* Consult factory on conditions for approval acceptability
* Consult factory on conditions for approval acceptability
Product
Description
• Sub-miniature bimetal thermostat
• 8-PIN DIP package configuration
• Snap-acting trip mechanism
increases operational life
Poles
SPST
Current & Voltage Rating
• 1.0A max at 48VDC
25,000 cycles
• 1.0A max at 120VAC
30,000 cycles
• 0.020A max at 5VDC
100,000 cycles (gold)
• 0.5A max at 48VDC
20,000 cycles
• 0.001A max at 5VDC
100,000 cycles (gold)
Operating Temperature
• 40°C to 130°C
(104°F to 266°F)
Approvals*
• c
Я
Uus
• VDE approved
Page
6600 Series
33
• 40°C to 130°C
(104°F to 266°F)
• c
Я
Uus
• VDE (“P” option)
6700 Series
• Sub-miniature bimetal thermostat
• TO-220 package configuration
• Snap-acting trip mechanism
increases operational life
• VDE approved “P” version
SPST
37
• 5000A, 65VDC
• 5000A, 80VDC
• 2000A, 250VAC
• 5000A, 120/240VAC (2 poles)
• 5000A, 80VDC (2 poles)
• 1000A
• C-UL recognized
• UL1077 recognized
• UL489A listed
• TUV approved
IAR Series
• 1U (1RU) hydraulic magnetic
circuit breaker
• Low-profile design
• Auxiliary switch options available
for alarm signaling
• Compact magnetic-hydraulic
circuit protector
• Aesthetically pleasing for front
panel mounting
• Toggle, rocker, push-pull and
push-to-reset actuation options
2
• 50A max at 80 VDC / 250 VAC
• 30A max, 120/240VAC
(2 poles)
42
SNAPAK®
2
• 7.5A max at 50 VDC / 250 VAC
• 30A max at 32 VDC / 120 VAC
• 25A max at 120/240 VAC
(two poles)
• 20A max at 250 VAC
(50/60 Hz, at 500AIC)
• 20A max at 65 VDC
[two poles, at 500AIC]
AP ratings
• 20A max at
50 VDC/ 240 VAC
UP ratings (1 pole only)
• 20A max at 50 VDC
• 15A max at 120 VAC
• 7.5A max at 240 VAC
• UL recognized
• CSA certified
• TUV approved
• CE compliant
• CCC approved
54
AP Series
• QPL to MIL-PRF-39019
• Sealed magnetic-hydraulic
circuit protection
• Can withstand 100G shock
repeatedly
• Ideal for use in Class 1, Div. 2
Groups A, B, C & D hazardous
locations
• Compact magnetic-hydraulic
circuit protection
• Quick-connect, screw, PC board
mount
terminals
• Auxiliary switch options
• Multi-pole options with multi or
single handle
• IEG versions meet IEC spacing
requirements for installation in
equipment that must comply
with IEC 601 and 950, and
VDE 0730, 0804 and 0805
• Multi-pole options with multi or
single handle
• Auxiliary switch options
• Mid-trip handle option
• Snap-in mounting option
• Dual frequency delay options
• LEGA is a new “low depth”
version of our standard IAG
series hydraulic magnetic
circuit breaker
3
AP ratings
• 500A, 50 VDC, 120 VAC
• 300A, 240 VAC
UP ratings
• 1000A, 50VDC, 240 VAC
• MIL-PRF-M39019
• UL recognized
(UP type only)
• FM approved
(UP type only)
70
IPA Series
4
• 30A max at 65 VDC / 240 VAC
• 20A max at 80 VDC (300 AIC)
• 25A max at 250 VAC, 50/60 Hz
• 15A max at 250 VAC, 400 Hz
• 25A max at 65 VDC / 250 VAC,
(TUV)
• 15A max at 250 VAC, 400 Hz
(TUV)
• 50A max at 80 VDC
• 50A max at 240 VAC
• 30A max at 277 VAC,
50/60 Hz
• 30A max at 250 VAC,
400 Hz
• 30A max at 125 VAC,
50/60 Hz
• 30A max at 120/240 VAC,
50/60 Hz
• 1000A
• UL 489A listed (CPA)
• UL recognized
• CUR recognized
• TUV certified
• CE compliant
• CCC approved
(pending)
• UL 489 listed (LEG)
• UL 489A listed (CEG)
• UL recognized
• CSA certified
• VDE available
• CE compliant
• CCC approved
• UL 1500 certified
• QPL to MIL-PRF-55629
82
IAG Series
6
• 5000A, 240 VAC, 50/60 Hz
• 1500A, 250 VAC, 400 Hz
• 7500A, 80 VDC (IEG)
• 5000A, 80 VDC (CEG)
• 2000A, 250 VAC, 50/60 Hz
(VDE)
• 4000A, 80 VDC (VDE)
• 5000A, 125 VAC, 50/60 Hz
(LEG)
• 5000A, 120/240 VAC,
50/60 Hz (LEG)
• 5000A, 240 VAC, 50/60 Hz
• 1500A, 250 VAC, 400 Hz
• 7500A, 80 VDC (IEG)
• 5000A, 80 VDC (CEG)
• 2000A, 250 VAC, 50/60 Hz
(VDE)
• 4000A, 80 VDC (VDE)
• 5000A, 125 VAC, 50/60 Hz
(LEG)
• 5000A, 120/240 VAC,
50/60 Hz (LEG)
• 5000A, 240 VAC, 50/60 Hz
98
LEGA Series
6
• 50A max at 80 VDC
• 50A max at 240 VAC
• 30A max at 277 VAC,
50/60 Hz
• 30A max at 250 VAC,
400 Hz
• 30A max at 125 VAC,
50/60 Hz
• 30A max at 120/240 VAC,
50/60 Hz
• 20A max at 240 VAC
• UL 489 listed (LEG)
• UL 489A listed (CEG)
• UL recognized
• CSA certified
• VDE available
• CE compliant
• CCC approved
• UL 1500 certified
• QPL to MIL-PRF-55629
122
LEJ Series
• 240 VAC hydraulic magnetic
circuit breaker
• UL489 listed
• Optional LEJA “low depth”
version
2
• UL 489
• TUV certified
132
Table of Contents
* Consult factory on conditions for approval acceptability
Page
Product
Description
• IEL versions meet IEC spacing requirements for
installation in equipment that must comply with
IEC 601 and 950 and VDE 0730, 0804 and 0805
• Multi-pole options with multi or single handle
• Auxiliary switch options
• Snap-in mounting option
• Mid-trip handle option
• Various actuator options
• Dual frequency delay options
• LEL versions meet IEC spacing requirements for
installation in equipment that must comply with
IEC 601 and 950 and VDE 0730, 0804 and 0805
• Multi-pole options with multi or single handle
• Auxiliary switch options
• Snap-in mounting option
• Mid-trip handle option
• Various actuator options
• Dual frequency delay options
• Unique, parallel current sensing design
• Compact size, high current capacity
• Auxiliary switch options
• Mid-trip handle option
Poles
6 max
Current & Voltage Rating
• 100A max at 65 VDC
• 70A max at 80 VDC
• 50A max at 250VDC
• 50A max at 300VDC
• 70A max at 240 VAC, 50/60 Hz
• 50A max at 277 VAC, 50/60 Hz
• 50A max at 277/480 VAC, 50/60 Hz
• 50A max at 250 VAC, 400 Hz
• 100A max at 80 VDC
• 50A max at 125 VAC, 50/60 Hz
• 80A max at 120/240 VAC, 50/60 Hz
• 100A max at 80 VDC (VDE)
• 50A max at 250 VAC (VDE)
Interrupting Capacity
• 5000A, 240 VAC, 50/60 Hz
• 1500A, 250 VAC, 400 Hz
• 7500A, 80 VDC
• 2000A, 240 VAC, 50/60 Hz (VDE)
• 2000A, 415 VAC, 50/60 Hz (VDE)
• 4000A, 80 VDC (VDE)
• 1200A, 277/480 VAC, 50/60 Hz
• 5000A, 250VDC
• 1000A, 300VDC
• 50000A, 80 VDC
• 5000A, 125 VAC
• 5000A, 120/240 VAC 50/60 Hz
• 2000A, 80 VDC
• 2000A, 250 VAC, 50/60 Hz (VDE)
• 10000A, 120/240VAC, 50/60 Hz
Approvals*
• UL recognized
• CSA certified
• VDE approved (IEL)
• CE compliant (IEL)
• CCC approved
• UL 1500 certified
• QPL to MIL-PRF- 55629
IAL Series
146
LEL Series
3 max
146
LELP Series
• UL 489 listed
• CSA certified
• VDE approved
• CE compliant
• CCC approved
1 max
146
IELR
Series
• 125A at 80 VDC
†
• 150A at 80 VDC
†
• 175A at 80 VDC
†
• 200A at 80 VDC
†
• 250A at 80 VDC
†
• 251A to 300A at 80 VDC
††
† Two paralleled poles
†† Three paralleled poles
• 10000A, 80 VDC
• 50000A, 65 VDC (up to 150 amps)
• 10000A, 80 VDC (> 150 amps)
• UL 489 listed
• UL 489A listed
• CSA certified
174
209
Series
• Meets IEC spacing requirements for installation
in equipment that must comply with IEC 601
and 950, and VDE 0730, 0804 and 0805
• Designed to mount on standard 35mm DIN rails
4 max
• 70A max at 80 VDC
• 70A max at 250 VAC, 50/60 Hz
• 50A max at 80 VDC (VDE)
• 50A max at 250 VAC, 50/60 Hz (VDE)
• 30A max at 415 VAC, 50/60 Hz (VDE)
• 7500A, 80 VDC
• 5000A, 250 VAC, 50/60 Hz
• 2000A, 277 VAC, 50/60 Hz
• 2000A at 250 VAC, 50/60 Hz (VDE)
• 2000A at 415 VAC, 50/60 Hz (VDE)
• 4000A at 80 VDC (VDE)
• UL recognized
• CSA certified
• VDE approved (IELR)
• CE compliant
186
JAE
Series
• Front or back connected terminal styles
• E-frame style model complies with UL 489
• 249 Power Selector Breaker system is listed as
a branch circuit breaker per UL 489
• Complies with international requirements
• 279 complies with UL 489A
6 max
• 100A max at 160 VDC
• 125A max at 125 VDC
• 77A max at 600 VAC
• 100A max at 347/600 VAC
• 100A max at 120, 240, 277, 480 VAC
• 100A max , 125 VDC, 240/415 VAC (VDE)
• 5000A
• 10000A
• 4000A (VDE)
• UL 489 listed
• UL 489A listed (279)
• UL recognized
• CSA certified
• VDE approved
• UL1500 certified
• CCC approved
• CE compliant
• UL 489 listed
• UL 489A listed
• UL recognized
• CSA certified
• VDE approved
• CCC approved
• CE compliant
204
• F-frame style complies with UL 489
• Various terminal options for design flexibility
• Reduced voltage drop through the circuit
breaker compared to other protective devices
• Auxiliary switch options
• Mid-trip handle options
6 max
UL489
• 100A to 250A at 160 VDC
• 100A to 250A at 65 VDC
• 100A to 250A at 125/250 VDC
• 100A to 250A at 240 VAC
UL489A
• 275A to 800A at 160 VDC
• 275A to 1200A at 65 VDC
• 10000A, 160 VDC
• 10000A, 125/250 VDC
• 65000A, 65 VDC
• 10000A, 240 VAC
• 18000A, 240 VAC
• 100000A, 65VDC
(UL489A up to 800A)
MDS2
Series
220
• Modular Distribution System provides
unprecedented flexibility
• “Hot Plug” modules allow for equipment
expansion without power shutdown
• Unique alarm conductors simplify signal wiring
• Modular load terminals available with front or
rear access
4 to 24
• Maximum load bus rating per position
is 100 amps, 125VDC
• See Airpax™ IEL series
• See Airpax™ IEL series
PGFM
Series
224
• GFCI sensing module designed to operate in
tandem with the LEL series circuit breaker
with a shunt voltage trip and auxiliary switch
• Manufactured by North Shore Safety, Ltd., a
leader in innovative safety products
• Automatic and manual reset configurations
• Power and fault status indicators
• Double insulated user interface
3 max
Ground Trip Current
• 4 to 6 mA
Trip Time, Combined Assembly
• ≤ 25 mS
Rated Voltage
• 120 VAC or 240 VAC, 50/60 Hz
Let-Go Voltage
• 60% of supply voltage
• See Airpax™ LEL series
• UL 943, Class A or
UL 1053 Compliant
Table of Contents
http://airpax.sensata.com