SU10000RT3U

产品描述UPS - Uninterruptible Power Supplies 10000VASmartOnline
产品类别电源/电源管理   
文件大小481KB,共6页
制造商Tripp Lite
官网地址https://www.tripplite.com/
下载文档 详细参数 全文预览

SU10000RT3U在线购买

供应商 器件名称 价格 最低购买 库存  
SU10000RT3U - - 点击查看 点击购买

SU10000RT3U概述

UPS - Uninterruptible Power Supplies 10000VASmartOnline

SU10000RT3U规格参数

参数名称属性值
产品种类
Product Category
UPS - Uninterruptible Power Supplies
制造商
Manufacturer
Tripp Lite
RoHSDetails
Cable TypeCord Type US
工厂包装数量
Factory Pack Quantity
1
单位重量
Unit Weight
300 lbs

文档预览

下载PDF文档
SmartOnline 208/240V 10kVA 9kW
Double-Conversion UPS, 6U, Extended Run,
Network Card Slot, USB, DB9, Bypass Switch, NEMA
MODEL NUMBER:
SU10000RT3U
Highlights
10kVA / 10,000VA / 9000W
on-line double-conversion UPS;
0.9 power factor
200/208/220/230/240V 50/60Hz
output with economy mode option
Included maintenance bypass
switch enables live replacement
of UPS with zero downtime
6U Rack / Tower compatible;
Hot-swappable power and
battery modules
USB, RS232 & EPO ports; Slot
for Network Management Card
options
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
Description
Tripp Lite SU10000RT3U 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete
power protection for critical network applications. This system delivers online, double-conversion UPS protection
with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents
unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with
manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to
connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this
UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged
industrial locations.
external battery packs
Hardwire input (3 wire); L6-30R &
L6-20R outlets
Package Includes
SU10000RT3UPM
3U UPS
power module
BP240V10RT3U
external battery
pack
SUPDMB710
Detachable PDU
with manual bypass switch
Four post compatible rack rail kit
(2 sets)
Tower stands for upright tower
configuration
USB, DB9 and EPO Cabling
Features
Tripp Lite SU10000RT3U 10kVA / 10,000VA / 9000 watt on-line, double-conversion UPS system in 6U total
rack/tower configuration (3U UPS power module and 3U external battery pack)
Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no
interruption in output power to connected networking equipment
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Hardwire input; 2 L6-30R and 4 L6-20R outlets
Maximum installed rack depth of only 32.5 in. / 82.6cm
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection
from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as
300V
Supports 50/60Hz operation for worldwide frequency compatibility
Expandable runtime is supported with optional
BP240V10RT3U; BP240V787C-1PH
external battery packs
1/6
学C2000精品课程,低价抢购 C2000 LaunchPad!
活动主题:学课程,50元抢C2000开发板! 活动时间:2012年09月27日~12月30日 如何参与? 1、在TI教室注册,获得学员资格; 2、认真学习指定C2000入门课程,并考试; 3、学习考试 ......
EEWORLD社区 微控制器 MCU
74HC138和74HC164一起做数码管和按键
74HC138和74HC164一起做数码管和按键 动态显示做出来有 阴影。那位高手能给修补下。 #include #define uint unsigned int #define uchar unsigned char void delay(uint z); void sendc ......
baidu295210789 51单片机
Xilinx 以太网 1G PCS/PMA 或 SGMII IP LogiCORE™求助
本人最近在使用Xilinx 以太网 1G PCS/PMA 或 SGMII IP LogiCORE™ ,现在有两个时钟gt0_qplloutclk,gt0_qplloutrefclk无法生成,这两个时钟是给IP核内部transceiver用的。我再ISIM仿真中 ......
3008202060 FPGA/CPLD
PCB板layout的12个细节,千万别忽视了!
1、贴片之间的间距333809贴片元器件之间的间距是工程师在layout时必须注意的一个问题,如果间距太小焊膏印刷和避免焊接连锡难度非常大。距离建议如下贴片之间器件距离要求:同种器件:≥0.3mm异 ......
ohahaha PCB设计
武汉招聘_急招硬件工程师
1.硬件工程师(急) 职位要求: 1.本科或以上学历,通信,电子,计算机相关专业,1年以上硬件开发工作经验。大专学历,2年以上经验; 2.熟悉嵌入式系统硬件开发,有32位嵌入式系统硬件电路 ......
岚裳 嵌入式系统
【平头哥Sipeed LicheeRV 86 Panel测评】6-Waft图形界面开发测试(上)
Waft(WebAssembly Framework for Things) 是一个面向 AIoT 的高性能应用研发框架,由阿里工程师研发,基于WebAssembly和自研的渲染引擎技术打造,适用于智能终端的软件应用研发场景,目前已在 ......
DDZZ669 国产芯片交流

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 454  1346  555  570  352  10  28  12  8  57 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved