2−line filters
SIFI−F for normal insertion loss
250 V DC/AC, 50/60 Hz, 3 ... 36 A
Series/Type:
Date:
Version:
B84111F0000*
2008−08−07
07
©
EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures
hereto and the information contained therein without EPCOS’ prior express consent is prohibited.
2−line filters
SIFI−F for normal insertion loss
B84111F0000*
Construction
S
2−line filter
S
Metal case
S
Polyurethane potting (UL 94 V−0)
Features
S
Optimized leakage current
S
Easy to install
S
Compact design
S
Cost−optimized construction
S
ENEC10, UL und cUL approval
c
us
Applications
S
Switched−mode power supplies for
− industrial electronics
− telecom systems
− data systems
S
DC applications
S
Medical engineering Type M
Terminals
S
Filters up to 20A tab connectors 6.3 x 0.8 mm
S
Threaded studs M5 for filters from 25A to 36A
Marking
S
Marking on component:
manufacturer’s logo, ordering code, rated voltage, rated current,
rated temperature, climatic category, date code
S
Minimum marking on packaging: maufacturer’s logo, ordering code,
date code, quantity
Please read and
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 14
B84111-F0000-*-07-7659
2−line filters
SIFI−F for normal insertion loss
B84111F0000*
Typical circuit diagram of B84111F0000B* and B84111F0000G*
LINE
L
LOAD
L’
N
N’
Technical data and measuring conditions of B84111F0000B* and B84111F0000G*
Rated voltage
Rated frequency
Test voltage line to line for 2 s
Test voltage line to case for 2 s
Leakage current
Rated temperature
Climatic category (IEC 60068−1)
V
R
f
R
U
test
U
test
I
leak
T
R
250
50/60
1770
2700
At 230 V AC,
50 Hz
40
25/100/21
°C
V DC/AC
Hz
V DC
V DC
Please read and
Cautions and warnings
and
Important notes
at the end of this document.
Page 3 of 14
B84111-F0000-*-07-7659
2−line filters
SIFI−F for normal insertion loss
B84111F0000*
Typical circuit diagram of B84111F0000M* (for medical applications)
Line
L
Load
L’
N
N’
Technical data and measuring conditions of B84111F0000M* (for medical applications)
Rated voltage
Rated frequency
Test voltage line to line for 2 s
Test voltage line to case for 2 s
Leakage current
Rated temperature
Climatic category (IEC 60068−1)
V
R
f
R
U
test
U
test
I
leak
T
R
250
50/60
1770
2500
At 230 V AC,
50 Hz
40
25/100/21
°C
V DC/AC
Hz
V DC
V AC
Please read and
Cautions and warnings
and
Important notes
at the end of this document.
Page 4 of 14
B84111-F0000-*-07-7659
2−line filters
SIFI−F for normal insertion loss
B84111F0000*
Characteristics and ordering codes for B84111F0000B* and B84111F0000G*
I
R
C
R
L
R
I
leak
Approx.
weight
g
R
typ
Ordering code
Approvals
A
3
6
10
16
20
25
36
mH
2 x 0.1
µF
(X2)
2 x 1.5
2 x 4700 pF (Y2)
2 x 0.1
µF
(X2)
2 x 1.8
2 x 4700 pF (Y2)
mA
mΩ
67
37
12.5
6.8
4.8
4.5
1.6
B84111F0000B030
B84111F0000B060
B84111F0000B110
B84111F0000B116
B84111F0000B120
B84111F0000G125
B84111F0000G136
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
< 0.5 90
< 0.5 90
2 x 0.1
µF
(X2)
2 x 0.87 < 0.5 90
2 x 4700 pF (Y2)
2 x 0.1
µF
(X2)
2 x 0.65 < 0.5 130
2 x 4700 pF (Y2)
2 x 0.1
µF
(X2)
2 x 0.43 < 0.5 130
2 x 4700 pF (Y2)
2 x 0.1
µF
(X2)
2 x 0.66 < 0.5 300
2 x 4700 pF (Y2)
2 x 0.47
µF
(X2)
2 x 10 nF (Y2)
2 x 0.4
<1
300
Characteristics and ordering codes for B84111F0000M* (for medical applications)
I
R
C
R
L
R
I
leak
µA
<2
<2
Approx.
weight
g
90
90
90
130
130
300
300
R
typ
Ordering code
Approvals
A
3
6
10
16
20
25
36
2 x 0.1
µF
(X2)
2 x 0.1
µF
(X2)
2 x 0.1
µF
(X2)
2 x 0.1
µF
(X2)
2 x 0.1
µF
(X2)
2 x 0.1
µF
(X2)
2 x 0.47
µF
(X2)
mH
2 x 1.5
2 x 1.8
mΩ
67
37
12.5
6.8
4.8
4.5
1.6
B84111F0000M030 X
B84111F0000M060 X
B84111F0000M110
B84111F0000M116
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
2 x 0.87 < 2
2 x 0.65 < 2
2 x 0.43 < 2
2 x 0.66 < 2
2 x 0.4
<2
B84111F0000M120 X
B84111F0000M125 X
B84111F0000M136 X
X = approval granted
Please read and
Cautions and warnings
and
Important notes
at the end of this document.
Page 5 of 14
B84111-F0000-*-07-7659