Tripp Lite's line-interactive SM5000RT3UTAA UPS System is compliant with the Federal Trade Agreements Act
(TAA) for GSA Schedule purchases. This UPS protects server, networking or telecommunications equipment
from blackouts, voltage fluctuations and surges in a compact tower/rackmount housing. In rack configuration, the
power module and battery pack occupy only 3 rack spaces (3U) each. Large capacity 5000VA/4000W power
module converts raw 208V AC input to fully regulated dual output 208/120 voltage for simultaneous protection of
both high- and low-voltage equipment loads. True sine wave output at all times offers guaranteed compatibility
with all equipment types. Includes 14 outlets, 8 of which can be individually reset via software interface to
Package Includes
SM5000RT3UTAA UPS System
BP48V60RT3U battery pack
USB, DB9 and EPO Cabling
Mounting hardware
Instruction manual with warranty
information
selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical equipment. Battery support can be extended
indefinitely with additional external 3U rackmount battery packs. Network management interfaces support communications via USB, RS-232 and optional slot
for network management card options.
Features
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Large 5000VA/4000W output capacity with full-time sine wave output offers guaranteed compatibility with all equipment types
High power density 5kVA power module and battery pack occupy only 3 rack spaces (3U) each (UPS and battery pack require 6U total installed)
38 min. half load runtime, expandable with multiple external battery packs (part# BP48V60RT3U)
Line-interactive voltage regulation corrects severe brownouts and overvoltages without using battery power
Dual voltage output is simultaneously compatible with both 208V and 120V equipment
14 total outlets (120V: 10 x 5-15R, 2 x 5-20R/208V: 1 x L6-30R, 1 x L14-30R)
Diagnostic LEDs provide visual indication of 17 separate performance conditions
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from
www.tripplite.com/poweralert
4 built-in communications ports (2 x DB9, 2 x USB) for remote monitoring and unattended shutdown
Compatible with Tripp Lite UPS management card options
WEBCARDLX
and
SNMPWEBCARD
1/5
8 customized load management receptacles can be individually powered off and back on again via software interface to reboot remote equipment or
perform "load shedding" of less critical loads to extend battery runtime for the most critical equipment
Emergency Power Off (EPO) interface for emergency shutoff in large facilities
Hot-swappable/user replaceable batteries allow on-site battery replacement through the front panel without powering off connected equipment or
removing the UPS from the rack
UPS battery set ships fully assembled and ready for connection to the power module, no time consuming, connection of individual internal batteries by
user is necessary
$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
NAFTA compliant
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Output Capacity Details
Power Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
Load Management Receptacles
Output Circuit Breakers
Output AC Waveform (AC Mode)
Output AC Waveform (Battery Mode)
5000
5
4000
4
Output increases to 4800W maximum when user supplied 50A input plug or hardwire input is used
0.8
110V; 115V; 120V; 208V
208/120V nominal output in battery mode
60 Hz
208 & 120V (-10%, +20%)
+/- 5%
(10) 5-15R; (2) 5-15/20R; (1) L14-30R; (1) L6-30R
Eight switchable single-outlet 5-15R load banks
15A branch rated (x3) - 2 breakers support 5 5-15R outlets each, one breaker supports 2 5-20R outlets, L6-30R and
L14-30R outlets are unbreakered
Sine wave
Pure Sine wave
INPUT
Nominal Input Voltage(s) Supported
UPS Input Connection Type
Input Circuit Breakers
UPS Input Cord Length (ft.)
208V AC
L6-30P
30A double-pole
10
2/5
UPS Input Cord Length (m)
Recommended Electrical Service
Input Cord Length (ft.)
Input Cord Length (m)
Input Phase
3.0
30A 208V
10
3.05
Single-Phase
BATTERY
Full Load Runtime (min.)
Half Load Runtime (min.)
Expandable Battery Runtime
External Battery Pack Compatibility
DC System Voltage (VDC)
Battery Recharge Rate (Included
Batteries)
Battery Replacement Description
Expandable Runtime
16 min. (4000w)
38 min. (2000w)
Extended runtime supported via optional external battery packs
BP48V24-2U
(limit 1);
BP48V60RT-3U(multi-pack
compatible);
BP48V27-2US(multi-pack
compatible)
48
3 hours
Hot-swappable, user replaceable batteries
Yes
VOLTAGE REGULATION
Voltage Regulation Description
Overvoltage Correction
Undervoltage Correction
Severe Undervoltage Correction
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 282
Input voltages between 240V and 282 are reduced by 12%
Input voltages between 180V and 199 are boosted by 12%
Input voltages between 151V and 179 are boosted by 24%
USER INTERFACE, ALERTS & CONTROLS
Switches
Alarm Cancel Operation
Audible Alarm
LED Indicators
2 Switches control off/on power status and alarm-cancel/self-test operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Audible alarm indicates power-failure, overload and low-battery conditions
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
UPS AC Suppression Response
Time
EMI / RFI AC Noise Suppression
1020
Instantaneous
Yes
PHYSICAL
3/5
Installation Form Factors Supported
with Included Accessories
Installation Form Factors Supported
with Optional Accessories
Optional Mounting Accessory Notes
Primary Form Factor
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
Rack Height (U Spaces)
Minimum Required Rack Depth
(inches)
Minimum Required Rack Depth (cm)
UPS Power Module Weight (kg)
UPS Dimensions Details
Included Battery Pack Dimensions
(hwd / in.)
Included Battery Pack Weight (lbs.)
Included Battery Pack Weight (kg)
UPS Shipping Dimensions (hwd / in.)
UPS Shipping Dimensions (hwd /
cm)
Shipping Weight (lbs.)
Shipping Weight (kg)
Cooling Method
UPS Housing Material
Minimum Required Rack Depth (mm)
Primary UPS Height (mm)
Primary UPS Width (mm)
Primary UPS Depth (mm)
Shipping Height (mm)
Shipping Width (mm)
Shipping Depth (mm)
4 post 19 inch rackmount
2 post rackmount(2POSTRMKITHD ); Tower(2-9USTAND)
2 sets of
2POSTRMKITHD
required for 2 post rackmount installation of separate power module and battery pack
Rackmount
5.2 x 17.5 x 22.5
13.21 x 44.45 x 57.15
6
29.5
74.93
0
Includes 3U UPS/power module and 3U external battery pack
5.2 x 17.5 x 22.8
135
61.23
24.5 x 35 x 24
62.2 x 88.9 x 61
321.6
146
Fans
Steel
749
132
444
572
622
889
610
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
4/5
Relative Humidity
Battery Mode BTU / Hr. (Full Load)
AC Mode Efficiency Rating (100%
Load)
0 to 95%, non-condensing
1518
94%
COMMUNICATIONS
Communications Interface
Network Management Cards
Network Monitoring Port Description
PowerAlert Software
Communications Cable
WatchDog Compatibility
Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB
SNMPWEBCARD; WEBCARDLX
Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact
closure port (4 total)
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at
http://www.tripplite.com/poweralert
USB and DB9 cabling included
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
2-4 milliseconds
151
282
SPECIAL FEATURES
Grounding Lug
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS Features
Back panel grounding lug
Cold-start operation supported
Hot swappable batteries
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A
not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: