AC/DC SWITCHING POWER SUPPLY
DUAL OUTPUT
120 WATTS
UNIVERSAL INPUT
ZWD120-FWX-W SERIES
General Description
Features
High reliability
Burn-in and hi-pot tested
Flexible DC output combination from 3.3V to 48V
Safety approvals (Pending), EMC compliance
Overload protection
Short-circuit protection
Over temperature protection
Options
Pending certification:
Application
Broad needs
Input
Input Voltage:
Input Voltage Range:
AC100-240V
AC90~264V
TUV
RoHS
Input current:
Frequency:
Frequency Range:
Phase:
Inrush Current:
*1
2.5A(RMS) @ 115VAC
50/60 Hz
47~63Hz
Single
<40A(max.) at AC115VAC
<80A (max.) 230VAC ,
cold start at 25°C
2.5A @ 115VAC
Input Current (RMS)
ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753
Visit us at: www.eta-usa.com
email at: sales@eta-usa.com
Output
Characteristic
Output Voltage
Output Current
Voltage Adjust
Range
Ripple &Noise(max)
Rise time
Hold up time
Models
Unit
Vdc
A
V
mVpp
mS
mS
ZWD120-1224FWX-W
ZWD120-0524FWX-W
ZWD120-0512FWX-W
12
24
5
24
5
12
6
3.5
10
3.5
10
6
±5%
of Rated Output Voltage(at no load within the input range)
120
240
50
240
50
No information available
16 mS at full load and 115VAC nominal line
120
Efficiency
*1
%
80% typical
DIMENSIONS
ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753
Visit us at: www.eta-usa.com
email at: sales@eta-usa.com
Environmental Specification
Operating Temperature*3
Derating Curve
Operating Humidity
Storage Temperature
Storage Humidity
Temperature Coefficient
0 to +40°C ambient derate after 40°C
-2.5%/°C (from 40°C to 60°C), not available at > 60°C
5~95[%RH] (non-condensing)
-40 to +85°C
5~95%/RH(non-condensing)
±0.05%
/
°C
FCC Class B; CISPR22 Class B; EN55022 Class B CE
No information available
Environmental Agencies
Line Conducted Noise [EMI]
Line Harmonic
Distortion/Current
Safety
Cooling
Complies with
UL: UL60950-1
pending
C-UL: 22.2 CSA60950-1 pending
TUV: EN60950-1
pending
CB: IEC60950-1 (Pending)
Convection
Function/Protection
Over current Protection
Over temperature Protection
Short circuit Protection
Remote Sense
Remote Control
Series Operation
Parallel Operation
Input Fuse
MTBF
Overload protected @110% to 160% above following maximum
rating
Automatic shutdown. Located at HS1 with threshold of
88
±4
°C
typical
Auto-recovery
Not available
Not Available
No information
No information
No information
>100,000 hours
available
available
available
at full load and room temperature
Mechanical
Dimension [mm]
76W
×
127L
×
34.5H
Conditions:
*1 Rated input and Rated output
*2 at Output current quick change 25% to 75%
*3 At 100% load (convection cooling)
ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753
Visit us at: www.eta-usa.com
email at: sales@eta-usa.com