telecommunications equipment from blackouts, voltage fluctuations and transient surges. Space-saving upright
tower format. Large capacity 3000VA/2100W UPS continuously converts incoming AC to DC, then back to
perfect sine wave AC output at selectable 220/230/240V AC (+/-2%). Removes harmonic distortion, fast
electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS
types. True sine wave output and zero transfer time offers guaranteed compatibility with all equipment types.
Includes 8 C13 outlets. Battery support can be extended through the addition of external battery packs. Includes
Package Includes
SUINT3000XL UPS System
Serial cable
3 C13-to-C14 jumper cables
Owner's manual with warranty
information
slot for internal network management card options, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS
system and power data.
Features
True on-line, double conversion UPS provides pure sine wave AC output at all times
Maintains continuous operation with zero transfer time through blackouts, voltage fluctuations and surges
Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
Corrects brownouts and overvoltages from 175-280V at full load. Input voltage range extends to 80-280V at 50% load or less
3000VA/2100W power capacity with 8 C13 outlets
IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
Standard internal battery set provides 14 min. runtime at half load and 5 min. runtime at full load
Intelligent battery management system extends battery life
Expandable runtime with multiple external battery packs
DB9 serial port for network interface; SNMP compatible
Compatible with Tripp Lite UPS management card options
TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD
and
RELAYIOCARD
Serial port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from
www.tripplite.com/poweralert
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Diagnostic LEDs
1/5
Diagnostic LEDs
Optional
PDUBHV20
bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
3 C13-to-C14 jumper cables included
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Crest Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
Frequency Compatibility Details
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
Included Output Power Cables
Hot-Swap PDU options
Output AC Waveform (AC Mode)
Output AC Waveform (Battery Mode)
3000
3
2100
2.1
0.7
3:1
220V; 230V; 240V
230V default
50 / 60 Hz
Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start
+/- 2%
+/- 10%
+/- 2%
(8) C13
Includes 3 C13 to C14 output power cables
PDUBHV20 (2U / 6 C13, 2 C19 outlets)
Sine wave
Pure Sine wave
INPUT
Rated input current (Maximum Load)
Nominal Input Voltage(s) Supported
UPS Input Connection Type
UPS Input Connection Description
Input Circuit Breakers
Input Phase
13.6A (220V), 13A (230V), 12.5A (240V)
220V AC; 230V AC; 240V AC
C20 inlet
IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall
receptacles
20A
Single-Phase
2/5
BATTERY
Full Load Runtime (min.)
Half Load Runtime (min.)
Expandable Battery Runtime
External Battery Pack Compatibility
DC System Voltage (VDC)
Battery Recharge Rate (Included
Batteries)
Battery Replacement Description
Expandable Runtime
5 min. (2100w)
14 min. (1050w)
Extended runtime supported via optional external battery packs
BP72V15-2U
(limit 1);
BP72V28RT-3U(multi-pack
compatible)
72
Less than 6 hours from 10% to 90%
Hot-swappable, user replaceable batteries
Yes
VOLTAGE REGULATION
Voltage Regulation Description
Overvoltage Correction
Undervoltage Correction
Severe Undervoltage Correction
Online, double-conversion power conditioning
2% output voltage regulation during overvoltages to 280
2% output voltage regulation during undervoltages to 175
2% output voltage regulation during undervoltages to 80 (under 50% load only)
USER INTERFACE, ALERTS & CONTROLS
Switches
Alarm Cancel Operation
Audible Alarm
LED Indicators
2 Switches control off/on power status and alarm-cancel/self-test operation
Power-fail alarm can be silenced using alarm-cancel switch
not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: