https://www.phoenixcontact.com/hq/products/2901431
Safety relays - PSR-SPP-230AC/ESAM2/3X1/1X2/B - 2901431
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Safety relay for emergency stop and safety door up to SIL 1, SIL CL 1, Cat. 1, PL c, depending on the
application up to SIL 3, SIL CL 3, Cat. 4, PL e, single-channel operation, 3 enabling current paths, nominal
input voltage of 230 V AC/DC, plug-in spring-cage terminal block
The figure shows a version with a
screw connection
Why buy this product
Up to Cat. 1/PL c according to ISO 13849-1, SILCL 1 according to IEC 62061, SIL 1 according to IEC 61508
Depending on the application, up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
Single-channel control
Basic insulation
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
4046356592178
85371099
1 STK
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
Height
Depth
22.5 mm
112 mm
114.5 mm
Ambient conditions
Ambient temperature (operation)
-25 °C ... 55 °C
11/15/2016 Page 1 / 5
https://www.phoenixcontact.com/hq/products/2901431
Safety relays - PSR-SPP-230AC/ESAM2/3X1/1X2/B - 2901431
Technical data
Ambient conditions
Ambient temperature (storage/transport)
Max. permissible relative humidity (operation)
Max. permissible humidity (storage/transport)
Shock
Vibration (operation)
Maximum altitude
-40 °C ... 85 °C
75 % (on average, 85% infrequently, non-condensing)
75 % (on average, 85% infrequently, non-condensing)
15g
10 Hz ...150 Hz, 2g
≤ 2000 m (Above sea level)
Input data
Nominal input voltage U
N
Input voltage range in reference to U
N
Typical input current at U
N
Voltage at input/start and feedback circuit
Typical response time
Typ. starting time with U
s
Typical release time
Recovery time
Status display
Maximum switching frequency
Max. permissible overall conductor resistance
230 V AC
0.85 ... 1.1
22 mA
~ 24 V DC
50 ms (manual start)
300 ms (automatic start)
300 ms (when controlled via A1 or S11/S12)
20 ms (when controlled via S11/S12)
150 ms (when controlled via A1)
1s
2 x green LEDs
0.5 Hz
50 Ω
Output data
Contact type
Contact material
Minimum switching voltage
Maximum switching voltage
Limiting continuous current
Inrush current, minimum
Maximum inrush current
Sq. Total current
Interrupting rating (ohmic load) max.
3 enabling current paths
1 signaling current path
AgSnO
2
, gold-flashed
10 V AC/DC
250 V AC/DC
6 A (N/O contact)
5 A (N/C contact)
10 mA
6A
72 A
2
144 W (at 24 V DC)
230 W (at 48 V DC)
68 W (at 110 V DC)
88 W (at 220 V DC)
2000 VA (for 250 V AC)
Maximum interrupting rating (inductive load)
48 W (at 24 V DC)
40 W (at 48 V DC)
35 W (at 110 V DC)
11/15/2016 Page 2 / 5
https://www.phoenixcontact.com/hq/products/2901431
Safety relays - PSR-SPP-230AC/ESAM2/3X1/1X2/B - 2901431
Technical data
Output data
33 W (at 220 V DC)
Switching capacity min.
Output fuse
100 mW
10 A gL/gG NEOZED (Enabling current paths)
6 A gL/gG NEOZED (Signaling current paths)
General
Relay type
Mechanical service life
Nominal operating mode
Net weight
Mounting type
Mounting position
Degree of protection
Min. degree of protection of inst. location
Control
Electromechanical relay with forcibly guided contacts in accordance with
EN 50205
Approx. 10 cycles
100% operating factor
99.9 g
DIN rail mounting
any
IP54
IP20
IP54
single-channel
7
Connection data
Connection method
pluggable
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Stripping length
Spring-cage connection
Yes
0.2 mm²
1.5 mm²
0.2 mm²
1.5 mm²
24
16
8 mm
Safety-related characteristic data
Stop category
Safety Integrity Level (SIL)
Designation
Performance level (PL)
Category
Safety Integrity Level Claim Limit (SIL CL)
0
1 (up to SIL 3 depending on the application)
1 (up to SIL 3 depending on the application)
EN ISO 13849
c (up to PL e depending on the application)
1 (up to Cat. 4 depending on the application)
1 (up to SILCL 3 depending on the application)
Standards and Regulations
Shock
Designation
Standards/regulations
Rated insulation voltage
15g
Air clearances and creepage distances between the power circuits
DIN EN 50178/VDE 0160
250 V AC
11/15/2016 Page 3 / 5
https://www.phoenixcontact.com/hq/products/2901431
Safety relays - PSR-SPP-230AC/ESAM2/3X1/1X2/B - 2901431
Technical data
Standards and Regulations
Rated surge voltage/insulation
Degree of pollution
Overvoltage category
Vibration (operation)
4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV
between A1-A2/logic/enabling and signaling current paths)
2
III
10 Hz ...150 Hz, 2g
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Circuit diagram
A1
S11 S12
Circuit diagram
23
33
41
L+
230V
13
24 V DC
K1
S1
Logic
Power
230 V AC
K2
A1
S11 S12
13 23 33 41
K3
PSR-...-230AC/ESAM2/3x1/1x2B
A2
S33 S34 S35
14
24
34
42
A2 S33
S34
S35
K3
K4
S2
M
(N)
Single-channel emergency stop monitoring
Circuit diagram
L+
230V
S1
A1
S11 S12
13 23 33 41
K3
PSR-...-230AC/ESAM2/3x1/1x2B
A2 S33
S34
S35
) (
) (
) (
14 24 34 42
K4
M
K3
K3
K4
K4
M
(N)
Single-channel safety door monitoring
) (
) (
) (
14 24 34 42
K4
M
K3
K4
11/15/2016 Page 4 / 5
https://www.phoenixcontact.com/hq/products/2901431
Safety relays - PSR-SPP-230AC/ESAM2/3X1/1X2/B - 2901431
Approvals
Approvals
Approvals
UL Listed / cUL Listed / EAC / EAC / Functional Safety / cULus Listed
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324
EAC EAC-Zulassung
EAC 7500651.22.01.00244
Functional Safety 01/205/5117.01/16
cULus Listed
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com