Tripp Lite SU10000RT3U 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete
power protection for critical network applications. This system delivers online, double-conversion UPS protection
with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents
unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with
manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to
connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this
UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged
industrial locations.
external battery packs
Hardwire input (3 wire); L6-30R &
L6-20R outlets
Package Includes
SU10000RT3UPM
3U UPS
power module
BP240V10RT3U
external battery
pack
SUPDMB710
Detachable PDU
with manual bypass switch
Four post compatible rack rail kit
(2 sets)
Tower stands for upright tower
configuration
USB, DB9 and EPO Cabling
Features
Tripp Lite SU10000RT3U 10kVA / 10,000VA / 9000 watt on-line, double-conversion UPS system in 6U total
rack/tower configuration (3U UPS power module and 3U external battery pack)
Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no
interruption in output power to connected networking equipment
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Hardwire input; 2 L6-30R and 4 L6-20R outlets
Maximum installed rack depth of only 32.5 in. / 82.6cm
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection
from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as
300V
Supports 50/60Hz operation for worldwide frequency compatibility
Expandable runtime is supported with optional
BP240V10RT3U; BP240V787C-1PH
external battery packs
1/6
Intelligent battery management system with temperature-compensated charging extends battery life
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs
Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and
require replacement
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from
www.tripplite.com/poweralert
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Slot for network management card options
Compatible Tripp Lite UPS management card options
TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD
and
RELAYIOCARD
support a
wide variety of UPS control and monitoring capabilities
Optional
RELAYIOMINI
interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB
interface module)
Supports Emergency Power Off (EPO) via built-in interface
Included rail kit supports 6U 19 inch rackmount installation in 4 post racks
Optional
2POSTRMKITHD
supports installation in 2 post 19 inch racks
Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS
settings for charge level, nominal voltage selection, frequency conversion and other operational parameters
LED / LCD display panel rotates for viewing in rackmount or tower configurations
Network-grade AC surge and noise suppression
Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration
overload conditions
Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
External battery packs are field replaceable and hot swappable
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Output Capacity Details
Power Factor
Crest Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
10000
10
9000
9.0
Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30
seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power;
Double conversion mode is automatically restored as load levels are reduced to 95% or less
0.9
3:1
200V; 208V; 240V
Voltage selection via front panel LCD interface
50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
2/6
Frequency Compatibility Details
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
Output Circuit Breakers
Output AC Waveform (AC Mode)
Output AC Waveform (Battery Mode)
Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to