HCPL - 800J
PLC Powerline DAA IC
Data Sheet
Lead (Pb) Free
RoHS 6 fully
compliant
RoHS 6 fully compliant options available;
-xxxE denotes a lead-free product
Description
The HCPL-800J is a galvanically isolated Powerline Data
Access Arrangement IC. It provides the key features of
isolation, Tx line driver and Rx amplifier as required in a
powerline modem application.
Used together with a simple LC coupling circuit, the
HCPL-800J offers a highly integrated, cost effective
Analogue Front End (AFE) solution. Optical coupling
technology provides very high isolation mode rejection,
facilitating excellent EMI and EMC performance. Applica-
tion robustness is enhanced by the inherent properties
of opto-isolation devices, to effectively block the transfer
of damaging surge transients.
Excellent transmitter performance is achieved with the
use of a high efficiency, low distortion line driver stage.
Transmitter robustness is further enhanced with inte-
grated load detection and over-temperature protection
functions.
The HCPL-800J is designed to work with various trans-
ceiver ICs and significantly simplify the implementation
of a powerline modem.
Features
•
-60 dB Overall Tx Distortion
•
25 nV/ Typical Input Referred Noise
•
Load Detection Function
•
Under-Voltage Detection
•
Over-Temperature Shutdown
•
•
•
•
Highly Efficient Tx Line Driver
Built-in Rx Amplifier
Temperature Range: -40°C to +85°C
Regulatory Approvals (pending): UL, CSA, IEC/EN/DIN
EN 60747-5-2
•
Suitable for FCC Part 15 and EN50065-1 Compliant
Design
Applications
•
•
•
•
•
•
16
15
14
13
12
11
10
9
Filter
GND2
Filter
L
V
CC2
Connection Diagram
TX-EN
TX
Powerline
Transceiver IC
(ENDEC)
RX
STATUS
V
CC1
1
2
3
4
5
6
7
8
Tx-en
Tx-in
Rx-PD-out
Rx-Amp-in
Status
Rx-out
V
CC1
GND1
HCPL-800J
GND2
Tx-out
V
CC2
Tx-PD-out
Tx-LD-in
C
ext
Rx-in
R
ref
Automatic Meter Reading (AMR)
Powerline Modem
Home Automation/Control
Security and Surveillance
General Purpose Isolated Transceiver
Internet Appliances
GND2
N
GND1
GND2
GND2
CAUTION: It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.
Block Diagram
Tx -PD -out
13
Tx -en
1
AGC
G
T2
15
Tx -out
Tx -LD -in
12
Tx -in
2
Tx LED
Driver
Shield
Tx
TIA
V
CC1
7
Tx -en
Detection
Over -Temp
Detection
Line Driver
Control
14
V
CC2
16
GND2
GND1
8
Control IC
V
CC2
UVD
Load
Detection
11
C
ext
Status
5
Status
Detection
Rx
TIA
Shield
Status Logic
9
R
ref
Rx -out
6
G
R2
Rx LED
Driver
Line IC
Amp
10
Rx -in
4
Rx -Amp -in
3
Rx -PD -out
Package Pin Out
Pin Descriptions
Pin No.
Symbol
Tx-en
Tx-in
Rx-PD-out
Rx-Amp-in
Status
Rx-out
V
CC1
GND1
R
ref
Rx-in
C
ext
Tx-LD-in
Tx-PD-out
V
CC2
Tx-out
GND2
Description
Transmit Enable Input
Transmit Input Signal
Rx Photodetector Output
Receiver Output Amplifier Input
Signal indicating Line Condition
Receiving Signal Output
5 V Power Supply
VCC1 Power Supply Ground
Sets Line Driver biasing current, typically 24 kΩ
Receiving Signal Input from Powerline
External Capacitor
Tx Line Driver Input
Tx Photodetector Output
5 V Power Supply
Transmit Signal Output to Powerline
VCC2 Power Supply Ground
1
2
3
4
5
6
7
8
Tx -en
Tx -in
Rx -PD -out
Rx -Amp -in
Status
Rx -out
V
CC1
GND1
GND2
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Tx -out
15
V
CC2
14
Tx -PD -out
13
Tx -LD -in
12
C
ext
11
Rx -in
10
R
ref
9
2
Ordering Information
HCPL-800J are UL Recognized with 3750 Vrms for 1 minute per UL1577.
Option
Part number
HCPL-800J
RoHS Compliant
-000E
-500E
Packaging
SO-16
SO-16
Surface Mount
X
X
X
Tape & Reel
X
X
IEC/EN/DIN EN
60747-5-2
Quantity
45 per tube
850 per reel
To order, choose a part number from the part number column and combine with the desired option from the option
column to form an order entry.
Example 1:
ACPL-800J-500E to order product of SO-16 package in Tape and Reel packaging packaging with IEC/EN/DIN
EN 60747-5-2 Safety Approval in RoHS compliant..
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
Remarks: The notation ‘#XXX’ is used for existing products, while (new) products launched since 15th July 2001 and
RoHS compliant option will use ‘-XXXE‘.
Package Outline Drawings
16-Lead Surface Mount
Land Pattern Recommendation
0.018
(0.457)
16 15 14 13 12 11 10
9
0.050
(1.270)
0.458 (11.63)
TYPE NUMBER
DATE CODE
A 800J
YYWW
0.085 (2.16)
0.295 ± 0.010
(7.493 ± 0.254)
0.025 (0.64)
1
2
3
4
5
6
7
8
0.345 ± 0.010
(8.986 ± 0.254)
0.406 ± 0.10
(10.312 ± 0.254)
9°
ALL LEADS
TO BE
COPLANAR
± 0.002
0.018
(0.457)
0.138 ± 0.005
(3.505 ± 0.127)
0–8°
0.025 MIN.
0.408 ± 0.010
(10.160 ± 0.254)
0.008 ± 0.003
(0.203 ± 0.076)
STANDOFF
DIMENSIONS IN INCHES
(MILLIMETERS).
NOTES:
1. INITIAL AND CONTINUED VARIATION IN THE COLOR OF THE HCPL-800J’s WHITE MOLD COMPOUND IS NORMAL AND DOES NOT AFFECT
DEVICE PERFORMANCE OR RELIABILITY.
2. FLOATING LEAD PROTRUSION IS 0.006 (0.15) MAX.
3
Package Characteristics
All specifications and figures are at the nominal (typical) operating conditions of V
CC1
= 5 V, GND1 = 0 V, V
CC2
= 5 V,
GND2 = 0 V and T
A
= +25°C.
Parameter
Control IC - Line IC Momentary
Withstand Voltage
Resistance (Control IC - Line IC)
Capacitance (Control IC - Line IC)
Control IC to Ambient Thermal
Resistance
Line IC to Ambient Thermal
Resistance
Symbol
V
ISO
R
I-O
C
I-O
θ
IA
θ
OA
Min.
3750
Typ.
Max.
Units
V
rms
Test Conditions
RH< 50%, t = 1 min.,
T
A
= 25°C
V
I-O
= 500 Vdc
f = 1 MHz
1 oz. trace, 2-layer PCB
Still air, T
A
= 25°C
Note
1, 2, 3
3
>109
1.4
83
85
Ω
pF
°C/W
4
Notes:
1. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage
≥
4500 Vrms for 1 second (leakage
detection current limit, I
I-O
≤
5
µA).
This test is performed before the 100% production test for partial discharge (method b) shown in IEC/EN/
DIN EN 60747-5-2 Insulation Characteristics Table, if applicable.
2. The Control IC-Line IC Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as a Control IC-Line IC
continuous voltage rating. For the continuous voltage rating refer to your equipment level safety specification or IEC/EN/DIN EN 60747-5-2
Insulation Characteristics Table.
3. Device is considered as a two terminal device: pins 1 - 8 shorted together and pins 9 - 16 shorted together.
4. Maximum power dissipation in Control side and Line side IC’s needs to be limited to ensure that their respective junction temperature is less
than 125°C. The maximum permissible power dissipation is dependent on the thermal impedance and the ambient temperature. Details on
the typical thermal impedances are given in the Package Characteristics. Further details on applying this to an actual application can be found
in the Application Information section under Thermal Considerations.
Recommended PB-free IR Profile
30 seconds
250
°
C
Temperature (
°
C)
260
°
C (Peak Temperature)
217
°
C
200
°
C
150
°
C
60 sec
25
°
C
60 ~ 150 sec
90 sec
Time (sec)
60 sec
Note: Non-halide flux should be used
4
Regulatory Information
The HCPL-800J is pending for approval by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
with VIORM = 891 Vpeak.
UL
Recognized under UL 1577,
component recognition program, File E55361.
CSA
Approved under CSA
Acceptance Notice #5,
File CA 88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
(1)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
For rated mains voltage
≤
150 Vrms
For rated mains voltage
≤
300 Vrms
For rated mains voltage
≤
600 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
(2)
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a
(2)
V
IORM
x 1.5 = V
PR
, Type and Sample Test, t
m
= 60 sec,
Partial Discharge < 5 pC
Highest Allowable Over-voltage
(2)
(Transient Over-voltage tini = 10 sec)
Safety-limiting values - maximum values allowed in the event of a failure
Case Temperature
Control Side Power
(3)
Line Side Power
(3)
Insulation Resistance at T
S
, V
IO
= 500 V
Notes:
1. Isolation characteristics are guaranteed only within the safety
maximum ratings that must be ensured by protective circuits in
application. Surface mount classification is class A in accordance
with CECCOO802.
2. Refer to the optocoupler section of the Isolation and Control
Component Designer’s Catalog, under Product Safety Regulations
section, (IEC/EN/DIN EN 60747-5-2) for a detailed description of
Method a and Method b partial discharge test profiles.
3. Refer to the following figure for dependence of PS, INPUT and PS,
OUTPUT on case temperature.
1600
1400
Symbol
Characteristic
I – IV
I – III
I – II
55/100/21
2
Unit
V
IORM
V
PR
891
1670
V
PEAK
V
PEAK
V
PR
1336
V
PEAK
V
IOTM
T
S
P
S, INPUT
P
S, OUTPUT
R
S
6000
175
400
1500
>10
9
V
PEAK
°C
mW
mW
Ω
P
S, OUTPUT
P
S, INPUT
P
S
– POWER – mW
1200
1000
800
600
400
200
0
0
25
50
75 100 125 150 175 200
T
S
– CASE TEMPERATURE – °C
5