FEATURES
Small size
-
High voltage
-
General purpose
APPLICATIONS
Operating Temperature
Range
Capacitance Tolerance
WVDC
Surge
Voltage
SVDC
WVDC
Dissipation
Tan
δ
Factor
Leakage Current
Low
temperature
Stability
Impedance
Ratio
(120 Hz
)
Bypass
–
Coupling
–
Filter
–
De-coupling
-55°C to +105°C (6.3 to 100 WVDC), -40°C to +105°C (160 to 400 WVDC)
-25°C to +85°C (450 WVDC)
+20% at 120 Hz, 20°C
6.3
7.9
10
13
16
20
25
32
35
44
50
63
63
79
100
125
160
200
250
350
400
450
500
450
.2
200
250
300
400
450
6.3
10
16
25
35
50
63
100
160
200
250
350
400
.24
.2
.17
.15
.12
.1
.1
.08
.15
.15
.15
.2
.2
Add .02 for every 1000uF above 1000uF
160 to 450 WVDC
6.3 to 100 WVDC
1 Minutes
2 Minutes
2 Minutes
.03CV or 4uA,
.01CV or 3uA,
.03CV+40uA
Whichever is greater
Whichever is greater
6.3
10
16
25
35
50
63
100
160
200
250
350
400
4
5
3
10
2
8
2
6
2
4
2
3
2
3
2
3
3
3
3
4
3
4
6
10
6
10
WVDC
-25°C to
+20°C
-40°C to
+20°C
450
15
-
Load Life
Shelf Life
Ripple Current
Multipliers
2000 hours at 105°C with rated WVDC and ripple current applied
Capacitance Change
<20% of initial measured value
Dissipation Factor
<150% of maximum specified value
Leakage Current
>100% of maximum specified value
1000 hours at 105°C with no voltage applied
Capacitance Change
<20% initial measured value
Dissipation Factor
<200% of maximum specified value
Leakage Current
>100% of maximum specified value
Frequency (Hz)
Temperature (°C)
WVDC
50
120
1k
10k
+105
+85
+70
+60
6.3 to 25V
.85
1.0
1.10
1.20
1.0
1.4
1.4
1.75
35 to 100V
.8
1.0
1.15
1.25
1.0
1.4
1.4
1.75
160 to 250V
.75
1.0
1.25
1.40
1.0
1.4
1.4
1.75
350 to 450V
.7
1.0
1.30
1.80
1.0
1.4
1.4
1.75
D
5
6.3
S
2.0
2.5
d
0.5
0.5
L
1
=L+1.5mm Max.
D
1
=D+0.5mm Max.
S
1
=S+0.5 mm
8
3.5
0.6
10
5.0
0.6
12.5
5.0
0.6
16
7.5
0.8
18
7.5
0.8
mm