https://www.phoenixcontact.com/us/products/2859741
Lightning/surge arrester combination type 1+2 - FLT-CP-1C-350 - 2859741
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters.
Arresters coordinated following the AEC principle, for 1-phase power supply networks with PE and N (L1, PEN)
installed in one cable.
Product Features
■
■
■
■
■
Plugs can be checked with CHECKMASTER
High continuous voltage of 350 V AC for 230/400 V AC networks with high voltage fluctuations
With floating remote indication contact
Optical, mechanical status indication for the individual arresters
Thermal disconnect device for each individual plug
Key Commercial Data
Packing unit
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
1 pc
356.4 g
85369010
Germany
Technical data
Environmental Product Compliance
REACh SVHC
UV -328 25973-55-1
Dimensions
Height
Width
Depth
Horizontal pitch
95 mm
35.6 mm
71.5 mm
2 Div.
Ambient conditions
04/27/2016 Page 1 / 8
https://www.phoenixcontact.com/us/products/2859741
Lightning/surge arrester combination type 1+2 - FLT-CP-1C-350 - 2859741
Technical data
Ambient conditions
Degree of protection
Ambient temperature (operation)
Ambient temperature (storage/transport)
Altitude
Permissible humidity (operation)
Shock (operation)
Vibration (operation)
IP20 (only when all terminal points are used)
-40 °C ... 80 °C
-40 °C ... 80 °C
≤ 2000 m (amsl (above mean sea level))
5 % ... 95 %
25g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
5g (5 - 500 Hz/2.5 h/X, Y, Z)
General
Standards/specifications
IEC test classification
EN type
IEC power supply system
Number of ports
SPD design
Mode of protection
Mounting type
Color
Housing material
Degree of pollution
Flammability rating according to UL 94
Type
Number of positions
Surge protection fault message
IEC 61643-11 2011
EN 61643-11 2012
I + II
T1 + T2
T1 + T2
TN-C
TT
One
Combination type
L-PEN
DIN rail: 35 mm
gray/blue
black
PBT
2
V-0
DIN rail module, two-section, divisible
1
Optical, remote indicator contact
Protective circuit
Nominal voltage U
N
Nominal frequency f
N
Maximum continuous voltage U
C
Rated load current I
L
Nominal discharge current I
n
(8/20) µs
Impulse discharge current (10/350)½µs, charge
Impulse discharge current (10/350)½µs, specific energy
240 V AC (TN-C)
240 V AC (TT)
50 Hz (60 Hz)
350 V AC
125 A (< 55 °C)
25 kA
12.5 As
160 kJ/Ω
04/27/2016 Page 2 / 8
https://www.phoenixcontact.com/us/products/2859741
Lightning/surge arrester combination type 1+2 - FLT-CP-1C-350 - 2859741
Technical data
Protective circuit
Impulse discharge current (10/350)½µs, peak value l
imp
Follow current interrupt rating I
fi
Short-circuit current rating I
SCCR
Voltage protection level U
p
Residual voltage U
res
25 kA
25 kA (264 V AC)
3 kA (350 V AC)
25 kA (264 V AC)
3 kA (350 V AC)
≤ 1.5 kV
≤ 1.5 kV (at I
n
)
≤ 1.2 kV (at 10 kA)
≤ 1 kV (at 5 kA)
≤ 0.9 kV (at 3 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs
TOV behavior at U
T
Response time t
A
Max. backup fuse with branch wiring
Max. backup fuse with V-type through wiring
≤ 1.5 kV
415 V AC (5 s / withstand mode)
457 V AC (120 min / safe failure mode)
≤ 25 ns
315 A (gG)
125 A (gG)
Indicator/remote signaling
Connection name
Switching function
Operating voltage
Operating current
Connection method
Screw thread
Tightening torque
Stripping length
Conductor cross section flexible min.
Conductor cross section flexible max.
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG
Remote fault indicator contact
PDT contact
12 V AC ... 250 V AC
125 V DC (200 mA DC)
10 mA AC ... 1 A
1 A (30 V DC)
Plug-in/screw connection via COMBICON
M2
0.25 Nm
7 mm
0.14 mm²
1.5 mm²
0.14 mm²
1.5 mm²
28 ... 16
Connection data
Connection method
Conductor cross section flexible min.
Conductor cross section flexible max.
Screw terminal blocks
2.5 mm²
25 mm²
04/27/2016 Page 3 / 8
https://www.phoenixcontact.com/us/products/2859741
Lightning/surge arrester combination type 1+2 - FLT-CP-1C-350 - 2859741
Technical data
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG
Screw thread
Tightening torque
Stripping length
2.5 mm²
35 mm²
13 ... 2
M5
4.5 Nm
18 mm
UL specifications
SPD Type
Maximum continuous operating voltage MCOV (L-G)
Nom. voltage
Mode of protection
Power distribution system
Nominal frequency
Measured limiting voltage MLV (L-G)
Nominal discharge current I
n
(L-G)
Follow current (L-G)
4CA
264 V AC
240 V AC
L-G
1S
50/60 Hz
1340 V
20 kA
10 kA (264 V AC)
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
27140201
27130801
27130801
27130801
27130808
27130808
27130808
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC001457
EC001457
EC001457
EC001457
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
30212010
39121610
04/27/2016 Page 4 / 8
https://www.phoenixcontact.com/us/products/2859741
Lightning/surge arrester combination type 1+2 - FLT-CP-1C-350 - 2859741
Classifications
UNSPSC
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
39121610
39121610
39121620
Approvals
Approvals
Approvals
UL Recognized / KEMA-KEUR / cUL Recognized / CCA / IECEE CB Scheme / EAC / EAC / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
UL Recognized
KEMA-KEUR
cUL Recognized
CCA
IECEE CB Scheme
EAC
04/27/2016 Page 5 / 8