Isolated 2W SM 2:1 Input Single Output DC-DC Converters
Ripple and
Noise
Typ. Max.
mVp/p mVp/p
40
45
45
55
35
50
50
60
60
75
55
70
Efficiency
Min.
%
76
77
81
75
76
78
MTTF
2
MIL.
kHrs
997
987
985
877
795
891
Order Code
1
V
3.3
5
12
3.3
5
12
mA
606
400
167
606
400
167
mA
210
210
200
110
100
100
Typ.
%
78.5
80
83.5
78.5
79.5
81.5
Tel.
kHrs
15886
15761
15761
15230
15517
15638
FEATURES
UL 60950 recognised for reinforced
insulation
ANSI/AAMI ES60601-1, 1 MOPP/ 2 MOOPs
recognised
3kVAC isolation test voltage ‘Hi Pot Test’
Continuous short circuit protection
Output Voltage Trim
Remote on/off pin
No electrolytic capacitors
Operating temperature range -40°C to
105°C with derating
2:1 Input Range
INPUT CHARACTERISTICS
Parameter
Voltage range
24V input types
Input reflected ripple
current
All variants
18
24
4
36
mA p-p
Conditions
12V input types
Min.
9
Typ.
12
Max.
18
Units
V
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Isolation capacitance
Resistance
Conditions
Production tested for 1 second
Qualification tested for 1 minute
All variants
Viso = 1kVDC
Min.
3000
5200
Typ.
Max.
Units
VAC
VDC
pF
GΩ
20
1
OUTPUT CHARACTERISTICS
Parameter
Rated power
Voltage set point accuracy
Line regulation
Load regulation
Conditions
All output types
Min.
10
Typ.
Max.
2
±2
±0.5
±0.5
PRODUCT OVERVIEW
The MTC2 series of miniature surface mount DC-
DC converters offers a single output voltage from
input voltage ranges of 9-18V and 18-36V. The
MTC2 series regulated output voltage is adjust-
able by ±10% and a remote on/off pin is also
included for application power saving.
The MTC2 ideally suited to applications which
include medical. Industrial, telecommunications,
battery powered systems, and process automa-
tion.
Units
W
%
%
%
%
Minimal load to meet datasheet specification
All output types
Low line to high line
All output types
3.3V output types
Peak deviation
(25-75% & 75-25%
swing)
12V output types
1205
2405
Transient response
Settling time (1% V
out
Nom.)
±8
±2
±6
±5
45
80
60
55
75
100
μs
%V
out
1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are
MTC2SXXXXMC-R7 (30 pieces per reel), or MTC2SXXXXMC-R13 (150 pieces per reel)
2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model with nominal input voltage at full load.
All specifications typical at T
A
=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
All enquiries: www.murata-ps.com/support
KDC_MTC2.D01
Page 1 of 13
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
GENERAL CHARACTERISTICS
Parameter
Conditions
1203
1205, 1212
2403
2405
2412
Module on, pin unconnected or open collector floating
3.3V output types
Module off (refer to application notes)
5V & 12V output types
1203, 1205
1212
2403, 2405
2412
Min.
Typ.
285
260
185
225
240
3
2
1.4
1.5
3.9
4.2
Max.
Units
Switching frequency
kHz
V
Remote on/off pin
mW
TEMPERATURE CHARACTERISTICS
Parameter
Operation
Storage
Case temperature above ambient
Conditions
See derating graphs
100% Load, Nom V
IN
, Still Air
Min.
-40
-50
Typ.
Max.
105
125
Units
°C
22
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection (for SELV input voltages)
Remote on/off pin input voltage
1
Input voltage, MTC2 12V input types
Input voltage, MTC2 24V input types
Continuous
12V
25V
40V
1. Provided that external control circuit is the same as application note on page 5.
www.murata-ps.com
All enquiries: www.murata-ps.com/support
KDC_MTC2.D01
Page 2 of 13
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test
voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MTC2 series of DC-DC converters are all 100% production tested at 3kVAC for 1 second and have been qualification tested at 5.2kVDC for 1
minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The MTC2 series has been recognised by Underwriters Laboratory to 250Vrms for Reinforced Insulation.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on
materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be
reduced by 20% from specified test voltage.
SAFETY APPROVAL
ANSI/AAMI ES60601-1
The MTC2 series has been recognised by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of
Operator Protection) based upon a working voltage of 250 Vrms max., between Primary and Secondary. File number E202895 applies.
UL 60950
The MTC2 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250 Vrms with a maximum measured product
operating temperature of 105°C. File number E151252 applies.
Creepage and clearance 5 mm.
FUSING
The MTC2 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below.
Input Voltage, 12V: 0.75A
Input Voltage, 24V: 0.5A
All fuses should be UL recognised and rated to at least the maximum allowable DC input voltage.
RoHS COMPLIANCE, MSL AND PSL INFORMATION
This series is compatible with Pb-Free soldering systems and is also backward compatible with Sn/Pb soldering systems.
The MTC2 series has a process, moisture, and reflow sensitivity classification of MSL2 PSL R7F as defined in J-STD-020
and J-STD-075. This translates to: MSL2 = 1 year floor life, PSL R7F = Peak reflow temperature 245°C with a
limitation on the time above liquidus (217°C) which for this series is 90 sec max. The pin termination finish on this
product series is Gold with Nickel Pre-plate.
www.murata-ps.com
All enquiries: www.murata-ps.com/support
KDC_MTC2.D01
Page 3 of 13
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
CHARACTERISATION TEST METHODS
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less
C2
than 100mΩ at 100 kHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
R1
T1
R2
Y INPUT
+
Output
-
-
R LOAD
APPLICATION NOTES
Maximum Output Capacitance
Maximum output capacitance should not exceed:
Output Voltage
V
3.3
5
12
Maximum Load Capacitance
μF
470
470
220
Start-up times
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 470μF (3.3, 5V outputs) and 220μF (12V outputs), are
shown in the table below. The product series will start into the maximum output capacitance with increased start times.
Typical Wave Form:
Part No.
MTC2S1203MC
MTC2S1205MC
MTC2S1212MC
MTC2S2403MC
MTC2S2405MC
MTC2S2412MC
Start-up times
ms
3
10.5
31
7
12
21
www.murata-ps.com
All enquiries: www.murata-ps.com/support
KDC_MTC2.D01
Page 4 of 13
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
APPLICATION NOTES (Continued)
Control Pin
The MTC2 converters have a shutdown feature which enables the user to disable the converter into a low power state. The control pin connects to the base of an internal
NPN transistor with the converter shut down when the transistor is turned on by an external applied voltage. The converter can also be shut down using a 5V TTL signal (the
unit is OFF for logic High and ON for logic LOW). If the control pin is left open (high impedance), the converter will run normally. A suitable application circuit is shown below.
D
1
(e.g. 1N4001) is necessary for correct operation of the MTC2 when the control
signal is LOW. The recommended drive current I
B
to shut down the MTC2 is 6mA
to 15mA. The value of R
1
can be derived as follows:
R
1
= V
C
- V
D1
- 0.6
I
B
For a switch input:
Calculate the value of R
1
from the above equation given switch voltage V
c
and
chosen current between 6 and 15mA.
For 5V TTL Signal:
Set R
1
to be between 320Ω to 800Ω.
V
IN
Ω
MTC2S
R
2
V
C
or
TTL
-V
IN
R
1
D
1
CTRL
Q
1
Output Voltage Adjustment
The MTC2 series has a trim capability which is located at pin 3, this allows the user to independently adjust the output voltages by ±10%. Adjustments to the output voltages
can be accomplished via a single fixed resistor as shown in Figures 1 and 2. A single fixed resistor can increase or decrease the output voltage depending on its connection.
Fixed resistors should have low temperature coefficient to minimize sensitivity to changes in temperature.
A single resistor connected from the TRIM pin (pin 3) to the +Vout (pin 4), will decrease the output voltage which is shown in figure 1.
A single resistor connected from the TRIM pin (pin 3) to the -Vout (pin 2) will increase the output voltage which is shown in figure 2.
TRIM DOWN
Figure 1. Trim connections to decrease the output voltage
TRIM UP
Figure 2. Trim connections to increase the output voltage
1
+Vin
-Vout
2
1
+Vin
-Vout
2
R
TRIM
TRIM
6
3
TRIM
R
TRIM
6
3
-Vin
CTRL
-Vin
CTRL
5
+Vout
18.64k x V
out
- 52.3k
3.32 - V
out
33.2k x V
out
- 141k
5 - V
out
24.4k x V
out
- 181.388k
12.2087 - V
out
4
5
+Vout
14k x V
out
- 52.3k
3.32 - V
out
23.2k x V
out
- 141k
5 - V
out
12.4k x V
out
- 181.388k
12.2087 - V
out
4
3.3V
out
R
TRIM
=
3.3V
out
R
TRIM
=
5V
out
R
TRIM
=
5V
out
R
TRIM
=
12V
out
R
TRIM
=
12V
out
R
TRIM
=
Accuracy of adjustment is subject to tolerances of resistors and factory adjusted output accuracy. Vout is equal to the desired output voltage.
Logic analyzers are widely used tools in digital design verification and debugging. They can verify the proper functioning of digital circuits and help users identify and troubleshoot faults. They ...[详细]