The 74LVC1GU04 is a single unbuffered inverter.
The input can be driven from either 3.3 V or 5 V devices. This feature allows the use of
this device in a mixed 3.3 V and 5 V environment.
2. Features and benefits
Wide supply voltage range from 1.65 V to 5.5 V
High noise immunity
ESD protection:
HBM JESD22-A114F exceeds 2000 V
MM JESD22-A115-A exceeds 200 V
24
mA output drive (V
CC
= 3.0 V)
CMOS low power consumption
Latch-up performance exceeds 250 mA
Input accepts voltages up to 5 V
Multiple package options
Specified from
40 C
to +85
C
and
40 C
to +125
C
3. Ordering information
Table 1.
Ordering information
Package
Temperature range
74LVC1GU04GW
74LVC1GU04GV
74LVC1GU04GM
74LVC1GU04GF
74LVC1GU04GN
74LVC1GU04GS
74LVC1GU04GX
40 C
to +125
C
40 C
to +125
C
40 C
to +125
C
40 C
to +125
C
40 C
to +125
C
40 C
to +125
C
40 C
to +125
C
Name
TSSOP5
SC-74A
XSON6
XSON6
XSON6
XSON6
X2SON5
Description
plastic thin shrink small outline package;
5 leads; body width 1.25 mm
plastic surface-mounted package; 5 leads
plastic extremely thin small outline package;
no leads; 6 terminals; body 1
1.45
0.5 mm
plastic extremely thin small outline package;
no leads; 6 terminals; body 1
1
0.5 mm
Version
SOT353-1
SOT753
SOT886
SOT891
Type number
extremely thin small outline package; no leads; SOT1115
6 terminals; body 0.9
1.0
0.35 mm
extremely thin small outline package; no leads; SOT1202
6 terminals; body 1.0
1.0
0.35 mm
X2SON5: plastic thermal enhanced extremely
thin small outline package; no leads;
5 terminals; body 0.8
0.8
0.35 mm
SOT1226
Nexperia
74LVC1GU04
Unbuffered inverter
4. Marking
Table 2.
Marking codes
Marking
[1]
VD
VU4
VD
VD
VD
VD
VD
Type number
74LVC1GU04GW
74LVC1GU04GV
74LVC1GU04GM
74LVC1GU04GF
74LVC1GU04GN
74LVC1GU04GS
74LVC1GU04GX
[1]
The pin 1 indicator is located on the lower left corner of the device, below the marking code.
5. Functional diagram
Fig 1.
Logic symbol
Fig 2.
IEC logic symbol
Fig 3.
Logic diagram
6. Pinning information
6.1 Pinning
Fig 4.
Pin configuration SOT353-1 and SOT753
Fig 5.
Pin configuration SOT886
74LVC1GU04
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 13 — 12 December 2016
2 of 20
Nexperia
74LVC1GU04
Unbuffered inverter
Fig 6.
Pin configuration SOT891, SOT1115 and
SOT1202
Fig 7.
Pin configuration SOT1226 (X2SON5)
6.2 Pin description
Table 3.
Symbol
n.c.
A
GND
Y
n.c.
V
CC
Pin description
Pin
TSSOP5, SC-74A and X2SON5
1
2
3
4
-
5
XSON6
1
2
3
4
5
6
not connected
data input
ground (0 V)
data output
not connected
supply voltage
Description
7. Functional description
Table 4.
Input (A)
L
H
[1]
H = HIGH voltage level; L = LOW voltage level.
Function table
[1]
Output (Y)
H
L
74LVC1GU04
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 13 — 12 December 2016
3 of 20
Nexperia
74LVC1GU04
Unbuffered inverter
8. Limiting values
Table 5.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
V
CC
I
IK
V
I
I
OK
V
O
I
O
I
CC
I
GND
P
tot
T
stg
[1]
[2]
[3]
Parameter
supply voltage
input clamping current
input voltage
output clamping current
output voltage
output current
supply current
ground current
total power dissipation
storage temperature
Conditions
V
I
< 0 V
[1]
Min
0.5
-
0.5
-
[1][2]
Max
+6.5
50
+6.5
50
V
CC
+ 0.5
50
+100
100
250
+150
Unit
V
mA
V
mA
V
mA
mA
mA
mW
C
V
O
> V
CC
or V
O
< 0 V
Active mode
V
O
= 0 V to V
CC
0.5
-
-
-
T
amb
=
40 C
to +125
C
[3]
-
65
The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
When V
CC
= 0 V (Power-down mode), the output voltage can be 5.5 V in normal operation.
For TSSOP5 and SC-74A packages: above 87.5
C
the value of P
tot
derates linearly with 4.0 mW/K.
For XSON6 and X2SON5 packages: above 118
C
the value of P
tot
derates linearly with 7.8 mW/K.
9. Recommended operating conditions
Table 6.
Recommended operating conditions
Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
V
CC
V
I
V
O
T
amb
t/V
supply voltage
input voltage
output voltage
ambient temperature
input transition rise and fall rate
V
CC
= 1.65 V to 2.7 V
V
CC
= 2.7 V to 5.5 V
Active mode
Conditions
Min
1.65
0
0
40
0
0
Typ
-
-
-
-
-
-
Max
5.5
5.5
V
CC
+125
20
10
Unit
V
V
V
C
ns/V
ns/V
74LVC1GU04
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 13 — 12 December 2016
4 of 20
Nexperia
74LVC1GU04
Unbuffered inverter
10. Static characteristics
Table 7.
Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
T
amb
=
40 C
to +85
C
V
IH
V
IL
V
OH
HIGH-level input voltage
LOW-level input voltage
V
CC
= 1.65 V to 5.5 V
V
CC
= 1.65 V to 5.5 V
I
O
=
100 A;
V
CC
= 1.65 V to 5.5 V
I
O
=
4
mA; V
CC
= 1.65 V
I
O
=
8
mA; V
CC
= 2.3 V
I
O
=
12
mA; V
CC
= 2.7 V
I
O
=
24
mA; V
CC
= 3.0 V
I
O
=
32
mA; V
CC
= 4.5 V
V
OL
LOW-level output voltage
V
I
= V
IH
or V
IL
I
O
= 100
A;
V
CC
= 1.65 V to 5.5 V
I
O
= 4 mA; V
CC
= 1.65 V
I
O
= 8 mA; V
CC
= 2.3 V
I
O
= 12 mA; V
CC
= 2.7 V
I
O
= 24 mA; V
CC
= 3.0 V
I
O
= 32 mA; V
CC
= 4.5 V
I
I
I
CC
C
I
V
IH
V
IL
V
OH
input leakage current
supply current
input capacitance
HIGH-level input voltage
LOW-level input voltage
V
I
= 5.5 V or GND; V
CC
= 0 V to 5.5 V
V
I
= 5.5 V or GND; I
O
= 0 A;
V
CC
= 1.65 V to 5.5 V
V
CC
= 3.3 V; V
I
= GND to V
CC
V
CC
= 1.65 V to 5.5 V
V
CC
= 1.65 V to 5.5 V
I
O
=
100 A;
V
CC
= 1.65 V to 5.5 V
I
O
=
4
mA; V
CC
= 1.65 V
I
O
=
8
mA; V
CC
= 2.3 V
I
O
=
12
mA; V
CC
= 2.7 V
I
O
=
24
mA; V
CC
= 3.0 V
I
O
=
32
mA; V
CC
= 4.5 V
-
-
-
-
-
-
-
-
-
0.8
V
CC
-
V
CC
0.1
0.95
1.7
1.9
2.0
3.4
-
-
-
-
-
-
0.1
0.1
6
-
-
-
-
-
-
-
-
0.1
0.45
0.3
0.4
0.55
0.55
1
4
-
-
V
V
V
V
V
V
A
A
pF
V
0.75
V
CC
-
V
CC
0.1
1.2
1.9
2.2
2.3
3.8
-
-
-
-
-
-
-
-
-
V
0.25
V
CC
V
-
-
-
-
-
-
V
V
V
V
V
V
Conditions
Min
Typ
[1]
Max
Unit
HIGH-level output voltage V
I
= V
IH
or V
IL
T
amb
=
40 C
to +125
C
0.2
V
CC
V
-
-
-
-
-
-
V
V
V
V
V
V
HIGH-level output voltage V
I
= V
IH
or V
IL
74LVC1GU04
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 13 — 12 December 2016