https://www.phoenixcontact.com/hq/products/1413562
Sample set - SACC-CIM12FS12PL180THRSHSAMPLE - 1413562
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/actuator flush-type socket, 12-pos. with shroud, A-coded, with straight THR solder connection, contact
insert only
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
4055626008318
85366990
1 STK
Technical data
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)
IP67
General
Note
The electrical and mechanical data specified assume that the connector
pair is correctly locked and mounted. If the connector is unlocked and if
there is a danger of contamination, the connector must be sealed using
a protective cap > IP54. Influences arising from litz wires, cables or PCB
assembly must also be taken into consideration.
1.5 A
30 V
0.8 kV
12
≥ 100 MΩ
A - standard
M12 connector IEC 61076-2-101
No
11/13/2016 Page 1 / 3
Rated current at 40°C
Rated voltage
Rated surge voltage
Number of positions
Insulation resistance
Coding
Standards/regulations
Status display
https://www.phoenixcontact.com/hq/products/1413562
Sample set - SACC-CIM12FS12PL180THRSHSAMPLE - 1413562
Technical data
General
Overvoltage category
Degree of pollution
Connection method
Insertion/withdrawal cycles
Torque
Mounting type
III
3
THR solder connection
> 100
3 Nm ... 4 Nm (Installation-side)
PCB mounting
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Sealing material
V0
CuZn
Au
PPA
FKM
Cable
Standards/specifications
Ambient temperature (operation)
M12 connector IEC 61076-2-101
-40 °C ... 85 °C (cable, fixed installation)
-25 °C ... 85 °C (cable, flexible installation)
Standards and Regulations
Standard designation
Standards/regulations
Flammability rating according to UL 94
M12 connector
IEC 61076-2-101
V0
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Schematic diagram
10
1
9
12
8
7
5
6
2
3 11
4
±0,02
Drilling diagram
29,5
,6
°
°
12xØ0,6
±0,05
Ø2,2
8x
±0,02
5
4,5
7,05
±0,02
Pin assignment M12 socket, 12-pos., A-coded,
view female side
3xØ1,4
+0,05
±0,05
Ø5,8
8,5
±0,02
±0,02
Ø1
Drilling diagram
±0,02
37
2x1
20°
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1413562
Sample set - SACC-CIM12FS12PL180THRSHSAMPLE - 1413562
Dimensional drawing
17
2,5
1,5
Ø8,25
M12 socket, straight
Approvals
Approvals
Approvals
EAC
Ex Approvals
Approval details
EAC B.01742
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
Ø0,6
11/13/2016 Page 3 / 3