EMC filters
4-line filters
for installations and systems
Rated current 6 to 125 A
Series/Type:
Date:
B84131
January 2006
EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the
information contained therein without EPCOS’ prior express consent is prohibited.
4-line filters
for installations and systems
Power line filters for 3-phase systems
Rated voltage 440/250 V AC, 50/60 Hz
Rated current 6 to 125 A
Construction
■
4-line filter
■
Metal case
B84131
Features
■
■
■
■
High insertion loss
Compact, cost-optimized design
Easy to install
ENEC10, UL and CSA approval
Applications
■
Power supplies for
– data systems, telecom systems
– medical equipment, industrial installations
– copiers
Terminals
■
Tab connectors 6.3
×
0.8 mm
■
Screw terminals
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current, rated temperature,
climatic category, date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
Circuit diagram
LINE
L1
L2
L3
LOAD
L1’
L2’
L3’
N
N
SSB0338-G
Please read
Cautions and warnings
and
Important notes
at the end of this document.
2
01/06
4-line filters
for installations and systems
Technical data and measuring conditions
Rated voltage V
R
Rated current I
R
Test voltage V
test
Leakage current l
leak
Climatic category (IEC 60068-1)
Approvals
440/250 V AC, 50/60 Hz
Referred to 40
°C
ambient temperature
1770 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
At 400 V AC, 50 Hz
25/085/21 (–25
°C/+85 °C/21
days damp heat test)
EN 133200, UL 1283, CSA C22.2 No.8
B84131
Characteristics and ordering codes
V
R
AC
V
440/250
I
R
A
6
16
25
35
35
50
63
80
125
×
= approval granted
I
leak
mA
<
3.5
<
3.5
<
3.5
<
3.5
<
3.5
<
3.5
<
3.5
<
3.5
<
3.5
Approx.
weight
kg
0.8
1.5
2.3
2.3
2.3
4.5
4.5
12.5
12.5
Ordering code
Approvals
B84131A0006A001
B84131M0003A116
B84131M0001G125
B84131M0001G135
B84131M0001H135
B84131M0002G150
B84131M0002G163
B84131M0004G180
B84131M0004G225
×
×
×
×
–
×
×
×
×
–
×
×
×
×
×
×
–
–
–
×
×
×
×
×
–
–
Please read
Cautions and warnings
and
Important notes
at the end of this document.
3
01/06
4-line filters
for installations and systems
Dimensional drawings
B84131A0006A001 (6 A)
162±1
20±0.5
B84131
135±0.8
46±0.5
L3’ L2’
N’
L1’
30±0.2
L2 L3
L1
N
Tab connector A6.3 x 0.8
M5 (4x)
62±0.5
75±0.2
44±0.2
87±1
LINE
LOAD
SSB0958-X-E
B84131M0003A116 (16 A)
Tab connector A6.3 x 0.8
174.5
149
15.1
104
24.6 24.6 24.6
50
13.5
52.5
44±0.2
M5 x 6
1)
14.5
52
75±0.3
SSB0339-P-E
1) Also suitable for screws with 10-32 UNF thread
Please read
Cautions and warnings
and
Important notes
at the end of this document.
4
01/06
36
13±0.5
4-line filters
for installations and systems
B84131M0001G125, B84131M0001G135/H135 (25 A, 35 A)
14±0.3
23
15
149
M6 and/or
10-32 UNF
B84131
15.1
104
24.6 24.6
24.6
80
52.5±0.8
44±0.2
M5 x 6
1)
14.5
52
75±0.3
SSB0321-L-E
1) Also suitable for screws with 10-32 UNF thread
Type
B84131M0001
G125
G135
H135
I
R
A
25
35
35
Screw thread
M6
M6
10-32 UNF
Tightening torque
Nm
3
3
2
B84131M0002G150, B84131M0002G163 (50 A, 63 A)
Screw thread M6
Tightening
torque 3 Nm
M6
23
141
131
28.6 24.6 24.6 24.6
48.5
44±0.2
M5 x 6
1)
13
65.5
105±0.3
SSB0322-U-E
1) Also suitable for screws with 10-32 UNF thread
Please read
Cautions and warnings
and
Important notes
at the end of this document.
5
01/06
21.8
122
47
33.5