SPECIFICATION CONTROL DRAWING
TITLE
82A6013
Date
WIRE, RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE-INSULATED,
NORMAL WEIGHT, GENERAL PURPOSE, 600 VOLT
8-4-10
Revision
D
This specification sheet forms a part of the latest issue of Raychem Specification 80.
CONDUCTOR - NICKEL-COATED COPPER
JACKET - RADIATION-CROSSLINKED,
MODIFIED FLEXIBLE ETFE
COLOR - WHITE
PRIMARY INSULATION - RADIATION-CROSSLINKED,
MODIFIED FLEXIBLE ETFE
COLOR - LIGHT GREEN
BRAID - NOMEX BRAID TREATED
TO PREVENT FRAYING
COLOR - WHITE
TABLE I. CONSTRUCTION DETAILS
PART NUMBER
1/
WIRE
SIZE
(AWG)
8
6
4
2
CONDUCTOR
STRANDING
(number x AWG)
665 x 36
1045 x 36
1665 x 36
1665 x 34
DIAMETER OF
STRANDED
CONDUCTOR
(in.)
MINIMUM
82A6013-8
82A6013-6
82A6013-4
82A6013-2
.157
.192
.265
.325
MAXIMUM
.173
.208
.285
.345
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
.714
.490
.326
.204
DIAMETER
(in.)
.245 ± .008
.292 ± .010
.374 ± .010
.447 ± .016
MAXIMUM
WEIGHT
(lbs/1000 ft.)
81.2
123.
196.
291.
TABLE II. PERFORMANCE DETAILS
BEND TESTING
PART NUMBER
1/
82A6013-8
82A6013-6
82A6013-4
82A6013-2
MANDREL DIAMETER
(inch) (± 3%)
CROSSLINKING PROOF TEST
3.00
4.00
5.00
6.00
WEIGHT
(lb) (± 3%)
CROSSLINKING PROOF TEST
4.00
4.00
4.00
6.00
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/
COLORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART
NUMBER. AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
The TE logo, Tyco Electronics and Raychem are trademarks.
NOMEX is a registered trademark of E.I. du Pont de Nemours and Company
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
Page 1 of 2
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2010 Tyco Electronics Corporation. All rights reserved.
SPECIFICATION CONTROL DRAWING
Page 2 of 2
Revision
D
SCD Number
82A6013
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
CONCENTRICITY: 70% (minimum)
CROSSLINKING PROOF TEST: 300 ± 3°C for 7 hours
INSULATION ELONGATION AND TENSILE STRENGTH:
Elongation, 125% (minimum)
Tensile Strength, 3000 lbf/in² (minimum)
INSULATION FLAWS:
Primary Insulation,
Spark Test, 1.5 kV (rms) at 3 kHz
Impulse Dielectric Test, 6.0 kV (peak)
Finished Wire,
Spark Test, 3.0 kV (rms) at 3 kHz
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS:
AWG 8-4: .008 in. (minimum) for primary insulation
.012 in. (minimum) for outer jacket
AWG 2: .010 in. (minimum) for primary insulation
.015 in. (minimum) for outer jacket
SECANT MODULUS: (Test per ASTM D 882)
4.0 x 10
4
lbf/in
2
(maximum), 2% strain, 2 inch jaw separation, 0.2 inch/minute
SHRINKAGE: 200 ± 3°C for 6 hours, 0.25 in. (maximum) in 12 inches
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz
PRODUCT IDENTIFICATION: Braid shall be marked in a contrasting color at
12 inch (nominal) intervals as follows: “ 82A6013-AWG 06090 “
1/
See footer section on page 1