28V
DC
MIL-COTS VIPAC
Low Profile, Configurable Power Solution
Features & Benefits
•
DC input: 28V
DC
•
Output voltages:
n
3.3 – 48V
DC
n
40 – 400W total
n
1, 2, or 3 outputs
•
Protective features:
n
Inrush current limiting
n
Input transient protection:
– per MIL-STD-704E/F (M-FIAM5B)
– per MIL-STD-704A/E/F &
MIL-STD-1275A/B/D (M-FIAM9)
n
EMI filtering per MIL-STD-461E
•
Local or remote control
•
Compliant to MIL-STD-810F for
vibration (Method 514.5, Procedure I)
and shock (Method 516.5, Procedure I)
Module environmental stress screening
•
Package style:
n
Low profile mounting options
n
Optional finned heat sink
2 Minis (MVC-Bxxx, MVX-Bxxx)
• 4.96” x 6.8”
(126,0 x 172,7mm)
• 1.4 lbs (640g)
• Single or dual output
• Up to 400W
Configurations
3 Micros (MVC-Axxx, MVX-Axxx)
• 4.96” x 6.8”
• Dual or triple output
(126,0 x 172,7mm)
• 1.4 lbs (640g)
• Up to 300W
Product Highlights
The 28V
DC
MIL-COTS VIPAC family of
power systems is a new class of user-
defined, modular power solutions for the
most demanding military applications. It
incorporates preassembled and tested front
ends (M-FIAM5B or M-FIAM9), Vicor Maxi,
Mini and Micro series DC-DC converters
(H or M-Grade), a choice of output
connections and mechanical platforms. The
28V
DC
VIPAC can be specified with 1, 2 or 3
outputs with voltages as low as 3.3V
DC
to as
high as 48V
DC
and power levels from 40 to
400W per output. Additionally, the wide trim
range of the modules can provide operating
voltages from 500mv to 52.8V. The MIL
VIPAC is available with an input of 28V
DC
in a
variety of packages with profiles as low
as 0.75”.
For additional technical or design information;
or to create a 28V
DC
VIPAC tailored to your
specific requirements using Vicor’s online
configurator, please visit vicorpower.com.
Note:
Weights are for coldplate versions
1 Micro (MVC-Gxxx, MVX-Gxxx)
• 3.15” x 6.8”
(80,0 x 172,7mm)
• 0.9 lbs (411g)
• Single output
• Up to 100W
2 Micros (MVC-Dxxx, MVX-Dxxx)
• 3.15” x 6.8”
(80,0 x 172,7mm)
• 1.0 lbs (457g)
• Single or dual output
• Up to 200W
1 Mini (MVC-Exxx, MVX-Exxx)
• 3.15” x 6.8”
(80,0 x 172,7mm)
• 1.0 lbs (457g)
• Single output
• Up to 200W
1 Maxi (MVC-Fxxx, MVX-Fxxx)
• 3.15” x 9.15”
(80,0 x 234,4mm)
• 1.3 lbs (594g)
• MVC-xxx refers to M-FIAM5B
• MVX-xxx refers to M-FIAM9
• Single output
• Up to 400W
28 V
DC
MIL-COTS VIPAC
Page 1 of 6
Rev 2.4
11/2016
vicorpower.com
800 927.9474
MIL VIPAC General Specifications
Typical at 25 °C, nominal line and load, unless otherwise specified.
INPUT SPECIFICATIONS
Parameter
Min
18
Typ
28
Max
36
0.007
50
Unit
V
DC
A/µF
V
DC
12.5ms per MIL-STD-704E/F, continuous operation
Test conditions AA and FF normal overvoltage transients per
MIL-HDBK-704
Transient immunity (M-FIAM9)
100
250
70
50
MIL-STD-461E
CE101,CE102*
CS101, CS114, CS115, CS116
V
DC
V
DC
V
DC
V
DC
50ms per MIL-STD-1275A/B/D, continuous operation
70µs per MIL-STD-1275A/B/D, continuous operation
20ms per MIL-STD-704A, continuous operation
12.5ms per MIL-STD-704E/F, continuous operation
Notes
Continuous
I
nput voltage
Inrush limiting
Transient immunity (M-FIAM5B)
EMI
Conducted emissions
Conducted susceptibility
*CE102 compliant with loads in excess of 30% of rated output; loads below 30% may need additional input capacitance for compliance.
ENVIRONMENTAL - SYSTEM
Parameter
Dielectric withstand, input to chassis
Operating chassis temperature
H-Grade
M-Grade
Storage temperature
H-Grade
M-Grade
Shock
MIL-STD-810F, Method 516.5, Procedure I
Vibration
MIL-STD-810F, Method 514.5, Procedure I
20-2000Hz at 5g
40g for 15-23ms, 75g for 8-13ms
Min
1500/2121
-40
-55
-55
-65
95
95
125
125
Typ
Max
Unit
V
RMS
/V
DC
°C
°C
°C
°C
Notes
OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Over temperature shutdown
Power sharing accuracy
Programming range
Current limit
Short circuit current
10
115
115
±0.02
±0.002
115
±2
±5
110
Min
Typ
Max
±1
±0.2
±0.005
Unit
%
%
%/°C
°C
%
%
% I
OUT
max
% I
OUT
max
Of nominal voltage. (For trimming below 90% of nominal, a
minimum load of 10% rated power may be required)
Output voltage 95% of nominal
Output voltage <250mV
Notes
V
OUT
nom
Low line to high line; full load
Over operating temperature range
28 V
DC
MIL-COTS VIPAC
Page 2 of 6
Rev 2.4
11/2016
vicorpower.com
800 927.9474
MIL VIPAC SPECIFIC Specifications
ENVIRONMENTAL - MODULES
Altitude
MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level
of 5.6 Grms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 Grms for
1 hour per axis.
Shock
MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock, 40 G’s. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft. MIL-STD-202F,
Method 213B, 60 G’s, 9ms half sine. MIL-STD-202F, Method 213B, 75 G’s, 11ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, Table 513.5-II, Operational, 2-7 G’s, 6 directions.
Humidity
MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH.
Solder Test
MIL-STD-202F, Method 208, 8 hour aging.
MIL-COTS 28V
DC
VIPAC OUTPUT POWER OPTIONS (OUTPUT POWER BASED ON 28V
DC
C NOMINAL INPUT VOLTAGE)
Power (W)
15 V
24 V
100
200
100
100
200
100
100
100
100
200
400
200
200
400
100
200
100
100
200
100
100
100
100
200
400
200
200
400
VIPAC Configuration
Total2
Single micro
1
Dual micro
1
No. of Outputs
Single
Single //
Dual
Dual
3.3 V
75
150
75
150
75
75
75
75
150
300
150
150
264
5V
100
200
100
75
200
100
100
100
100
200
400
200
200
400
12 V
100
200
100
100
200
100
100
100
100
200
400
200
200
400
28 V
100
200
100
100
200
100
100
100
100
200
400
200
200
400
48 V
100
200
100
100
200
100
100
100
100
200
400
200
200
400
100
200
200
100
300
300
Triple micro
1
Triple
Single mini
1
Dual mini
1
Maxi
1
Single
Single //
Dual
Single
200
400
400
400
//
= parallel
1
Lower power modules available – consult website for more information.
2
Derate outpower per chart below.
Derate @ 16 W/V Below 25 Vin
400
Output Power (W)
288
Safe Operating
Area
Transient
~
~
0
10
20
30
40
60
18
25
36
50
Vin
Input Voltage (V)
28V MIL-COTS VIPAC Derating Curve
28 V
DC
MIL-COTS VIPAC
Page 3 of 6
Rev 2.4
11/2016
vicorpower.com
800 927.9474
MIL VIPAC Specific Specifications (Cont.)
MICRO MODULES
Parameter
Efficiency (typ)
Ripple & noise, p-p (typ)
Output power
Output OVP setpoint
Dissipation, standby (typ)
Load reg. (max)
3.3V
79
140
75
4.3
4
0.02
5V
84
100
100
6.25
3.2
0.02
12V
85.8
209
100
14.3
4.4
0.02
15V
89
100
100
17.8
4.6
0.02
24V
88
70
100
28.1
3.6
0.02
28V
89
85
100
32.7
3.3
0.02
48V
87.7
100
100
55.7
3
0.02
Unit
%
mV
Watts
Volts
Watts
±%Vout
20MHz bandwidth
95°C Chassis
Recycle input volt. to restart (1m off)
No load
No load to full load
Notes
Note:
50W Micro models are now available.
MINI MODULES
Parameter
Efficiency (typ)
Ripple & noise, p-p (typ)
Output power
Output OVP setpoint
Dissipation, standby (typ)
Load reg. (max)
3.3V
79
100
150
4.3
5
0.02
5V
82.5
95
200
6.3
5.1
0.02
12V
86
360
200
14.4
4.6
0.02
15V
86.6
250
200
17.8
3.4
0.02
24V
87
260
200
28.5
5.1
0.02
28V
87
180
200
32.8
4.5
0.02
48V
87.5
225
200
55.8
5.4
0.02
Unit
%
mV
Watts
Volts
Watts
±%V
OUT
20MHz bandwidth
95°C Chassis
Recycle input volt. to restart (1m off)
No load
No load to full load
Notes
MAXI MODULES
Parameter
Efficiency (typ)
Ripple & noise, p-p (typ)
Output power
Output OVP setpoint
Dissipation, standby (typ)
Load reg. (max)
3.3V
78.5
75
264
4.3
8
0.02
5V
82
152
400
6.25
6.8
0.02
12V
86.8
70
400
14.3
6.8
0.02
15V
87.5
60
400
17.8
6.3
0.02
24V
88.5
80
400
28.1
11
0.02
28V
87.8
172
400
32.7
6.3
0.02
48V
86.7
58
400
55.8
11.8
0.02
Unit
%
mV
Watts
Volts
Watts
±%V
OUT
20MHz bandwidth
95°C Chassis
Recycle input volt. to restart (1m off)
No load
No load to full load
Notes
Note:
300W (200W @ 3.3V) Maxi models are also available.
28 V
DC
MIL-COTS VIPAC
Page 4 of 6
Rev 2.4
11/2016
vicorpower.com
800 927.9474
MECHANICAL DRAWINGS
Configuration MVC-A / MVX-A
LugMates
Configuration MVC-B / MVX-B
LugMates
Configuration MVC-D / MVX-D
LugMates
Configuration MVC-E / MVX-E
LugMates
Configuration MVC-F / MVX-F
LugMates
Configuration MVC-G / MVX-G
LugMates
0.56
0.56
0.75
0.75
(14,2)
(14,2)
(19,1)
(19,1)
0.56
0.75
(14,2)
(19,1)
0.81
0.81
(20,6) 0.50
(20,6) 0.50
(12,7)
(12,7)
0.81
(20,6) 0.50
(12,7)
1.37
1.37
(34,8)
(34,8)
1.37
(34,8)
0.22
0.22
(5,6)
(5,6)
0.22
(5,6)
0.08
0.08
(2,0)
(2,0)
0.08
(2,0)
0.32
0.32
(8,1)
(8,1)
0.32
(8,1)
1.31
1.31
(33,3)
(33,3)1.00
1.00
(25,4)
1.31 (25,4)
(33,3)
1.00
(25,4)
1.87
1.87
(47,5)
(47,5)
1.87
(47,5)
HEAT SINK OPTIONS
0.56
0.56
0.75
0.75
(14,2)
(14,2)
(19,1)
(19,1)
0.56
0.75
(14,2)
(19,1)
0.81
0.81
(20,6) 0.50
(20,6) 0.50
(12,7)
(12,7)
0.81
(20,6) 0.50
(12,7)
1.37
1.37
(34,8)
(34,8)
1.37
(34,8)
0.32
0.32
(8,1)
(8,1)
0.32
(8,1)
0.22
0.22
(5,6)
(5,6)
0.08
0.08
(2,0)
(2,0)
Coldplate
0.22
0.5” Fin Option
0.08
(2,0)
(5,6)
1.31
1.31
(33,3)
(33,3)1.00
1.00
(25,4)
1.31 (25,4)
(33,3)
1.00
(25,4)
1.87
1.87
(47,5)
(47,5)
1.87
(47,5)
1” Fin Option
Fin spacing and relief are the same
for both Fin options
28 V
DC
MIL-COTS VIPAC
Page 5 of 6
Rev 2.4
11/2016
vicorpower.com
800 927.9474