电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

FLUKE-700PA5

产品描述Calibration Equipment PRESSURE MODULE 0-30 PSIA
产品类别热门应用    测试测量   
文件大小43KB,共2页
制造商Fluke
官网地址https://www.fluke.com
下载文档 详细参数 选型对比 全文预览

FLUKE-700PA5在线购买

供应商 器件名称 价格 最低购买 库存  
FLUKE-700PA5 - - 点击查看 点击购买

FLUKE-700PA5概述

Calibration Equipment PRESSURE MODULE 0-30 PSIA

FLUKE-700PA5规格参数

参数名称属性值
产品种类
Product Category
Calibration Equipment
制造商
Manufacturer
Fluke
RoHSDetails
Equipment TypePressure Modules
Measured ComponentsPressure
Accessory TypeAbsolute Pressure Module
Description/FunctionModule has one fitting and measures pressure with respect to an absolute vacuum
Display TypeNone
Pressure Range0 psi to 30 psi
工厂包装数量
Factory Pack Quantity
1

文档预览

下载PDF文档
Certifications
P
Conforms to European Standard EN61010-1, EN61326.
®
Limited Warranty
Each Fluke product is warranted to be free from defects in material and
workmanship under normal use and service. The warranty period is one year
and begins on the date of shipment. Parts, product repairs and services are
warranted for 90 days. This warranty extends only to the original buyer or end
user customer of a Fluke authorized reseller, and does not apply to fuses,
disposable batteries or to any product which, in Fluke’s opinion, has been
misused, altered, neglected or damaged by accident or abnormal conditions of
operation or handling. Fluke warrants that software will operate substantially in
accordance with its functional specifications for 90 days and that it has been
properly recorded on nondefective media. Fluke does not warrant that software
will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused
products to end user customers only but have no authority to extend a greater or
different warranty on behalf of Fluke. Warranty support is available if product is
purchased through a Fluke authorized sales outlet or Buyer has paid the
applicable international price. Fluke reserves the right to invoice Buyer for
importation costs of repair/replacement parts when product purchased in one
country is submitted for repair in another country.
Fluke’s warranty obligation is limited, at Fluke’s option, to refund of the purchase
price, free of charge repair, or replacement of a defective product which is
returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center
or send the product, with a description of the difficulty, postage and insurance
prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke
assumes no risk for damage in transit. Following warranty repair, the product
will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke
determines that the failure was caused by misuse, alteration, accident or
abnormal condition of operation or handling, Fluke will provide an estimate of
repair costs and obtain authorization before commencing the work.
Following repair, the product will be returned to the Buyer transportation prepaid
and the Buyer will be billed for the repair and return transportation charges (FOB
Shipping Point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING
FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT,
RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied
warranty, or exclusion or limitation of incidental or consequential damages, the
limitations and exclusions of this warranty may not apply to every buyer. If any
provision of this Warranty is held invalid or unenforceable by a court of
competent jurisdiction, such holding will not affect the validity or enforceability of
any other provision.
700PAx Series Absolute
Pressure Modules
Instruction Sheet
Introduction
Fluke Models 700PAx Series Pressure Modules allow you to
measure absolute pressure with the Fluke 740 Series
Documenting Process Calibrators. The modules have one
fitting and measure pressure with respect to an absolute
vacuum.
Read this sheet before you use the pressure module. This
sheet contains specifications and information about how to
avoid damaging the pressure module. This instruction sheet
assumes that you know how to use the 740 Series
Documenting Process Calibrator. (Refer to the Users Manual
if necessary.)
Note
These modules are not specified for use with a
Model 701 or 702 Calibrator.
The pressure module measures pressure using an internal
microprocessor. It receives operating power from and sends
digital information to the calibrator.
Box Contents
Pressure module, one 1/4 NPT to 1/4 ISO metric adapter,
strap, and instruction sheet.
Protecting Yourself from Pressure Releases
To avoid a violent release of pressure in a pressurized
system, shut off the isolation valve and slowly bleed off the
pressure before you attach or remove the pressure module
from the pressure line.
In Case of Difficulty
For service or calibration, call your nearest authorized Fluke
Service Center. To locate an authorized service center, visit
us on the World Wide Web: www.fluke.com or call Fluke
using any of the phone numbers listed below.
For application or operation assistance or information on
Fluke products, call
:
USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-678-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Fluke Corporation
Fluke Europe B.V.
P.O. Box 9090
P.O. Box 1186
Everett, WA 98206-9090 5602 B.D. Eindhoven
USA
The Netherlands
Avoiding Overpressure Damage
Applying pressure in excess of the BURST PRESSURE
specified on the pressure module can destroy the pressure
module. Burst pressure is atmosphere plus 3X full scale in
absolute units.
Avoiding Mechanical Damage
To avoid damaging the pressure module, never apply more
than 10 ft.-lb. of torque between the pressure module fitting
and the body of the module. Always apply appropriate torque
between the pressure module fitting and connecting fittings
or adapters. Figure 1 shows the correct and incorrect ways
to use a wrench when applying torque to the pressure
module fitting.
PN 603255
October 1996 Rev.3, 11/01
1996-2001 Fluke Corporation. All rights reserved. Printed in U.S.A.

FLUKE-700PA5相似产品对比

FLUKE-700PA5 FLUKE-700PA4EX FLUKE-700PA4 FLUKE-700PA6 FLUKE-700PA3
描述 Calibration Equipment PRESSURE MODULE 0-30 PSIA Calibration Equipment I.S. PRESSURE MODULE 0-15 PSIA Calibration Equipment PRESSURE MODULE 0-1 0-15PSIA Calibration Equipment PRESSURE MODULE 0-100 PSIA Calibration Equipment PRESSURE MODULE 0-5 0-5PSIA
产品种类
Product Category
Calibration Equipment Calibration Equipment Calibration Equipment Calibration Equipment Calibration Equipment
制造商
Manufacturer
Fluke Fluke Fluke Fluke Fluke
RoHS Details Details Details Details Details
Equipment Type Pressure Modules Pressure Modules Pressure Modules Pressure Modules Pressure Modules
Measured Components Pressure Pressure Pressure Pressure Pressure
Accessory Type Absolute Pressure Module Absolute Pressure Module Absolute Pressure Module Absolute Pressure Module Absolute Pressure Module
Description/Function Module has one fitting and measures pressure with respect to an absolute vacuum Module has one fitting and measures pressure with respect to an absolute vacuum Module has one fitting and measures pressure with respect to an absolute vacuum Module has one fitting and measures pressure with respect to an absolute vacuum Module has one fitting and measures pressure with respect to an absolute vacuum
Display Type None None None None None
Pressure Range 0 psi to 30 psi 0 psi to 15 psi 0 psi to 15 psi 0 psi to 100 psi 0 psi to 5 psi
工厂包装数量
Factory Pack Quantity
1 1 1 1 1
EEWORLD大学堂----机器人学
机器人学:https://training.eeworld.com.cn/course/4729热爱机器人和这门学科的朋友很难找到这样的专业课程,内容涉及机器人运动学、动力学、运动规划、编程及设计等...
老白菜 机器人开发
按键的硬件去抖动
1>并联电容法——电容放电延时 73655 SW1未被按下时,P0.20上是高电平,C1右侧是VCC,左侧是0。SW1被按下时,C1两侧会放电延时,C1右侧的正电荷越来越少,直到P0.20上是低电平,SW1抖动,貌 ......
Hellovictoria 模拟电子
求助几篇英文文章
应人之托,想要找几篇关于电子方面的英文文章,1、最好是外行人非工科生可以看懂的电子科普文,2、比较权威的英汉互译。 在此先谢过各位了,手头上有资料的或者有资料来源想法的,给小弟出 ......
logitech66 创意市集
【功放案例】功率放大器在超声辅助聚氨酯微孔阵列冲裁实验中应用
【功放案例】功率放大器在超声辅助聚氨酯微孔阵列冲裁实验中应用 ...
aigtekatdz 测试/测量
数字电源PCB(缩减版)布板完成
1号开始的,搞到现在 137895 137896...
dontium DIY/开源硬件专区
【IoT毕设】机智云物联网平台+arduinoNano控制板+全自动高效智能种树小车
摘要:针对目前人工种树效率低的问题,设计了一种全自助高效智能种树小车。介绍了装置的结构组成,剖析了装置的运动机理。通过SolidWorks三维软件对传动部件进行了结构设计。利用蓝牙模块实现了 ......
毛球大大 机器人开发

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 2823  459  78  1345  2803  42  33  37  41  13 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved