电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

86082-6020

产品描述Fiber Optic Connector, 9/125um, Single Mode, Simplex
产品类别连接器   
文件大小152KB,共8页
制造商Molex
官网地址https://www.molex.com/molex/home
下载文档 详细参数 全文预览

86082-6020概述

Fiber Optic Connector, 9/125um, Single Mode, Simplex

86082-6020规格参数

参数名称属性值
是否无铅含铅
是否Rohs认证不符合
厂商名称Molex
Reach Compliance Codeunknown
ECCN代码EAR99
Is SamacsysN
连接类型SIMPLEX
连接器类型FIBER OPTIC CONNECTOR
联系完成配合NOT SPECIFIED
触点材料NOT SPECIFIED
耦合类型SNAP
DIN 符合性NO
光纤尺寸9/125um
IEC 符合性NO
插入损耗0.5 dB
MIL 符合性NO
制造商序列号86082
模式SINGLE
安装类型CABLE
选件GENERAL PURPOSE
Base Number Matches1

文档预览

下载PDF文档
FEATURES AND SPECIFICATIONS
Features and Benefits
Precision alignment pins improve insertion loss
performance
Fanouts to simplex fiber connectors require no splicing
resulting in cost reduction
MTP to HBMT and BMTP cable assemblies provide a
transition from the board to the backplane
Color coded housings ensure singlemode and multimode
assemblies are easily distinguished
Push-pull mating of MTP* for quick connections
Variety of MTP adapters facilitate multiple mounting
options for flexible board and panel layouts
*MTP is a registered trademark of US Conec Ltd.
Applications
Dense interconnect for datacommunication and
telecommunication systems
Chassis-to-chassis connections
Miniature interconnenction for optoelectronic modules
Reference Information
Connector Body Material: Polymer
Housing: UL V-0
MTP/MPO sold as terminations only
MTP*/MPO
Connectors and Adapters
MTP/MPO connectorized ribbon fiber cable assemblies provide
reliable high performance interconnects of up to 24 fibers in a
small footprint. The MTP/MPO connectors utilize the precision
molded NTT compatible ferrule which connects four to 24
fibers using bare ribbon or ruggedized ribbon cable.
Alignment between mating ferrules is accomplished using two
precision guide pins that are pre-installed into the designated
male connector.
MTP/MPO assemblies utilize a push-pull connector housing
for a quick and reliable connection. For optical device
interconnections, MTP/MPO assemblies interface on the
daughter card to Molex’s HBMT and BMTP adapters on the
backplane.
Multiple transitions between ribbon cable to individual fibers
are available to meet a variety of fiber routing requirements.
Fanouts to single fiber leads connectorized with Molex
industry standard LC, MU, FC, SC and ST connectors are
available to interconnect with the current installed base of
transmitters, receivers and patch panels.
A singlemode low loss version of the MTP/MPO connector is
achieved by using more precise MT 8-fiber ferrules and guide
pins. The superior precision of the singlemode low loss MT
ferrule yields comparable insertion loss values of the single
fiber ceramic ferrules.
MTP/MPO connectors meet IEC 1754-7 and TIA/EIA 604-5
standards.
Mating of the MTP/MPO connectors can be achieved by using
a variety of MTP/MPO adapters. For applications where EMI is
a concern, Molex has developed a series of shuttered die cast
adapters that are designed to shield and isolate EMI
emissions.
ORDERING INFORMATION
MTP Connectors
Part No.
86081-3030
86081-3020
86081-5020
86081-6020
86082-3030
86082-3020
86082-5020
86082-6020
Body
Male, Black
Male, Beige
Male, Green
Male, Yellow
Female, Black
Female, Beige
Female, Green
Female, Yellow
Mode
Multimode
Multimode
Singlemode
Singlemode
Multimode
Multimode
Singlemode
Singlemode
Insertion Loss At Test
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
Ferrule Hole Size
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
Ferrule Port
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
APC
Cable Type
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Boot
Black
Black
Black
Black
Black
Black
Black
Black
Black
Mates With
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP / BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
Yes
Yes
Yes
Yes
MPO Connectors
Part No.
86083-3093
86083-3090
86083-5090
86083-6094
86084-3093
86084-3090
86084-5090
86084-6094
86083-3095
86083-3092
86083-3096
86083-6099
86084-3095
86084-3092
86084-5096
86084-6099
86083-3094
86083-3091
86083-5002
86083-6098
86084-3094
86084-3091
86084-5097
86084-6098
Body
Male, Black
Male, Beige
Male, Green
Male, Yellow
Female, Black
Female, Beige
Female, Green
Female, Yellow
Male, Black
Male, Beige
Male, Green
Male, Yellow
Female, Black
Female, Beige
Female, Green
Female, Yellow
Male, Black
Male, Beige
Male, Green
Male, Yellow
Female, Black
Female, Beige
Female, Green
Female, Yellow
Mode
Multimode
Multimode
Singlemode
Singlemode
Multimode
Multimode
Singlemode
Singlemode
Multimode
Multimode
Multimode
Multimode
Multimode
Multimode
Singlemode
Singlemode
Multimode
Multimode
Multimode
Multimode
Multimode
Multimode
Singlemode
Singlemode
Insertion Loss At Test
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
Ferrule Hole Size
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
Ferrule Port
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
APC
Cable Type
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Boot
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Mates With
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP / BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Molex reserves the right to make any changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application.
1
MOLEX FIBER OPTICS DIVISION
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A1-FIBER or (630) 512-8787 Web: www.molex.com/fiber
基于PNX1500的嵌入多媒体平台
随着片上系统设计技术的发展,嵌入式技术在IT界扮演着越来越多的重要的角色。多媒体应用是嵌入式系统的一个重要方面,本文介绍了一种基于飞利浦PNX1500DSP的多媒体嵌入式系统的硬件设计以及底层 ......
呱呱 嵌入式系统
台达VFD-P 11KW的"CFF"故障,还是没搞定!
请教台达VFD-P系列11KW的"CFF"故障    一台达VFD-P系列11KW变频器,驱动一惯量较大的负载(外接有BRAKE单元),以前正常,现在出现"CFF"故障.    "CFF"的意义是:“变频器有异常输出现象.输出接 ......
eeleader 工业自动化与控制
【allegro】如何把一整张图1分为2的变成两个信号!
作者:心影 我们平常一般会进行整板铺地铜,电源铜的动作,但是如果原理突然改变了,需要把电源层一个电源变成两个电源,通常的做法是把铜修改小了,重新铺一块,但是还有一种方法,大家 ......
ohahaha PCB设计
为什么STR710的PLL1有输入限制?如果超过了有什么影响吗?
我的有源晶振是16MHz的,2分频后,输入PLL1,然后倍频16倍,再2分频,输出64MHz给MCLK,相关实验都做过了,没有什么问题,包括高低温的实验。今天再看710的ElectricalCharacteristics,才 ......
koko1314 stm32/stm8
关于Quartus中仿真的问题
是这样的,写了verilog的一个小程序,编译成功了,然后创建bdf文件以后,再编译,就出错。 报错是: Error: Can't compile duplicate declarations of entity "sig" into library "work" ......
zany.peng 嵌入式系统
使用AM5728 EVM制作并下载6678的程序
本步骤可以把8个.out文件通过工具合成一个用于网络发送的文件,并发送到6678EVM上运行。 1、AM5728EVM控制台执行EMACboot_8core.sh脚本,这个脚本可以把8个.out文件合成一个用于网络发送 ......
Jacktang DSP 与 ARM 处理器

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1218  1148  2168  2795  1839  25  24  44  57  38 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved