https://www.phoenixcontact.com/us/products/2800195
Type 2 surge protection device - VAL-MS 600DC/2+V-FM - 2800195
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Surge arrester for 2-pos. isolated and grounded DC voltage systems 600 V DC, for DIN rail mounting, 3-pos.
base element (L+, L-, ground) with remote indication contact, three pluggable temperature-monitored varistors,
status message on each connector.
The product photo shows a version
for 1000 VDC
Product Features
Plugs can be checked with CHECKMASTER
With or without floating remote indication contact
Optical, mechanical status indication for the individual arresters
Mechanical coding of all slots
Type 2 consistent plug-in surge arresters
Packing unit
1 pc
320.0 GRM
85363010
Germany
Key commercial data
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
Technical data
Dimensions
Height
Width
Depth
Horizontal pitch
99 mm
53.4 mm
65.5 mm
3 Div.
Ambient conditions
Degree of protection
IP20
09/10/2014 Page 1 / 5
https://www.phoenixcontact.com/us/products/2800195
Type 2 surge protection device - VAL-MS 600DC/2+V-FM - 2800195
Technical data
Ambient conditions
Ambient temperature (operation)
-40 °C ... 80 °C
General
Housing material
Inflammability class according to UL 94
Color
Standards for air and creepage distances
Mounting type
Type
Number of positions
Surge protection fault message
Direction of action
PBT / PA
V0
black
DIN EN 60664-1
DIN EN 61643-11
DIN rail: 35 mm
DIN rail module, two-section, divisible
3
Optical, remote indicator contact
(L+)-PE & (L-)-PE & (L+)-(L-)
Protective circuit
IEC test classification
EN type
Nominal voltage U
N
Maximum continuous operating voltage U
C
Rated load current I
L
Residual current I
PE
Standby power consumption P
C
Max. discharge current I
max
(8/20) µs
Nominal discharge current I
n
(8/20) µs
Voltage protection level U
p
Voltage protection level U
p
(L+) - (L-)
Voltage protection level U
p
(L+/L-) - PE
Residual voltage
Residual voltage (L+) - (L-)
Residual voltage (L+/L-) - PE
Response time
II
T2
T2
600 V DC (Non-load voltage U
OC
)
600 V DC
≤ 80 A DC
≤ 20 µA
≤ 12 mW
40 kA
15 kA
≤ 3 kV (15 kA)
≤ 3.6 kV (20 kA)
≤ 3 kV
≤ 3 kV
≤ 2.5 kV (at 5 kA)
≤ 2.5 kV (at 5 kA)
≤ 2.5 kV (at 5 kA)
≤ 25 ns
PV protective circuit DC side
Short-circuit current rating I
SCPV
80 A
Connection, protective circuit
Connection method
Screw connection
09/10/2014 Page 2 / 5
https://www.phoenixcontact.com/us/products/2800195
Type 2 surge protection device - VAL-MS 600DC/2+V-FM - 2800195
Technical data
Connection, protective circuit
Connection type IN
Connection type OUT
Connection method
Screw thread
Tightening torque
Stripping length
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
AWG conductor cross section
Biconnect screw terminal block
Biconnect screw terminal block
Biconnect terminal block
M5
4.5 Nm
30 lb
f
-in. (UL)
16 mm
1.5 mm²
25 mm²
1.5 mm²
35 mm²
15
2
10 ... 2 (UL)
Remote indicator contact
Switching function
Connection method
Screw thread
Tightening torque
Stripping length
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
AWG conductor cross section
Maximum operating voltage U
max.
AC
Max. operating current I
max
PDT, 1-pos.
MC 1,5/3
M2
0.25 Nm
4 lb
f
-in. (UL)
7 mm
0.14 mm²
1.5 mm²
0.14 mm²
1.5 mm²
28
16
30 ... 14 (UL)
250 V AC
1.5 A AC (250 V AC)
1.5 A DC (30 V DC)
Standards and Regulations
Standards/regulations
DIN EN 61643-11/A11 2007
IEC 61643-1 2005
IEC 60364-7-712 2002
09/10/2014 Page 3 / 5
https://www.phoenixcontact.com/us/products/2800195
Type 2 surge protection device - VAL-MS 600DC/2+V-FM - 2800195
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
27140201
27130801
27130801
27130801
27130805
27130805
27130805
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC000941
EC000941
EC000941
EC000941
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
30212010
39121610
39121610
39121610
39121620
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
09/10/2014 Page 4 / 5
https://www.phoenixcontact.com/us/products/2800195
Type 2 surge protection device - VAL-MS 600DC/2+V-FM - 2800195
Approvals
UL Recognized
cUL Recognized
cULus Recognized
Drawings
Dimensioned drawing
99
45
22,5
Circuit diagram
12
14
11 FM
65,5
58
Phoenix Contact 2014 © - all rights reserved
http://www.phoenixcontact.com
51,5
L+
L–