Data Sheet
Coaxial Cable Connector
21_716-50-12-60/033_-
Description
Straight cable jack
Interface standards
IEC 61169-4_CECC 22190_DIN 47223_VG 95250
Technical Data
Electrical Data
Impedance
Interface frequency max.
Frequency range
Return loss
50 Ω
7.5 GHz
DC to 2.7 GHz
32 dB
2.7 to 3.7 GHz
30 dB
Mechanical Data
Centre contact
Outer contact
plugged
clamped
Environmental Data
Operating temperature
2011/65/EU, RoHS
-40 °C to 85 °C
compliant
Material Data
Piece Parts
Centre contact
Outer contact
Body
Insulator
Coupling nut
Gasket
Material
Bronze
Brass
Brass
PFA / PTFE
Brass
NR (Natural Rubber)
SUCOPLATE (R) Plating
Surface Plating
Silver Plating
SUCOPLATE (R) Plating
SUCOPLATE (R) Plating
Related Documents
Outline drawing
Assembly instruction
DOU-00318552
DOC-0000799919
Ordering Information
Single package
21_716-50-12-60/033_-E
Additional Information
Suitable cables
SUCOFEED_1/2_PW, SUCOFEED_1/2, SUCOFEED_1/2_FR, SUCOFEED_1/2_LW
Remarks
Other suitable cables: RFS CELLFLEX LCF12-50J, LCF12-50JFN, ICA12-50JPLW, ICA12-50JPLLW, ICA12-50JPL / ANDREW/
COMMSCOPE LDF4-50A / Assembly instructions: Foam-DOC-0000799919, Plenum-DOC-0000736630 / Note: Use blade unit
74_Z-0-12-21, 85068959 (colour green)
Document: DOC-0000751387 I / PDO D / date of publication: 04.10.2018 08:25:37 / uncontrolled copy
Page 1/2
Data Sheet
Coaxial Cable Connector
21_716-50-12-60/033_-
HUBER+SUHNER is certified according to ISO 9001, ISO 14001, AS/EN9100, ISO/TS 16949 and IRIS.
Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind.
www.hubersuhner.com
Document: DOC-0000751387 I / PDO D / date of publication: 04.10.2018 08:25:37 / uncontrolled copy
Page 2/2