https://www.phoenixcontact.com/hq/products/1419496
Sensor/Actuator cable - SAC-8P-MS/40,0-280/FS SH SCO - 1419496
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 8-position, PUR halogen-free, black-gray RAL 7021, shielded, Plug straight M12
SPEEDCON, A-coded, on Socket straight M12 SPEEDCON, A-coded, Cable length: 40 m
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4055626168869
85444290
Made to Order (non-returnable)
1 STK
50 STK
Technical data
Dimensions
Length of cable
40 m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
Overvoltage category
Degree of pollution
2A
30 V
8
≥ 100 MΩ
A - standard
No
II
3
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1419496
Sensor/Actuator cable - SAC-8P-MS/40,0-280/FS SH SCO - 1419496
Technical data
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
HB
CuZn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Standards and Regulations
Flammability rating according to UL 94
HB
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
Wire colors
Overall twist
Shielding
Optical shield covering
External sheath, color
External cable diameter
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Ambient temperature (operation)
PUR halogen-free gray
280
LiY-FC11Y
0.25 mm²
24
32x 0.10 mm
1.15 mm ±0.05 mm
approx. 0.2 mm (Core insulation)
approx. 0.6 mm (Outer cable sheath)
Brown, white, green, yellow, gray, pink, blue, red
5 wires around filler to the core
Tinned copper braided shield
85 %
gray RAL 7001
5.90 mm
59 kg/km
PUR
PVC
Bare Cu litz wires
max. 79.9 Ω/m
300 V
1200 V
-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (cable, flexible installation)
Drawings
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1419496
Sensor/Actuator cable - SAC-8P-MS/40,0-280/FS SH SCO - 1419496
Schematic diagram
Schematic diagram
Pin assignment M12 plug, 8-pos., view plug side
Pin assignment M12 socket, 8-pos., A-coded, view female side
Cable cross section
Dimensional drawing
47,3
Ø14,8
M12
PUR halogen-free gray [280]
Plug, M12 x 1, straight, shielded
Dimensional drawing
Circuit diagram
1
44,5
Ø12
1
2
3
4
5
6
7
8
2
3
Ø14,8
M12
Ø12
4
5
6
7
8
M12 x 1 socket, straight, shielded
Contact assignment of M12 connector/socket
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com