https://www.phoenixcontact.com/hq/products/1401233
Sensor/Actuator cable - SAC-3P-10,0-160/M8FS 0,34 - 1401233
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 3-position, PUR halogen-free, Irradiated, yellow RAL 1021, free cable end, on Socket
straight M8, Cable length: 10 m
With yellow line 160
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356540537
85444290
Made to Order (non-returnable)
1 STK
50 STK
Technical data
Dimensions
Length of cable
10 m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
IP68
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
4A
60 V
3
≥ 100 MΩ
A - standard
No
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1401233
Sensor/Actuator cable - SAC-3P-10,0-160/M8FS 0,34 - 1401233
Technical data
General
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
II
3
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
HB
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Standards and Regulations
Flammability rating according to UL 94
HB
Cable
Cable type
Cable type (abbreviation)
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
Length of twist, overall twist
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Torsion force
Outer sheath, material
Material conductor insulation
Conductor material
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Special properties
PUR irradiated halogen-free yellow
160
4x 0.34 mm² (Signal line)
22
19x 0.15 mm
1.05 mm ±0.05 mm (Signal line)
brown, white, blue, black
4 wires, twisted
27 mm
yellow RAL 1021
5.2 mm ±0.2 mm
min. 15 mm
min. 30 mm
5000000
52 mm
10 m
3 m/s
360 °/m
PUR
PE
Bare Cu litz wires
≤ 57 Ω/km
320 V AC
2500 V AC (50 Hz, 5 minutes)
Silicone-free
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1401233
Sensor/Actuator cable - SAC-3P-10,0-160/M8FS 0,34 - 1401233
Technical data
Cable
Flame resistance
Halogen-free
Other resistance
Ambient temperature (operation)
DIN VDE 0472 part 804, test type B
The cable is halogen-free
hydrolysis and microbe resistant
-50 °C ... 105 °C (cable, fixed installation)
-40 °C ... 105 °C (cable, flexible installation)
Drawings
Schematic diagram
4
Cable cross section
3
1
Pin assignment M8 socket, 3-pos., view female side
PUR irradiated halogen-free yellow [160]
Dimensional drawing
Circuit diagram
33,7
1
BN
BK
BU
Ø7,5
Ø10
M8
4
3
Socket M8 x 1, straight
Contact assignment of M8 socket
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 3 / 3