M I C
of Crystek Corporation
ROWAVE
A Division
•
SAW Band Pass Filter
•
50
Ω
SMA Connectors
•
Test Equipment
•
Lab Use
•
Input Power: +10 dBm
•
Operating Temperature: -40°C to 85°C
•
Storage Temperature: -40°C to 85°C
Crystek’s line of SAW Band Pass Filters are designed in a rugged SMA
housing. This filter line has excellent out-of-band rejection.
Designed for Test Equipment and General Lab Use.
Product Control:
Crystek Part Number:
Revision Level:
CBPFS-0915
F
Release Date:
Responsible:
08-Feb-2016
K. Piotrowicz
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
Page 1 of 4
M I C
of Crystek Corporation
ROWAVE
A Division
PERFORMANCE SPECIFICATION
Center Frequency:
Pass Bandwidth:
Insertion Loss:
Amplitude Ripple:
Attenuation:
Attenuation:
Attenuation:
Attenuation:
Attenuation:
VSWR:
Impedance:
Operating Temperature Range:
Storage Temperature Range:
-40
-40
DC – 800 MHz
800 – 880 MHz
960 – 1080 MHz
1080 – 1500 MHz
1500 – 3000 MHz
MIN
TYP
915
26
2.2
0.6
63
48
39
65
28
1.6
50
+85
+85
°C
°C
2.3
MAX
UNITS
MHz
MHz
dB
dB
dB
dB
dB
dB
dB
Schematic
In/Out
50
Ω
In/Out
50
Ω
1.312
(33.34)
0.612
(15.54)
I/O
I/O
0.435
(11.05)
SMA
Male
SMA
Female
Rev F
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
Page 2 of 4
M I C
of Crystek Corporation
ROWAVE
A Division
Typical Frequency Characteristics [close in]
0
5
10
15
20
1
2
3
Markers
1: 900.000 MHz
2.318 dB
2: 915.000 MHz
2.076 dB
3: 930.000 MHz
2.616 dB
Loss (dB)
25
30
35
40
45
50
55
750
800
850
900
950
1000
1050
Frequency (MHz)
Typical Frequency Characteristics [full span]
0
10
20
30
Loss (dB)
40
50
60
1
2
3
Markers
1: 495.250 MHz
58.176 dB
2: 1590.141 MHz
35.639 dB
3: 2115.088 MHz
33.824 dB
70
80
90
100
0
500
1000
1500
2000
2500
3000
Frequency (MHz)
Rev F
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
Page 3 of 4
M I C
of Crystek Corporation
ROWAVE
A Division
Male Side Return Loss
0
5
10
Loss (dB)
15
20
25
30
35
750
800
850
900
950
1000
1050
Frequency (MHz)
Female Side Return Loss
5
15
Loss (dB)
25
35
45
55
65
750
800
850
900
950
1000
1050
Frequency (MHz)
Rev F
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
Page 4 of 4