19.6m/s2
EMC & Safety
Emissions
Immunity
FCC class B, CISPR22 class B EN61000-3-2, -3
EN61000-4-2, -3, -4, -5, -6, -8, -11
http://iccnexergy.com/elpac/ite-power-supplies/open-frame/fva100/
5/27/2011
FVA100 — ICCNexergy
Page 3 of 3
Certified by TUV to the following:
cTUVus
UL 60950-1
CAN/CSA-22.2 No.60950-1
CB per IEC60950-1
CE marked to LVD
FVA100 | ICCNEXERGY | © 2011 |
http://iccnexergy.com/elpac/ite-power-supplies/open-frame/fva100/
5/27/2011